34-055-21890

Well Details

Well ID: 34-055-21890
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: PILLA
License Status: Producing
License Date: 2007-07-12
Spud Date: 2007-07-25
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2007-07-30
Well Total Depth: 3960.00 ft
Configuration: Vertical
Latitude: 41.520000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-06-21 Proposed Formations:CLINTON, Issued Date:6/21/2006, Expired Date:6/21/2007 6:00:00 AM, Drilling unit acres:20.83, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2007-07-12 Proposed Formations:CLINTON, Issued Date:7/12/2007, Expired Date:7/11/2008 6:00:00 AM, Drilling unit acres:20.83, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-07-30 RBDMS Rec
Completion Report Received 2008-04-02 RBDMS Rec
Construction Permit Expires 2008-07-11 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-08-13 3767 3799 22
3767 3799 22
3767 3799 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 73233 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 CUTTER EXPLORATION INC 1517.00 271.00 365
2009 CUTTER EXPLORATION INC 6982.00 523.00 365
2010 CUTTER EXPLORATION INC 8697.00 214.00 365
2011 CUTTER EXPLORATION INC 5396.00 227.00 0
2012 CUTTER EXPLORATION INC 2512.00 64.00 366
2013 CUTTER EXPLORATION INC 7134.00 141.00 365
2014 CUTTER EXPLORATION INC 1430.00 0.00 365
2015 CUTTER EXPLORATION INC 5650.00 80.00 365
2016 CUTTER EXPLORATION INC 6779.00 45.00 365
2017 CUTTER EXPLORATION INC 70.00 4439.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 CUTTER EXPLORATION INC Brine 215 365
2009 CUTTER EXPLORATION INC Brine 195 365
2010 CUTTER EXPLORATION INC Brine 98 365
2011 CUTTER EXPLORATION INC Brine 45
2012 CUTTER EXPLORATION INC Brine 60 366
2013 CUTTER EXPLORATION INC Brine 45 365
2014 CUTTER EXPLORATION INC Brine 0 365
2015 CUTTER EXPLORATION INC Brine 40 365
2016 CUTTER EXPLORATION INC Brine 40 365
2017 CUTTER EXPLORATION INC Brine 25 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1127437600 2013-6-6 0:00:0 UP No Violations
-1326322801 2015-1-13 0:00: UP No Violations
-28038620 2007-10-24 0:00 PL No Violations
-412499543 2017-4-4 0:00:0 UP No Violations
0028038620 2007-10-24 Preliminary Restoration No Violations Site is stable, has been ruff graded. Drainage controls are in place. Site needs final grading and seeding.
0267392114 2007-07-26 Drill / Deepen / Reopen No Violations Surface has been set. Operator is working on equipment maintained. 8BBL return on cement. Surface hole was static Operator will break off this afternoon. Possible water well was encountered. There is a 8 PVC pipe behind the rig. Eric thought that it may be a water well. I spoke with Hughie Palmer at the Kokay, he thinks that is a clean out for the drain tile. I called Mike Cutter, he has had all water wells within 300 tested, also homes to the west. He was not aware of the pipe. There are water wells to the east of the site adjacent to RT 306, water wells have steel casings. Straw bails and silt fence need added to the north west corner of the site. I spoke to Hughie regarding the drainage controls. He will have additional controls added.
0275865504 2009-08-21 Production Wells No Violations Man doors are locked. Site is stable. Lease road is stable. Well is in good repair.
0412499543 2017-04-04 UrbanProduction Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. The last reported production for this well shows the records to be up to date. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. Valves on the separator were open and the chart showed production. Tank valves were equipped with flat plugs. The production tank vent stack was plumbed into a 55 gallon charcoal filter and topped with a spark arrestor. Correct lids and hatches were installed on the production tank. The tank battery was diked and fenced with a locked man door. Proper, legible signage was located at the tank battery and the lease access was stable. No violations observed.
0628520405 2007-07-24 Drill / Deepen / Reopen No Violations Operator has cut site. Work pit has been dug, soil is clay no ground water. Silt fence has been installed at the west side of the site. Lease road is stable. Pits are south and the rig will site E/W.
0920390642 2009-05-15 Preliminary Restoration No Violations Man door needs repaired. Bag of diapers need removed. Reclamation is good.
1127437600 2013-06-06 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve was open. The well and tank battery are in good repair and surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The production tanks vent stack is plumbed into a 55 BBL charcoal filter. Then it is plumbed up and capped with a spark arrestor. The production tank is plumbed into the brine tank. The brine tank needs to have a sealable lid or a disconnect the over flow line. The proper identification is on the tank battery. The lease road is stable.
1186061712 2007-08-02 Preliminary Restoration No Violations Pits have been pumped down, will be solidified next week. Safety fence is up. Lease road is stable, drainage controls are in place. Permit sign posted at the entrance of the site.
1219930026 2008-08-27 Preliminary Restoration No Violations Site has been graded and seeded vegetation is established. There has been an overflow in the tank battery, there were a number of diapers in the tank battery, the stone was stained. Diapers have been on site for some time, tank battery has been painted, the diapers were also painted. Called Lynn Strazi and asked what had happened and to have the diapers removed from site. Lynn, stated that when they kicked the well off the brine tank hatch was open and the tank over flowed. Site has been cleaned up, with the exception of the diapers being removed. Well head and tank battery are fenced and gates are locked. Lease road is stable.
1326322801 2015-01-13 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
267392114 2007-7-26 0:00: DD No Violations
275865504 2009-8-21 0:00: PW No Violations
628520405 2007-7-24 0:00: DD No Violations
920390642 2009-5-15 0:00: PL No Violations

For data sources see[9]