If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-21718 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.53,"lon":-81.38,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Chester Township | |
Operator Name: DIVERSIFIED PRODUCTION LLC | |
Well Pad ID: | |
Farm/Lease Name: HAWKEN SCHOOL | |
License Status: Producing | |
License Date: 2005-02-16 | |
Spud Date: 2005-02-15 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2005-02-22 | |
Well Total Depth: 3740.00 ft | |
Configuration: Vertical | |
Latitude: 41.530000 | |
Longitude: -81.380000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1991-08-30 | 18 MUTUAL OIL & GAS CO GeoDate 8/30/91 |
Oil and Gas | 1991-08-30 | Issued Date 8/30/91 Expired Date 8/29/92 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth Proposed Drill Depth |
APP | 2004-11-23 | Proposed Formations:CLINTON, Issued Date:11/23/2004, Expired Date:11/23/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Change of Owner | 2004-11-23 | Operator changed from 18, MUTUAL OIL & GAS CO to 6288, ALLIANCE PETROLEUM CORPORATION |
APP | 2005-02-04 | Proposed Formations:CLINTON/MEDINA, Issued Date:2/4/2005, Expired Date:2/4/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2005-02-15 | PERMIT EXPIRED |
APP | 2005-02-16 | Proposed Formations:CLINTON/MEDINA, Issued Date:2/16/2005, Expired Date:2/16/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2005-02-22 | PERMIT EXPIRED |
Reached Total Depth | 2005-02-22 | PERMIT EXPIRED |
Completion Report Received | 2005-05-31 | PERMIT EXPIRED |
Construction Permit Expires | 2006-02-16 | PERMIT EXPIRED |
Record Last Modified | 2017-02-15 | PERMIT EXPIRED |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2005-08-04 | 3510 | 3533 | 49 |
3510 | 3533 | 49 | |
3510 | 3533 | 49 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 72000 Gal | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | OHIO L & M CO INC | 2243.00 | 0.00 | 208 |
2006 | ALLIANCE PETROLEUM CORPORATION | 8990.00 | 72.00 | 365 |
2007 | ALLIANCE PETROLEUM CORPORATION | 12383.00 | 93.00 | 365 |
2008 | ALLIANCE PETROLEUM CORPORATION | 13105.00 | 82.00 | 365 |
2009 | ALLIANCE PETROLEUM CORPORATION | 11799.00 | 34.00 | 365 |
2010 | ALLIANCE PETROLEUM CORPORATION | 3882.00 | 68.00 | 365 |
2011 | ALLIANCE PETROLEUM CORPORATION | 2283.00 | 0.00 | 365 |
2012 | ALLIANCE PETROLEUM CORPORATION | 8476.00 | 114.00 | 366 |
2013 | ALLIANCE PETROLEUM CORPORATION | 6579.00 | 0.00 | 365 |
2014 | ALLIANCE PETROLEUM CORPORATION | 8683.00 | 96.00 | 365 |
2015 | ALLIANCE PETROLEUM CORPORATION | 6485.00 | 43.00 | 365 |
2016 | ALLIANCE PETROLEUM CORPORATION | 7507.00 | 38.00 | 365 |
2017 | ALLIANCE PETROLEUM CORPORATION | 6804.00 | 44.00 | 365 |
2018 | ALLIANCE PETROLEUM CORPORATION | 8064.00 | 50.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | OHIO L & M CO INC | Brine | 0 | 208 |
2006 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2007 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2008 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2009 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2010 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2011 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 365 |
2012 | ALLIANCE PETROLEUM CORPORATION | Brine | 0 | 366 |
2013 | ALLIANCE PETROLEUM CORPORATION | Brine | 148 | 365 |
2014 | ALLIANCE PETROLEUM CORPORATION | Brine | 141 | 365 |
2015 | ALLIANCE PETROLEUM CORPORATION | Brine | 69 | 365 |
2016 | ALLIANCE PETROLEUM CORPORATION | Brine | 71 | 365 |
2017 | ALLIANCE PETROLEUM CORPORATION | Brine | 99 | 365 |
2018 | ALLIANCE PETROLEUM CORPORATION | Brine | 169 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1740742953 | 2005-5-5 0:00:0 | PL | No Violations | |
-636331611 | 2013-6-10 0:00: | UP | No Violations | |
-897330567 | 2005-2-23 0:00: | DD | No Violations | |
0569402834 | 2007-06-22 | Production Wells | No Violations | On site regarding a complaint from Hawken schools that the man doors on the well and tank battery are not locked. At the time of inspection man doors had locks on them and were locked. Site has debris on it one section of CND pipe and 4.5 pipe. Silt fence is still up in the brush. Rat hole needs topped off. Vegetation was becoming established. Site has two 210 bbl tanks and one plastic 35 bbl tank. |
0636331611 | 2013-06-10 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition. |
0897330567 | 2005-02-23 | Drill / Deepen / Reopen | No Violations | Drilling TD running 4.5 and cementing . |
1044453553 | 2018-07-03 | UrbanProduction Wells | No Violations | During this inspection, the well was equipped with a plunger lift assembly. The gate valve on the tubing and the valve on the 2 inch flow line was open. The well was fenced with a locked man door. Reported production records were current. The tank battery consisted of two 100 BBL production tanks, one 50 BBL poly brine tank, and a mechanical separator. The valves on the separator were open. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery locations. The lease access was stable. No violations observed. |
1276979057 | 2005-02-15 | Drill / Deepen / Reopen | No Violations | location made rig moving on |
1437587163 | 2015-07-22 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The annulus valve is closed. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 50 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition. |
1740742953 | 2005-05-05 | Preliminary Restoration | No Violations | area still needs work |
1763507380 | 2016-11-29 | UrbanProduction Wells | No Violations | I conducted an inspection on this well. The well is equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced with a locked man door. The last reported production records were submitted in 2014 for this well. The tank battery consisted of two 100 BBL production tanks, one 50 BBL poly brine tank, and a mechanical separator. The valves on the separator were open and the chart dated 11/21/2016 showed production. The tank valves were plugged and had the correct lids and hatches. A spark arrestor were installed on the vent stack of the production tank. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery locations. The lease access was stable. |
569402834 | 2007-6-22 0:00: | PW | No Violations |
For data sources see[9]