X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21850

Well Details

Well ID: 34-035-21850
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: NEWELL
License Status: Producing
License Date: 2005-08-19
Spud Date: 2005-09-22
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-09-30
Well Total Depth: 3610.00 ft
Configuration: Vertical
Latitude: 41.530000
Longitude: -81.390000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-08-19 Proposed Formations:CLINTON, Issued Date:8/19/2005, Expired Date:8/19/2006 6:00:00 AM, Drilling unit acres:38.01, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-09-22
Reached Total Depth 2005-09-30
Construction Permit Expires 2006-08-19
Completion Report Received 2008-02-19
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-05-30 3441 3463 45
3441 3463 45
3441 3463 45

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 53000 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 BASS ENERGY CO INC 6291.00 0.00 365
2007 BASS ENERGY CO INC 26592.00 54.00 365
2008 BASS ENERGY CO INC 48948.00 59.00 365
2009 BASS ENERGY CO INC 58636.00 58.00 365
2010 BASS ENERGY CO INC 59984.00 52.00 365
2011 BASS ENERGY CO INC 42732.00 31.00 0
2012 BASS ENERGY CO INC 30872.00 0.00 366
2013 BASS ENERGY CO INC 21884.00 0.00 365
2014 BASS ENERGY CO INC 16773.00 0.00 365
2015 BASS ENERGY CO INC 14542.00 0.00 365
2016 BASS ENERGY CO INC 7436.00 0.00 365
2017 BASS ENERGY CO INC 5429.00 0.00 365
2018 BASS ENERGY CO INC 4049.00 21.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 BASS ENERGY CO INC Brine 75 365
2007 BASS ENERGY CO INC Brine 83 365
2008 BASS ENERGY CO INC Brine 85 365
2009 BASS ENERGY CO INC Brine 137 365
2010 BASS ENERGY CO INC Brine 210 365
2011 BASS ENERGY CO INC Brine 170
2012 BASS ENERGY CO INC Brine 70 366
2013 BASS ENERGY CO INC Brine 90 365
2014 BASS ENERGY CO INC Brine 127 365
2015 BASS ENERGY CO INC Brine 55 365
2016 BASS ENERGY CO INC Brine 50 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 45 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1510933880 2005-9-22 0:00: DD No Violations
-1722305990 2008-5-20 0:00: PL No Violations
-2131624740 2005-9-28 0:00: DD No Violations
0787812154 2017-11-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and associated tank battery, are located on an otherwise undeveloped parcel. At the time of this inspection, fittings and connections at the well and battery were secure and free from leakage or problems. The load-line valves were secure and locked. Tank lids were closed and secure. Secondary containment as intact and free from signs of release, leaks, or problems. The well was in active production. Production reports were current. Bonding and insurance were active and current. I walked and inspected the areas surrounding the wellhead and battery and found no evidence of impacts from leaks, releases, or degradation to the natural greenscape.
0974248593 2006-11-08 Preliminary Restoration No Violations
1395430123 2014-03-21 UrbanProduction Wells No Violations The producing unit is comprised of a wellhead with mechanical plunger lift unit and aboveground storage tank (AST) battery with 1 100-barrel production tank, 1 50-barrel brine tank, mechanical separator, and Dominion metering run. The battery and wellhead are in separate chain-link enclosures, with locks. The unit spacing, signage, process safety equipment are present and good. Secondary containment is present. No problems or violations.
1510933880 2005-09-22 Drill / Deepen / Reopen No Violations
1620704069 2018-06-04 UrbanProduction Wells No Violations I inspected this well as part of routine inspection. At the time of this inspection, the fittings and connections at the wellhead and battery were secure. Tank lids were closed and secure. Load-lines were locked and secure. The chart record was active. Production reports were current. Enclosure gates were locked. I walked the areas surrounding the well and battery and found normal conditions of the extant greenscape.
1722305990 2008-05-20 Preliminary Restoration No Violations
2131624740 2005-09-28 Drill / Deepen / Reopen No Violations Drilling
787812154 2017-11-20 0:00 UP No Violations 0.50
974248593 2006-11-8 0:00: PL No Violations

For data sources see[9]

References