34-035-21820

Well Details

Well ID: 34-035-21820
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: BAKERWELL INC
Well Pad ID:
Farm/Lease Name: OLD HICKORY (HEALY)
License Status: Final Restoration
License Date: 2018-06-18
Spud Date: 2005-02-09
Spud Drilling Contractor: CANTON WELL SERVICE
Final Drill Date: 2005-02-13
Well Total Depth: 3587.00 ft
Configuration: Vertical
Latitude: 41.540000
Longitude: -81.390000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-11-19 Proposed Formations:CLINTON, Issued Date:11/19/2004, Expired Date:11/19/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2005-01-14 Proposed Formations:CLINTON, Issued Date:1/14/2005, Expired Date:1/14/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2005-02-04 Proposed Formations:CLINTON, Issued Date:2/4/2005, Expired Date:2/4/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-02-09 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Completed 2005-02-13 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Reached Total Depth 2005-02-13 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Completion Report Received 2005-11-30 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
APP 2018-06-18 Proposed Formations:CLINTON, Issued Date:6/18/2018, Expired Date:6/17/2020 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-10-01 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Record Last Modified 2019-03-01 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Construction Permit Expires 2020-06-17 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-01-30 3458 3512 68
3458 3512 68
3458 3512 68

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 75000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 BAKERWELL INC 1031.00 0.00 199
2006 BAKERWELL INC 5187.00 59.00 199
2007 BAKERWELL INC 7966.00 45.00 365
2008 BAKERWELL INC 15924.00 81.00 365
2009 BAKERWELL INC 19276.00 40.00 365
2010 BAKERWELL INC 27901.00 66.00 365
2011 BAKERWELL INC 8876.00 0.00 365
2012 BAKERWELL INC 20970.00 96.00 366
2013 BAKERWELL INC 11190.00 38.00 365
2014 BAKERWELL INC 6395.00 0.00 365
2015 BAKERWELL INC 4705.00 0.00 365
2016 BAKERWELL INC 4716.00 0.00 365
2017 BAKERWELL INC 3994.00 67.00 365
2018 BAKERWELL INC 3170.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 BAKERWELL INC Brine 0 199
2006 BAKERWELL INC Brine 42 199
2007 BAKERWELL INC Brine 108 365
2008 BAKERWELL INC Brine 120 365
2009 BAKERWELL INC Brine 104 365
2010 BAKERWELL INC Brine 129 365
2011 BAKERWELL INC Brine 75 365
2012 BAKERWELL INC Brine 101 366
2013 BAKERWELL INC Brine 0 365
2014 BAKERWELL INC Brine 31 365
2015 BAKERWELL INC Brine 30 365
2016 BAKERWELL INC Brine 60 365
2017 BAKERWELL INC Brine 0 365
2018 BAKERWELL INC Brine 156 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1479545266 2017-11-20 0:00 UP No Violations 0.50
-2099566244 2015-9-22 0:00: UP No Violations 0.50
-328695260 2014-3-31 0:00: UP No Violations
0293017759 2018-10-09 Final Restoration No Violations I was on location to evaluate the location for Final Restoration following plugging and abandonment that was completed on 10/1/18. At the time of this inspection, I noted the following: the well plug was stable and showing no signs of leakage or problems at the surface. The tank battery had been dismantled and removed, and the area was re-graded. The areas around the well were to be left ungraded and re-vegetation was being waived per agreement with the landowner. In addition, the access road was to be left in place, and the flow-lines and sales lines left in place per waiver agreement, following evacuation of residual gas and fluids. Final Restoration is passed.
0328695260 2014-03-31 UrbanProduction Wells No Violations The producing unit is comprised of a wellhead with pump jack in a locked chain-link enclosure. The well is producing and I observed no signs of leakage or problems. The aboveground storage tank battery is located near the gated lease road entrance and is in a locked chain-link enclosure. The battery is comprised of 1 100-bareel steel production tank, 1 50-barrel steel brine tank, and separator unit. There is a Dominion metering run outside the battery which appears to be functioning normally. Load-outs are bull plugged and locked, there is secondary containment. I did not observe signs of leaks, spills, or other problems.
0630818904 2010-09-30 Preliminary Restoration No Violations
1362063131 2013-02-25 Preliminary Restoration No Violations The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead consists of a pumpjack system in a 6 chainlink enclosure. There was 80 pounds per square inch (PSI) of pressure at the 4 1/2 casing at the time of my inspection. The tank battery is located 100 feet east of the wellhead, and is comprised of 1 100-barrel (BBL) tank, 1 50-BBL tank, mechanical separator, and associated piping and appurtenances enclosed in an 8 enclosure. The unit is lacking the HB278 production sfaety equipment. I contacted Bakerwell and advised them of the need for the equipment.
1479545266 2017-11-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, fittings and connections at the well and battery were secure and free from leakage or problems. The load-line valves were secure and locked. Tank lids were closed and secure. Secondary containment as intact and free from signs of release, leaks, or problems. The well was in active production. Production reports were current. Bonding and insurance were active and current. I walked and inspected the areas surrounding the wellhead and battery and found no evidence of impacts from leaks, releases, or degradation to the natural greenscape.
1540323176 2018-10-01 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activity being performed by Bakerwell crews. The plugging was completed without problem or incident. The details of the activities may be found in the associated plugging report.
1814917768 2005-09-29 Production Wells No Violations Request from the Mayor of Gates mill said site was not restored and unsightly.Inspection of site found no violation
2099566244 2015-09-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located on an otherwise undeveloped parcel. The area immediately surrounding the well is comprised of woods and meadow grass. Access to the well and battery are afforded by an unpaved, dedicated lease road which enters from County Line Road and travels 300 feet to the unit. At the time of this inspection, the well is in production and records are current. Fittings at the wellhead and battery are secure and free from signs of leakage. Secondary containment is intact and free from staining or other problems. ID signage is present and accurate. The access road is in good condition and well drained. Areas surrounding the wellhead and battery are free from signs of impact relating to production activity.
293017759 2018-10-9 0:00: FR No Violations 1.00
630818904 2010-9-30 0:00: PL No Violations

For data sources see[9]