Well Details

Well ID: 37-059-26906
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Morgan Township
Operator Name: EQT PROD CO
Well Pad ID: 149569
Farm/Lease Name: WHITE 590491
License Status: Active
Spud Date: 2015-08-18
Permit Date: 2015-06-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.988297
Longitude: -80.109383

For data sources see[1][2][3]

Well History

Date Event
2015-06-24 New Permit Application
2015-07-07 Performed Spud Operation
2015-11-20 New Permit Application
2016-04-11 Drilling Completion
2020-01-23 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-08-04 2016-08-13 8,160 10,575,200 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRW-900 FTS International Friction Reducer Hydrotreated Light Distillate 64742-47-8 30 0.00008325 81.864
Oxyalkylated alcohol A Proprietary 5 0.00001388 13.644
Alkyl Alcohol Proprietary 10 0.00002775 27.288
LD-2250 Multi-Chem Group Friction reducer Sodium chloride 7647-14-5 5 0.00337613 3319.83
Ethoxylated alcohol Proprietary 5 0.00337613 3319.83
Fatty nitrogen derived amides Proprietary 5 0.00337613 3319.83
Hydrotreated light petroleum distillate 64742-47-8 30 0.0202568 19919
Polyacrylate Proprietary 30 0.0202568 19919
LD-2550 Multi-Chem Group Additive Inner salt of alkyl amines Proprietary 60 0.00877544 8629.09
Sodium chloride 7647-14-5 10 0.00146257 1438.18
Sand (Proppant) FTS International Proppant Silica Substrate 14808-60-7 100 9.89334 9,728,350.0
MC MX 8-2544 Multi-Chem Group Live Culture - Nitrate Reducing Bacteria Sodium chloride 7647-14-5 100 0.00998798 9821.41
Sodium nitrate 7631-99-4 5 0.000499399 491.071
Hydrochloric Acid (15%) FTS International Acidizing Hydrochloric Acid 7647-01-0 15 0.0197503 19420.9
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 89.7469 88,250,200.0
MC MX 5-3886 Multi-Chem Group Specialty Brine Calcium Nitrate 13477-34-4 100 0.110246 108408
CS-500-SI FTS International Scale inhibitor Ethylene glycol 107-21-1 10 0.00251964 2477.62
CI-150 FTS International Acid corrosion inhibitor Aromatic aldehyde Proprietary 10 0.00002436 23.958
Dimethylformamide 68-12-2 10 0.00002436 23.958
Organic amine resin salt Proprietary 30 0.00007309 71.875
Quaternary ammonium compound Proprietary 10 0.00002436 23.958
Isopropanol 67-63-0 30 0.00007309 71.875
Ethylene glycol 107-21-1 30 0.00007309 71.875

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 EQT PROD CO 0.00 0 0.00 0 0.00 0
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 2,023,128.00 287 0.00 0 0.00 0
2018 EQT PROD CO 1,078,048.00 364 0.00 0 0.00 0
2019 EQT PROD CO 713,944.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 EQT PROD CO Drilling Fluid Waste 130.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Drill Cuttings 722.30 Tons LANDFILL 100419
2015 EQT PROD CO Produced Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Fracing Fluid Waste 260.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Fracturing Fluid Waste 29.24 Bbl RESIDUAL WASTE PROCESSING FACILITY 2014-541
2016 EQT PROD CO Drilling Fluid Waste 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 445.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Synthetic Liner Materials 44.33 Tons LANDFILL 100419
2016 EQT PROD CO Produced Fluid 2.89 Bbl RESIDUAL WASTE PROCESSING FACILITY 2014-541
2016 EQT PROD CO Soil Contaminated by Oil & Gas Related Spills 1.31 Tons LANDFILL 100277
2016 EQT PROD CO Synthetic Liner Materials 2.04 Tons LANDFILL 100277
2016 EQT PROD CO Fracturing Fluid Waste 53.45 Tons LANDFILL 100277
2016 EQT PROD CO Other Oil & Gas Wastes 46.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Drill Cuttings 531.16 Tons LANDFILL 100419
2016 EQT PROD CO Fracturing Fluid Waste 3,330.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Waste Water Treatment Sludge 28.59 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2016 EQT PROD CO Other Oil & Gas Wastes 2.73 Tons LANDFILL 100419
2016 EQT PROD CO Produced Fluid 3,486.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Drilling Fluid Waste 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Produced Fluid 359.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 530.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Other Oil & Gas Wastes 355.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 1,287.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 EQT PROD CO Produced Fluid 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 EQT PROD CO Produced Fluid 4,466.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 2.39 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Other Oil & Gas Wastes 64.55 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 12.85 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Produced Fluid 779.34 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 250.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 12.85 Bbl INJECTION DISPOSAL WELL 34-031-27177
2018 EQT PROD CO Produced Fluid 64.81 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 226.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 41.44 Bbl INJECTION DISPOSAL WELL 34-167-29543
2019 EQT PROD CO Produced Fluid 13.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 129.69 Bbl INJECTION DISPOSAL WELL 34-009-23823
2019 EQT PROD CO Other Oil & Gas Wastes 117.75 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 1,050.61 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 94.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2394049 Primary Facility 2015-07-08 Drilling/Alteration No Violations Noted Set conductor @ 53 ' ( KB ) 7/7/2015.
2406188 Primary Facility 2015-08-13 Routine/Partial Inspection No Violations Noted On 8/13/15, I met with two EQT representatives to take samples from an outside well adjacent to the White Pad.
2407389 Primary Facility 2015-08-18 Drilling/Alteration No Violations Noted Plug 20' conductor and redrilled to 26" conductor @ 40' and cemented (8/14/2015)..
2407397 Primary Facility 2015-08-19 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling on air @ 298' (TD). Setting Water Protection Casing and cementing tonight ( 8/18/2015).
2407399 Primary Facility 2015-08-21 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling on air @ 1016' (TD). Setting Coal Protection Casing and cementing tonight (8/20/2015).
2407522 Primary Facility 2015-08-24 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling on air @ 3517 ' (TD). Setting Intermediate Casing and cementing tonight (8/23/2015).
2430553 Primary Facility 2015-10-23 Administrative/File Review No Violations Noted Administrative review of lab results on 10/23/15 indicates that water supply appears to have been impacted by oil & gas activity. Results and documentation forwarded for final determination.
2440066 Primary Facility 2015-11-23 Routine/Complete Inspection No Violations Noted On 11/23/15, I performed a routine complete inspection of the White Pad and made the following observations:
2469293 Primary Facility 2016-03-24 Administrative/File Review No Violations Noted

On 03/24/16 I conducted an administrative inspection of the White pad in response to a spill by EQT off the White pad. When the rig was being moved on 03/15/16 at 2000 hours a mixture of produced water and drilling mud was spilled onto Bowser Road. EQT has cleaned up the spill in compliance with DEP spill policy.

2471117 Primary Facility 2016-03-14 Incident- Response to Accident or Event No Violations Noted

On 03/14/16 at approximately 1330 hours I conducted an incident response inspection in response to a spill from 03/12/16 at the EQT White pad.

On 03/12/16 at 0305 hours a brine spill occurred to the well pad surface off containment when a truck was loading and the sight glass broke. Initial estimate by the truck driver was 3-5 barrels of fluid, but EQT revised the estimate to 30-40 gallons once EQT staff were able to evaluate the spill. A vacuum truck removed standing fluid and excavation occurred at first light on 03/12/16. An area approximately 30’30’x6” was delineated with the use of a soil conductivity probe and excavated. The impacted material was placed in a lined roll off box for disposal.

2471119 Primary Facility 2016-03-14 Incident- Response to Accident or Event No Violations Noted

On 03/14/16 at approximately 1330 hours I conducted an incident response inspection in response to a spill from 03/12/16 at the EQT White pad.

On 03/12/16 at 0305 hours a brine spill occurred to the well pad surface off containment when a truck was loading and the sight glass broke. Initial estimate by the truck driver was 3-5 barrels of fluid, but EQT revised the estimate to 30-40 gallons once EQT staff were able to evaluate the spill. A vacuum truck removed standing fluid and excavation occurred at first light on 03/12/16. An area approximately 30’30’x6” was delineated with the use of a soil conductivity probe and excavated. The impacted material was placed in a lined roll off box for disposal.

2476629 Primary Facility 2016-04-08 Administrative/File Review No Violations Noted

On 04/08/16 at approximately 0800 hours I conducted an administrative review of the EQT White pad. A spill occurred at the site on 03/12/16 of approximately 30-40 gallons of produced fluid. On 03/14/16 I performed an inspection of the site and the spill area had been excavated and the material placed into a lined roll off box. The area of the spill was then filled with fresh gravel. The spill was cleaned up in compliance with DEP spill policy.

2478774 Primary Facility 2016-04-12 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling on fluid @ 16,779' (TD) .Setting 51/2" Prod. casing and cementing tonight.
2478788 Primary Facility 2016-04-01 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling rig moved on White # 590491 date (4/1/2016).
2503825 Primary Facility 2016-06-13 Drilling/Alteration No Violations Noted Horizontal Marcellus, Moving on site prepairing to start fracing.
2530491 Primary Facility 2016-09-23 Routine/Complete Inspection No Violations Noted On 09/23/14 at approximately 0845 hours I conducted a routine complete inspection of the White Unit. The Act 9 sign was in place and all required documents were present at the site. There were no signs of erosion at the time of inspection. There were no violations observed at the time of inspection.
2538991 Primary Facility 2016-11-16 Incident- Response to Accident or Event In Compliance with Policy Incident response conducted as a result of an operator notification.
2783223 Primary Facility 2018-10-03 Site Restoration No Violations Noted A site restoration inspection was conducted in response to an NOT submittal from EQT.

The Act 9 sign was in place and all required documents were present at the site. The production equipment appeared to be in good condition. PCSM features were installed and appeared to be functioning. The site was well vegetated and meets the requirement of uniform 70% vegetative cover. The NOT is approved.

For data sources see[8]

References