If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-059-25731 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.97825,"lon":-80.069972,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Morgan Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 147688 | |
Farm/Lease Name: A ROSE 590227 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-05-18 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 39.978250 | |
Longitude: -80.069972 |
Date | Event |
---|---|
2011-05-18 | New Permit Application |
2011-07-08 | Performed Spud Operation |
2012-04-20 | New Permit Application |
2013-03-16 | Drilling Completion |
2013-05-18 | Perforation |
2013-05-18 | Performed Stimulation |
2014-04-25 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-05-18 | 2013-05-29 | 7,879 | 7,929,540 | 345,497 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | GSS 660 | Greenfield | Increases the viscosity of the fluid | Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt |
68607-28-3 | 40 | 0.00006000 | 0 |
Methyl Alcohol | 67-56-1 | 15 | 0.00002000 | 0 | ||||
Isopropyl Alcohol | 67-63-0 | 40 | 0.00006000 | 0 | ||||
60% Acetic Acid | Greenfield | Adjusts pH of the fluid | Acetic Acid | 64-19-7 | 60 | 0.00079 | 0 | |
GFR 214 | Greenfield | Reduces friction between pipe and fluid | Sodium Chloride | 7647-14-5 | 10 | 0.00922 | 0 | |
Alcohols, C12-16, Ethoxylated | 68551-12-2 | 7 | 0.00645 | 0 | ||||
Ammonium Chloride | 12125-02-9 | 7 | 0.00645 | 0 | ||||
Petroleum Distillates | 64742-47-8 | 40 | 0.03686 | 0 | ||||
GIC 114 | Greenfield | Prevents iron precipitation | Triethanolamine hydroxyacetate | 68299-02-5 | 20 | 0.00006000 | 0 | |
Ethylene Glycol | 107-21-1 | 20 | 0.00006000 | 0 | ||||
Glycolic Acid | 79-14-1 | 3 | 0.00001000 | 0 | ||||
GBK 101 | Greenfield | Reduces viscosity of the fluid | Ammonium Persulfate | 7727-54-0 | 100 | 0.00126 | 0 | |
Sand | Greenfield | Proppant | Crystalline Silica | 14808-60-7 | 100 | 9.64833 | 0 | |
GSC 940 | Greenfield | Prevents scale deposits | Methyl Alcohol | 67-56-1 | 3 | 0.00068 | 0 | |
DETA-Phosponate | 15827-60-8 | 60 | 0.01641 | 0 | ||||
Ammonium Chloride | 12125-02-9 | 15 | 0.0041 | 0 | ||||
GVA 900L | Greenfield | Adds viscosity to fluid | Solvent Naptha, petroleum, heavy aliph | 64742-96-7 | 60 | 0.00244 | 0 | |
36% HCL | Greenfield | Dissolves cement & minerals in perforations | Hydrochloric Acid | 7647-01-0 | 15 | 0.02121 | 0 | |
GBI 265 | Greenfield | Eliminates bacteria in water sources | Ethanol | 64-17-5 | 4 | 0.0017 | 0 | |
Didecyl dimethyl ammonium chloride | 7173-51-5 | 8 | 0.00339 | 0 | ||||
Alkyl dimethyl benzyl ammonium chloride | 68424-85-1 | 6 | 0.00233 | 0 | ||||
Glutaraldehyde | 111-30-8 | 27 | 0.01145 | 0 | ||||
Water | Greenfield | Carrier | Water | 7732-18-5 | 100 | 90.0408 | 0 | |
GCI 386 | Greenfield | Protects Casing | 1-Octanol | 111-87-5 | 3 | 0.00001000 | 0 | |
N,N-Dimethylformamide | 68-12-2 | 20 | 0.00009000 | 0 | ||||
Ethylene Glycol | 107-21-1 | 40 | 0.00017 | 0 | ||||
Triethyl Phosphate | 78-40-0 | 3 | 0.00001000 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 15 | 0.00007000 | 0 | ||||
Isopropanol | 67-63-0 | 3 | 0.00001000 | 0 | ||||
Cinnamaldehyde | 104-55-2 | 6 | 0.00003000 | 0 | ||||
Ethoxylated Nonylphenol | 68412-54-4 | 5 | 0.00002000 | 0 | ||||
1-Decanol | 112-30-1 | 5 | 0.00002000 | 0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2013-05-18 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 1,061,442.00 | 170 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 1,003,689.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 691,151.00 | 347 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 561,798.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 464,982.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 405,508.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 418,846.00 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | EQT PROD CO | Produced Fluid | 219.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Fracing Fluid Waste | 34,837.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 13,969.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Drilling Fluid Waste | 954.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Fracing Fluid Waste | 26,350.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Fracing Fluid Waste | 1,740.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid | 6,370.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Fracturing Fluid Waste | 32.01 Tons | LANDFILL | 100419 |
2015 | EQT PROD CO | Produced Fluid | 3,252.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Servicing Fluid | 100.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 1,975.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Fracturing Fluid Waste | 55.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Servicing Fluid | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 330.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 1,460.15 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 18.57 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 517.09 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 41.19 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 34.29 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 25.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2014-4 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 125.72 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 861.72 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 12.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2005732 | Primary Facility | 2011-09-21 | Drilling/Alteration | No Violations Noted | E&S ok around perimeter of pad; pits are being cleaned out and relined; 20" conductor set in cellar |
2125864 | Primary Facility | 2012-12-10 | Routine/Complete Inspection | No Violations Noted | SITE COMPLIANT AT TIME OF INSPECTION. |
2145869 | Primary Facility | 2013-02-01 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a rountine inspection. The Operator has 4 Marcellus Wells in production and plans on drilling 3 additional wells on site. The impoundment on site has been re-lined and is empty during this inspection. They are setting up a drill rig on site to begin drilling. The top-hole wells have already been drilled for the second set of wells. |
2151614 | Primary Facility | 2013-02-12 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a routine inspection and conduct sampling below drill site. Samples were taken up and down gradient of the Robison farm pond. Orange water is seeping out the ground down gradient of the A. Rose pad. The Operator was casing and cementing on 1/10/13 at 8:30 pm on the A ROSE 590227 Marcellus Well. |
2162332 | Primary Facility | 2013-04-05 | Routine/Complete Inspection | No Violations Noted | |
2405389 | Primary Facility | 2015-08-26 | Site Restoration | No Violations Noted | On 8/26/15, I performed an NOT inspection for the A. Rose/Robinson/Robison site in response to an NOT request by the operator and made the following observations: |
2638166 | Primary Facility | 2017-09-20 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
For data sources see[9]