34-169-21679

Well Details

Well ID: 34-169-21679
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: East Union Township
Operator Name: MORMACK IND INC
Well Pad ID:
Farm/Lease Name: DRABENSTOTT GERALD
License Status: Plugged and Abandoned
License Date: 2017-08-23
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1972-03-26
Well Total Depth: 3790.00 ft
Configuration: Vertical
Latitude: 40.790000
Longitude: -81.800000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1972-01-25 217 MORMACK IND INC GeoDate 1/25/72
Completed 1972-03-26 GMM UPDATED PLUG STAUS PER PLUG REPORT
Reached Total Depth 1972-03-26 GMM UPDATED PLUG STAUS PER PLUG REPORT
APP 2017-08-23 Proposed Formations:CLINTON, Issued Date:8/23/2017, Expired Date:8/23/2019 12:00:00 PM, Drilling unit acres:47.75, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-11-29 GMM UPDATED PLUG STAUS PER PLUG REPORT
Record Last Modified 2018-07-11 GMM UPDATED PLUG STAUS PER PLUG REPORT
Construction Permit Expires 2019-08-23 GMM UPDATED PLUG STAUS PER PLUG REPORT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3643 3703 0
3643 3703 0
3643 3703 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 MORMACK IND INC 108.00 60.00 0
1985 MORMACK IND INC 0.00 210.00 0
1986 MORMACK IND INC 0.00 418.00 365
1987 MORMACK IND INC 600.00 232.00 365
1988 MORMACK IND INC 0.00 0.00 365
1989 MORMACK IND INC 0.00 0.00 365
1990 MORMACK IND INC 0.00 0.00 365
1991 MORMACK IND INC 0.00 0.00 365
1993 MORMACK IND INC 274.00 266.00 365
1994 MORMACK IND INC 386.00 77.00 365
1995 MORMACK IND INC 560.00 109.00 365
1998 MORMACK IND INC 390.00 39.00 365
1999 MORMACK IND INC 310.00 39.00 365
2000 MORMACK IND INC 195.00 37.00 365
2001 MORMACK IND INC 354.00 114.00 365
2002 MORMACK IND INC 90.00 215.00 365
2003 MORMACK IND INC 245.00 0.00 365
2004 MORMACK IND INC 252.00 244.00 365
2005 MORMACK IND INC 79.00 139.00 365
2006 MORMACK IND INC 102.00 71.00 365
2007 MORMACK IND INC 347.00 0.00 365
2008 MORMACK IND INC 268.00 39.00 365
2009 MORMACK IND INC 62.00 36.00 365
2010 MORMACK IND INC 52.00 35.00 365
2011 MORMACK IND INC 101.00 76.00 0
2012 MORMACK IND INC 72.00 35.00 366
2013 MORMACK IND INC 72.00 38.00 365
2014 MORMACK IND INC 57.00 37.00 365
2015 MORMACK IND INC 46.00 0.00 365
2016 MORMACK IND INC 22.00 0.00 365
2017 MORMACK IND INC 10.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 MORMACK IND INC Brine 65 0
1985 MORMACK IND INC Brine 135 0
1986 MORMACK IND INC Brine 0 365
1987 MORMACK IND INC Brine 35 365
1988 MORMACK IND INC Brine 0 365
1989 MORMACK IND INC Brine 0 365
1990 MORMACK IND INC Brine 0 365
1991 MORMACK IND INC Brine 0 365
1993 MORMACK IND INC Brine 18 365
1994 MORMACK IND INC Brine 28 365
1995 MORMACK IND INC Brine 10 365
1998 MORMACK IND INC Brine 47 365
1999 MORMACK IND INC Brine 0 365
2000 MORMACK IND INC Brine 8 365
2001 MORMACK IND INC Brine 0 365
2002 MORMACK IND INC Brine 18 365
2003 MORMACK IND INC Brine 0 365
2004 MORMACK IND INC Brine 0 365
2005 MORMACK IND INC Brine 0 365
2006 MORMACK IND INC Brine 46 365
2007 MORMACK IND INC Brine 145 365
2008 MORMACK IND INC Brine 50 365
2009 MORMACK IND INC Brine 21 365
2010 MORMACK IND INC Brine 46 365
2011 MORMACK IND INC Brine 69
2012 MORMACK IND INC Brine 25 366
2013 MORMACK IND INC Brine 24 365
2014 MORMACK IND INC Brine 100 365
2015 MORMACK IND INC Brine 0 365
2016 MORMACK IND INC Brine 0 365
2017 MORMACK IND INC Brine 75 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1085456677 2016-4-13 0:00: PW No Violations
-1425467469 2018-2-15 0:00: FR No Violations
-1565813915 2017-7-11 0:00: PW No Violations
-1640108914 2014-5-19 0:00: PW No Violations 0.50
-352138162 2015-6-22 0:00: PW No Violations 0.50
0012028483 2017-11-24 Plug / Plug Back No Violations I was on location to assess the cement top level of the surface plug after plugging. The cement top was not observed from the surface in the 8.625 casing. I lowered a 25 sucker rod downhole and did not tag anything. I spoke with Ed Mack and informed of the deficiency and requested that the well be topped off. Mr. Mack said, they would top it off on 11/28/2017. I e-mail the Wayne County Inspector Allie Oprzadek to inform of the situation.
0352138162 2015-06-22 Production Wells No Violations This is a pumping unit well. There are no evident problems or issues at this time.
1085456677 2016-04-13 Production Wells No Violations Inspected production well on 04/13/2016. The tank battery consists of 1-100 bbl steel tank, 1-1,500 gal plastic tank, and 1-horizontal separator located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
12028483 2017-11-24 0:00 PB No Violations
1313283390 2013-07-15 Production Wells No Violations This is a pump jack well. No apparent problems at time of inspection.
1425467469 2018-02-15 Final Restoration No Violations Visited location on 02/15/2018 to check on the status of location reclamation efforts. The well has been cut-off and buried, and the pits closed, but the tubing, pump jack, and electric box were still present. Will continue to monitor reclamation work.
1511534854 2017-11-24 Plug / Plug Back No Violations I was on location to assess the cement top level subsequent to the previous plugging activities . The cement slurry was previously left in the cellar to allow the well to replenish the volume as needed. Upon inspection I could not visually see the cement top from the surface. I lowered a sucker rod ( 25 length ) into the 8.625 surface casing and did not tag anything. I called Mormack Industries and left a message for the well to be topped off prior to closing the cellar and requested a call back to allow an DOGRM Inspector to be present at the procedure.
1565813915 2017-07-11 Production Wells No Violations Inspected production well on 07/11/2017. The tank battery consists of 1-100 bbl steel tank, 1-1,400 gal plastic tank, and 1-horizontal separator, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. The rods and tubing have been pulled from the well and are laying on racks nearby. No problems were noted at the time of the inspection.
1640108914 2014-05-19 Production Wells No Violations Checking this and other wells in area as result of complaint on another well. This pumping unit well has no apparent troubles at this time.

For data sources see[8]