X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-20761

Well Details

Well ID: 34-169-20761
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Baughman Township
Operator Name: DOMINION EAST OHIO
Well Pad ID:
Farm/Lease Name: BUTZER CLYDE D
License Status: Storage Well
License Date: 1958-06-06
Spud Date: 1958-06-11
Spud Drilling Contractor:
Final Drill Date: 1958-08-05
Well Total Depth: 3867.00 ft
Configuration: Vertical
Latitude: 40.880000
Longitude: -81.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1958-06-11 GL=1015.9, STORAGE
Completed 1958-08-05 GL=1015.9, STORAGE
Reached Total Depth 1958-08-05 GL=1015.9, STORAGE
Record Last Modified 2009-12-11 GL=1015.9, STORAGE

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 R.P. 6 DAYS, FRACED

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 DOMINION EAST OHIO 0.00 0.00 0
2003 DOMINION EAST OHIO 0.00 0.00 0
2004 DOMINION EAST OHIO 0.00 0.00 0
2005 DOMINION EAST OHIO 0.00 0.00 0
2006 DOMINION EAST OHIO 0.00 0.00 0
2007 DOMINION EAST OHIO 0.00 0.00 0
2008 DOMINION EAST OHIO 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 DOMINION EAST OHIO Brine 0 0
2003 DOMINION EAST OHIO Brine 0 0
2004 DOMINION EAST OHIO Brine 0 0
2005 DOMINION EAST OHIO Brine 0 0
2006 DOMINION EAST OHIO Brine 0 0
2007 DOMINION EAST OHIO Brine 0 0
2008 DOMINION EAST OHIO Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-187598400 2014-3-7 0:00:0 SO No Violations 0.50
-212526690 2019-1-10 0:00: SO No Violations
-581473336 2017-4-19 0:00: SO No Violations
-741476074 2015-1-8 0:00:0 SO No Violations 0.50
0187598400 2014-03-07 Storage Well No Violations This storage well has no apparent problems at this time.
0212526690 2019-01-10 Storage Well No Violations Performed annual inspection for Dominion East Ohio Storage Well #2097 on 01/10/2019. The well is equipped with a flanged wellhead with 1-master valve and 2-wing valves, 1-meter with 1-drip and 2-regulators, and 1-100 bbl steel tank located within an earthen dike. Well identification is clearly displayed. A locked security chain around the master valve and one wing valve was present at the time of the inspection. The well is located ~110 from its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz and Gregg Miller (DOGRM Columbus). No other problems were noted at the time of the inspection.
0581473336 2017-04-19 Storage Well No Violations Performed annual inspection for Dominion East Ohio Storage Well #2097 on 04/19/2017. The well is equipped with a flanged wellhead with 1-master valve and 2-wing valves, 1-meter, and 1-100 bbl steel tank, located within an earthen dike. Well identification is clearly displayed. No problems were noted at the time of the inspection.
0741476074 2015-01-08 Storage Well No Violations This gas storage facility has no apparent issues at this time.
1620287726 2020-1-22 0:00: SO No Violations
1621653679 2013-04-15 Storage Well No Violations I inspected Dominion East Ohio Gas storage well #2097 today. The well is located in Section 11, Baughman Township, Wayne County, Ohio. The well is equipped with a master gate valve and a side gate valve with a 3.00 Daniels run plumbed directly into the main pipeline. There is a flow gate valve with a 3.00 line plumbed into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) pickup lines on the storage tank and they are secured with valves and bullhead plugs in place. The storage tank is surrounded by a 2.00 dike and it is of sufficient size to meet the standards of 1501-9-9-05. There are two (2) 1.00 lines from each end of the Daniels run plumbed into a domestic meter run. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. No violations found.
1630374946 2016-03-21 Storage Well No Violations Inspected Dominion East Ohio Storage Well #2097 on 03/21/2016. The tank battery consists of 1-100 bbl steel tank located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a flanged wellhead with 1-master valve. No problems were noted at the time of the inspection.
1946973659 2018-01-22 Storage Well No Violations Performed annual inspection for Dominion East Ohio Storage Well #2097 on 01/22/2018. The well is equipped with a flanged wellhead with 1-master valve and 2-wing valves, 1-meter with a drip and 3-regulators, and 1-100 bbl steel tank located within an earthen dike. Well identification is clearly displayed. No problems were noted at the time of the inspection.

For data sources see[8]

References