Well Details

Well ID: 34-167-24858
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Liberty Township
Operator Name: DEPUY DRILLING CO
Well Pad ID:
Farm/Lease Name: SCHWARTZ JOHN A& FAYE
License Status: Producing
License Date: 1979-07-16
Spud Date: 1979-08-22
Spud Drilling Contractor:
Final Drill Date: 1979-09-25
Well Total Depth: 2685.00 ft
Configuration: Vertical
Latitude: 39.590000
Longitude: -81.270000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-07-16 521 CONSTITUTION PETROLEUM GeoDate 7/16/79
Original Spud 1979-08-22
Completed 1979-09-25
Reached Total Depth 1979-09-25
CO 1992-06-19 4292 SCHWARTZ JOHN A GeoDate 7/16/79
CO 1996-01-09 3936 DePUY DRILLING CO GeoDate 7/16/79
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2373 2537 14
2373 2537 14
2373 2537 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 58000 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 CONSTITUTION PETROLEUM 80.00 1.00 136
1988 CONSTITUTION PETROLEUM 190.00 0.00 218
1989 CONSTITUTION PETROLEUM 64.00 0.00 70
1990 CONSTITUTION PETROLEUM 25.00 0.00 66
1991 CONSTITUTION PETROLEUM 15.00 0.00 139
1992 CONSTITUTION PETROLEUM 0.00 0.00 0
2001 DEPUY DRILLING CO 924.00 21.00 360
2002 DEPUY DRILLING CO 827.00 0.00 350
2003 DEPUY DRILLING CO 653.00 17.00 360
2004 DEPUY DRILLING CO 655.00 12.00 300
2005 DEPUY DRILLING CO 640.00 21.00 360
2006 DEPUY DRILLING CO 678.00 21.00 320
2007 DEPUY DRILLING CO 615.00 51.00 335
2008 DEPUY DRILLING CO 586.00 0.00 350
2009 DEPUY DRILLING CO 511.00 0.00 335
2010 DEPUY DRILLING CO 546.00 22.00 330
2011 DEPUY DRILLING CO 517.00 23.00 300
2012 DEPUY DRILLING CO 624.00 24.00 300
2013 DEPUY DRILLING CO 447.00 24.00 350
2014 DEPUY DRILLING CO 447.00 15.00 330
2015 DEPUY DRILLING CO 521.00 0.00 365
2016 DEPUY DRILLING CO 440.00 0.00 365
2017 DEPUY DRILLING CO 224.00 0.00 365
2018 DEPUY DRILLING CO 597.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 CONSTITUTION PETROLEUM Brine 0 136
1988 CONSTITUTION PETROLEUM Brine 0 218
1989 CONSTITUTION PETROLEUM Brine 0 70
1990 CONSTITUTION PETROLEUM Brine 0 66
1991 CONSTITUTION PETROLEUM Brine 0 139
1992 CONSTITUTION PETROLEUM Brine 0 0
2001 DEPUY DRILLING CO Brine 0 360
2002 DEPUY DRILLING CO Brine 0 350
2003 DEPUY DRILLING CO Brine 0 360
2004 DEPUY DRILLING CO Brine 0 300
2005 DEPUY DRILLING CO Brine 0 360
2006 DEPUY DRILLING CO Brine 0 320
2007 DEPUY DRILLING CO Brine 0 335
2008 DEPUY DRILLING CO Brine 0 350
2009 DEPUY DRILLING CO Brine 0 335
2010 DEPUY DRILLING CO Brine 0 330
2011 DEPUY DRILLING CO Brine 0 300
2012 DEPUY DRILLING CO Brine 0 300
2013 DEPUY DRILLING CO Brine 0 350
2014 DEPUY DRILLING CO Brine 0 330
2015 DEPUY DRILLING CO Brine 0 365
2016 DEPUY DRILLING CO Brine 0 365
2017 DEPUY DRILLING CO Brine 0 365
2018 DEPUY DRILLING CO Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0960263314 2017-09-14 Production Wells Violations Noted The inspection this day revealed that this well is equipped with a pumping unit, a 7 inch diameter open hole surface casing, a 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. The valves on the wellhead are open at the time of inspection. The tank battery for this well is equipped with a 100 barrel steel tank with no proper identification on it. The lease road I took into the well is overgrown with brush and high grass. The well is in violation for having no proper identification on the tank at the time of inspection. All producing leases shall be legibly identified in a conspicuous place on or near the wellhead or storage tank as to owner, lease name, well number, permit number, county, and an emergency telephone number.
2008237347 2017-11-20 Production Wells No Violations The inspection this day revealed that this well is equipped with a pumping unit, a 7 inch diameter open hole surface casing, a 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. The valves on the wellhead are open at the time of inspection. The tank battery for this well is equipped with a 100 barrel steel tank with proper identification on it. The violation on this well has been resolved and the well is now in compliance.
960263314 2017-9-14 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0960263314 US-OH-130981 2017-11-27 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]

References