If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-157-25485 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.44,"lon":-81.65,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Tuscarawas | |
| Municipality: Auburn Township | |
| Operator Name: CNX GAS COMPANY LLC | |
| Well Pad ID: US-OH-000505 | |
| Farm/Lease Name: TROYER | |
| License Status: Plugged Back | |
| License Date: 2011-08-16 | |
| Spud Date: 2012-11-14 | |
| Spud Drilling Contractor: NABORS DRILLING | |
| Final Drill Date: 2012-01-11 | |
| Well Total Depth: 6400.00 ft | |
| Configuration: Vertical | |
| Latitude: 40.440000 | |
| Longitude: -81.650000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| APP | 2011-08-16 | Proposed Formations:TRENTON, Issued Date:8/16/2011, Expired Date:8/15/2013 12:00:00 PM, Drilling unit acres:40.5, Proposed Well Type:ST, Proposed Well Class:STRT |
| Plugged Back | 2012-01-11 | |
| Reached Total Depth | 2012-01-11 | |
| Completion Report Received | 2012-02-28 | |
| Construction Permit Expires | 2013-08-15 | |
| Change of Owner | 2017-11-02 | Operator changed from 8441, CNX GAS COMPANY LLC to 1634, NORTHWOOD ENERGY CORP |
| Change of Owner | 2017-11-28 | Operator changed from 1634, NORTHWOOD ENERGY CORP to 8441, CNX GAS COMPANY LLC - WELL INCORECTELY LISTED ON TRANSFER PROCESSED ON 11/2/2017 THE CORRECT WELL THAT SHOULD HAVE BEEN TRANSFERRED WAS 34-157-2-5485-0100 CORRECTING TRANSFER 11/28/2017 CM. |
| Record Last Modified | 2017-11-28 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2013-02-19 | 8071 | 8312 | 60 |
| 2013-02-15 | 10171 | 10412 | 60 |
| 2013-02-15 | 11071 | 11186 | 60 |
| 2013-02-15 | 10771 | 11012 | 60 |
| 2013-02-15 | 9271 | 9512 | 60 |
| 2013-02-15 | 8971 | 9212 | 60 |
| 2013-02-15 | 9871 | 10112 | 60 |
| 2013-02-15 | 9571 | 9812 | 60 |
| 2013-02-19 | 7771 | 8012 | 60 |
| 11071 | 11186 | 60 | |
| 10771 | 11012 | 60 | |
| 10471 | 10712 | 60 | |
| 10171 | 10412 | 60 | |
| 9871 | 10112 | 60 | |
| 9571 | 9812 | 60 | |
| 9271 | 9512 | 60 | |
| 8971 | 9212 | 60 | |
| 8671 | 8912 | 60 | |
| 8371 | 8612 | 60 | |
| 8071 | 8312 | 60 | |
| 7771 | 8012 | 60 | |
| 7471 | 7712 | 60 | |
| 7171 | 7412 | 60 | |
| 6871 | 7112 | 60 | |
| 6571 | 6812 | 60 | |
| 6571 | 6812 | 60 | |
| 2013-02-15 | 8671 | 8912 | 60 |
| 2013-02-19 | 8371 | 8612 | 60 |
| 2013-02-19 | 6871 | 7112 | 60 |
| 2013-02-19 | 6571 | 6812 | 60 |
| 2013-02-19 | 7471 | 7712 | 60 |
| 2013-02-19 | 7171 | 7412 | 60 |
| 2013-02-15 | 10471 | 10712 | 60 |
For data sources see[3]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 02/25/2012 | 02/25/2012 | 6162.00 | 8,048,643.0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | DWP-204 Clay Control | Calfrac Well Services | Buffer | Formic acid | 64-18-6 | 13.00 | 0.00175000 | |
| DWP-901 | Calfrac Well Services | Gel Breaker | Peroxydisulfuric acid, diammonium salt | 7727-54-0 | 95.00 | 0.00174000 | ||
| DWP-690 | Calfrac Well Services | Friction Reducer Breaker | Hydrogen peroxide | 7722-84-1 | 7.00 | 0.00070000 | ||
| Sand | Calfrac Well Services | Proppant | Sand | |||||
| DWP-612 | Calfrac Well Services | Friction Reduction | Long Chain Polyacrylamide | 0.05 | ||||
| DWP-949 | Calfrac Well Services | Non-Emulsifier/Surfactant | Ethoxylated Alcohols | 40.00 | 0.00545000 | |||
| Organic Acid Salts | 13.00 | 0.00177000 | ||||||
| Organic Acid Salts | 10.00 | 0.00136000 | ||||||
| Organic Acid Salts | 40.00 | 0.00545000 | ||||||
| Isobutyl Ketone | 30.00 | 0.00409000 | ||||||
| Ethoxylated Phenolic Resin | 10.00 | 0.00136000 | ||||||
| DAP-901 | Calfrac Well Services | Scale Inhibitor | Methanol | 67-56-1 | 30.00 | 0.00425000 | ||
| Amine Salt | 5.00 | 0.00071000 | ||||||
| Oxyalkylated Polyamine | 5.00 | 0.00071000 | ||||||
| Phosphoric Acid Ammonium Salt | 5.00 | 0.00071000 | ||||||
| Organic Phosphonate | 30.00 | 0.00425000 | ||||||
| Ammonium chloride | 12125-02-9 | 10.00 | 0.00142000 | |||||
| DWP-913 | Calfrac Well Services | Clay Control | KCl Non-hazardous Substitute | 100.00 | 0.07 | |||
| DWP-944 | Calfrac Well Services | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00196000 | ||
| Polyethylene glycol | 25322-68-3 | 60.00 | 0.00589000 | |||||
| Hydrochloric Acid | Calfrac Well Services | Acid | ||||||
| Hydrochloric acid | 7647-01-0 | 5.00 | 2.11 | |||||
| DWP-111 | Calfrac Well Services | Viscosity Additive | Polysaccharide Suspension | 0.16 | ||||
| Water | Calfrac Well Services | Carrier | Water |
For data sources see[4]
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2012 | CNX GAS COMPANY LLC | Brine | 1284 | 50 |
| 2013 | CNX GAS COMPANY LLC | Brine | 1276 | 366 |
| 2014 | CNX GAS COMPANY LLC | Brine | 991 | 353 |
| 2015 | CNX GAS COMPANY LLC | Brine | 396 | 207 |
| 2016 | CNX GAS COMPANY LLC | Brine | 72 | 45 |
| 2017 | NORTHWOOD ENERGY CORP | Brine | 0 | 335 |
| 2018 | NORTHWOOD ENERGY CORP | Brine | 340 | 310 |
| 2019 | NORTHWOOD ENERGY CORP | Brine | 130 | 4 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1221105353 | 2019-5-10 0:00: | PW | No Violations | 0.30 |
| -1947949619 | 2011-11-15 0:00 | DD | No Violations | |
| -294991748 | 2011-10-11 0:00 | DD | No Violations | |
| -368051641 | 2011-11-4 0:00: | DD | No Violations | |
| -476376067 | 2014-1-30 0:00: | PL | No Violations | 0.50 |
| -620253887 | 2019-4-10 0:00: | PW | No Violations | 0.70 |
| 0294991748 | 2011-10-11 | Drill / Deepen / Reopen | No Violations | Company working on location and lease road. |
| 0368051641 | 2011-11-04 | Drill / Deepen / Reopen | No Violations | Company working on location and lease road. |
| 0476376067 | 2014-01-30 | Preliminary Restoration | No Violations | On the Day of my inspection the site passed preliminary restoration according to 1509.072A. |
| 0611832186 | 2014-01-30 | Preliminary Restoration | No Violations | On the day of my inspection I witnessed that the production records were up to date and the well was properly identified. The well was capable of production and the site passed preliminary restoration according to 1509.072A. |
| 0620253887 | 2019-04-10 | Production Wells | No Violations | Upon arrival on location, I witnessed another GPU unit had been installed back onto the cement pad. The GPU unit had been hooked back up and was back in production. The earthen dike had been put back around the GPU unit. The contaminated area from the fire had been cleaned and new limestone installed around the inside of the earthen dike area. |
| 1221105353 | 2019-05-10 | Production Wells | No Violations | Upon my arrival on location, I witnessed the well was equipped 13.375 inch diameter casing, 9.625 inch diameter casing, 5.5 inch diameter casing, 2.825 inch diameter tubing, rods, and a 640 pumping unit ran with a natural gas motor. The production equipment included two steel 210 barrel tanks, a steel 100 barrel tank, a GPU unit, and a gas combustor unit. The tanks were inside a three-foot, metal containment area and the GPU unit was inside an earthen dike area. The production report was up to date and proper identification was present. |
| 1321379102 | 2011-11-10 | Production Wells | No Violations | Arrived on site and found company building location and lease road. |
| 1341919688 | 2012-01-19 | Drill / Deepen / Reopen | No Violations | I arrived on location and found crew filling frac tanks. No violations this date. |
| 1541633096 | 2018-11-07 | Production Wells | No Violations | Received a phone call from Bill Aronhalt at Northwood Energy. He stated there was a fire at the wellhead of this well. Upon my arrival on location, accompanied by ONDR Emergency Operations Coordinator Jason Blocker, I witnessed that the well was never on fire, but the GPU unit exploded. The explosion caught some of the grass on fire on top of the earthen dike. The fire department put the fire out with water. They will scrape the contaminated dirt up after they remove all the damaged equipment from inside the earthen dike. The well was equipped 13.375 inch diameter casing, 9.625 inch diameter casing, 5.5 inch diameter casing, 2.825 inch diameter tubing, rods, and a 640 pumping unit ran with a natural gas motor. The production equipment included two steel 210 barrel tanks, a steel 100 barrel tank, a GPU unit, and a gas combustor unit. The GPU unit was inside an earthen dike and the tanks were on a plastic liner with 3 foot metal walls. The production report was up to date and proper ident ification was present. |
| 1542116258 | 2018-11-13 | Production Wells | No Violations | |
| 1947949619 | 2011-11-15 | Drill / Deepen / Reopen | No Violations | Arrived on site and found company drilling 30 conductor hole. They will cement in early morning on 11-16-2011. |
| 2123880496 | 2012-01-11 | Plug / Plug Back | No Violations | TD 6400. Schlumberger set 2 plugs thru 5 drill pipe from 6400 (TD) to 5080 (9-5/8 casing seat) this date. Plugged back to drill horizontally. See Plug Back report for details. |
| 611832186 | 2014-1-30 0:00: | PL | No Violations | 0.50 |
For data sources see[7]