34-155-23223

Well Details

Well ID: 34-155-23223
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Warren Township
Operator Name: PAC DEVELOPMENT LLC
Well Pad ID:
Farm/Lease Name: NATALE (SWIW #29)
License Status: Active Injection
License Date: 2013-02-01
Spud Date: 1989-01-31
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1989-02-05
Well Total Depth: 4521.00 ft
Configuration: Vertical
Latitude: 41.260000
Longitude: -80.890000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1988-09-13 2655 KLEESE DEVELOPMENT ASSOCS GeoDate 9/13/88
Oil and Gas 1988-09-13 Issued Date 9/13/88 Expired Date 9/13/89 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04521 Proposed Drill Depth 04521
Original Spud 1989-01-31 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI
Completed 1989-02-05 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI
Reached Total Depth 1989-02-05 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI
Completion Report Received 1990-03-14 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI
APP 2013-02-01 Proposed Formations:NEWBURG, Issued Date:2/1/2013, Expired Date:2/1/2015 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:SWD, Proposed Well Class:SWIW
Annulus Pressure Monitoring Approved 2013-04-30 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI
Plugged Back 2013-04-30 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI
Last Compliance Report 2013-09-12 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI
Construction Permit Expires 2015-02-01 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI
Change of Owner 2016-05-19 Operator changed from 2655, KLEESE DEVELOPMENT ASSOCS to 9678, PAC DEVELOPMENT LLC
Record Last Modified 2017-02-15 PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2013-08-06 3912 4036 304
4226 4331 0
1997-06-29 4226 4331 0
4241 4263 11
3912 4036 304
3912 4036 304
2006-09-11 4241 4263 11

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 104850 Gal 0 SLICKWATER FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 PIN OAK PETROLEUM INC 10969.00 124.00 190
1990 KLEESE DEVELOPMENT ASSOCIATES 21120.00 114.00 365
1991 KLEESE DEVELOPMENT ASSOCIATES 12495.00 49.00 365
1992 KLEESE DEVELOPMENT ASSOCIATES 15168.00 100.00 365
1993 KLEESE DEVELOPMENT ASSOCIATES 18791.00 76.00 365
1994 KLEESE DEVELOPMENT ASSOCIATES 15515.00 76.00 365
1995 KLEESE DEVELOPMENT ASSOCIATES 7702.00 0.00 274
1996 KLEESE DEVELOPMENT ASSOCIATES 10442.00 29.00 274
1997 KLEESE DEVELOPMENT ASSOCIATES 10831.00 0.00 274
1998 KLEESE DEVELOPMENT ASSOCIATES 6141.00 0.00 365
2001 KLEESE DEVELOPMENT ASSOCIATES 7456.00 0.00 274
2002 KLEESE DEVELOPMENT ASSOCIATES 8230.00 0.00 365
2003 KLEESE DEVELOPMENT ASSOCIATES 7292.00 0.00 365
2004 KLEESE DEVELOPMENT ASSOCIATES 5639.00 0.00 365
2005 KLEESE DEVELOPMENT ASSOCIATES 5764.00 0.00 365
2006 KLEESE DEVELOPMENT ASSOCIATES 5096.00 49.00 365
2007 KLEESE DEVELOPMENT ASSOCIATES 6059.00 0.00 365
2008 KLEESE DEVELOPMENT ASSOCIATES 5647.00 24.00 365
2010 KLEESE DEVELOPMENT ASSOCIATES 6854.00 16.00 365
2011 KLEESE DEVELOPMENT ASSOCIATES 5813.00 0.00 365
2012 KLEESE DEVELOPMENT ASSOCIATES 6064.00 12.00 366
2013 KLEESE DEVELOPMENT ASSOCIATES 3230.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 PIN OAK PETROLEUM INC Brine 0 190
1990 KLEESE DEVELOPMENT ASSOCIATES Brine 0 365
1991 KLEESE DEVELOPMENT ASSOCIATES Brine 0 365
1992 KLEESE DEVELOPMENT ASSOCIATES Brine 28 365
1993 KLEESE DEVELOPMENT ASSOCIATES Brine 78 365
1994 KLEESE DEVELOPMENT ASSOCIATES Brine 15 365
1995 KLEESE DEVELOPMENT ASSOCIATES Brine 0 274
1996 KLEESE DEVELOPMENT ASSOCIATES Brine 13 274
1997 KLEESE DEVELOPMENT ASSOCIATES Brine 38 274
1998 KLEESE DEVELOPMENT ASSOCIATES Brine 17 365
2001 KLEESE DEVELOPMENT ASSOCIATES Brine 0 274
2002 KLEESE DEVELOPMENT ASSOCIATES Brine 0 365
2003 KLEESE DEVELOPMENT ASSOCIATES Brine 0 365
2004 KLEESE DEVELOPMENT ASSOCIATES Brine 0 365
2005 KLEESE DEVELOPMENT ASSOCIATES Brine 0 365
2006 KLEESE DEVELOPMENT ASSOCIATES Brine 0 365
2007 KLEESE DEVELOPMENT ASSOCIATES Brine 35 365
2008 KLEESE DEVELOPMENT ASSOCIATES Brine 0 365
2010 KLEESE DEVELOPMENT ASSOCIATES Brine 15 365
2011 KLEESE DEVELOPMENT ASSOCIATES Brine 47 365
2012 KLEESE DEVELOPMENT ASSOCIATES Brine 0 366
2013 KLEESE DEVELOPMENT ASSOCIATES Brine 892 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1027744807 2013-7-15 0:00: SW No Violations
-1040400902 2018-7-23 0:00: SW No Violations 0.80
-1047860150 2015-12-3 0:00: SW No Violations 0.50
-1062241582 2020-4-30 0:00: SW No Violations
-1092641971 2020-3-31 0:00: SW No Violations 0.80
-1130975413 2013-9-5 0:00:0 SC No Violations
-1272373844 2017-1-5 0:00:0 SW No Violations
-1334462209 2019-11-18 0:00 SW No Violations 0.50
-139260464 2019-1-14 0:00: SW No Violations 0.70
-1469682633 2018-3-22 0:00: SW No Violations 0.50
-1505371364 2020-3-26 0:00: SW No Violations 5.00
-1518410216 2014-5-16 0:00: SW No Violations
-1590048479 2013-12-17 0:00 SW No Violations
-1601143129 2013-4-18 0:00: SW No Violations
-1603238546 2013-9-16 0:00: SC No Violations
-1607249832 2013-4-23 0:00: SW No Violations
-1633606046 2014-6-10 0:00: SW No Violations
-1725618463 2017-2-15 0:00: SW No Violations
-1793764185 2017-5-4 0:00:0 SW No Violations
-1852366862 2017-6-29 0:00: SW No Violations 0.30
-1870941006 2013-9-5 0:00:0 SW No Violations
-1969738249 2019-11-4 0:00: SW No Violations 1.00
-1978427379 2019-7-31 0:00: SW No Violations 0.30
-2029611566 2013-4-13 0:00: SW No Violations
-2110500869 2020-9-1 0:00:0 SW No Violations
-2145436391 2013-4-9 0:00:0 SW No Violations
-238973756 2020-4-29 0:00: SW No Violations 0.50
-277206063 2016-9-15 0:00: SW No Violations
-326682551 2013-8-19 0:00: SW No Violations
-433520653 2020-5-6 0:00:0 SW No Violations
-444706972 2017-1-30 0:00: SW No Violations
-463295380 2015-4-25 0:00: SW No Violations
-471360909 2020-3-3 0:00:0 SW No Violations 1.30
-535038254 2020-5-6 0:00:0 SW No Violations 0.40
-577697694 2013-10-15 0:00 SW No Violations
-630573903 2015-9-4 0:00:0 SW No Violations
-810745973 2020-8-21 0:00: SW No Violations 0.50
-839349100 2019-2-11 0:00: SW No Violations
-953009995 2013-4-11 0:00: SW No Violations
-973539868 2013-4-29 0:00: SW No Violations
0066647115 2019-03-13 Salt Water Injection Well Violations Noted I found the injection well not in operation during my inspection. Upon gauging the injection tubing, the reading was above the maximum allowable pressure at 1,090 psi. There was a facility operator on location. I observed no leaks or spills. The proper identification sign is posted. I spoke to the facility operator and instructed him to not operate the injection well until the pressure is below the maximum allowable pressure. A follow-up inspection will be conducted.
0103291057 2015-06-03 Salt Water Injection Well No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
0134038713 2017-02-28 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 3rd, & 4th quarters of 2016. Please submit the appropriate reports by March 14, 2017 REPORTS RECEIVED 3/6/2017.
0139260464 2019-01-14 Salt Water Injection Well No Violations I was on location to inspect the injection well. I found the access road to the injection well blocked by a vehicle in front of the closed and locked access road gate. I instructed the facility operator to have the vehicle removed and not to block access to the injection well. The facility is in good repair. There was a AIM Services brine truck (#25-564) and a Spirit Services brine truck (#25-562) off-loading on location with the proper identification displayed.
0184094544 2015-12-14 Salt Water Injection Well No Violations I was on location in reference to complaint ID 5197. At this time, the identification sign had not been corrected. I spoke with Joe Townsend, Safety Coordinator for KDA, on location. Mr. Townsend stated the new sign had been order and due to arrive this week.
0225278534 2013-07-01 Salt Water Injection Well No Violations The flow line was pressure tested, using 1080 psi. of pressure. During fifteen minute test period, 10 psi. loss was observed. The line will not be buried. There were no apparent leaks detected.
0244384091 2014-07-25 Salt Water Injection Well Violations Noted An inspection found the well exceeding the maximum allowable injection pressure. The well tender was instructed to slow the pump rate, lowering the pressure by more than 15 psi. on the tubing. The well owner was instructed to put a minimum pressure of 200 psi. on the tubing/casing annulus.
0277206063 2016-09-15 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0314238672 2017-09-20 Salt Water Injection Well No Violations I was on location to inspect the injection well. The well is surrounded by a locked wooden fence. An identification sign is posted on the fence. The UIC facility and diked tank battery is in good repair. There is an identification posted on the facility office building. There are no violations at this time.
0326682551 2013-08-19 Salt Water Injection Well No Violations No violations were found at the time of my inspection.
0444706972 2017-01-30 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations at the time.
0463295380 2015-04-25 Salt Water Injection Well No Violations The purpose of this inspection was to follow-up on a compliance notice for exceeding the maximum allowable injection pressure. The injection pressure was below the maximum allowed. A pressure shut-off switch was installed on the injection line. A meter was recording, both tubing pressure and annular pressure, on a chart. The well was in compliance and allowed to operate.
0519826056 2018-01-12 Salt Water Injection Well No Violations I was on location to inspect the UIC facility. I found the injection well pressure over the maximum allowable pressure by 20 psi. The injection line to the wellhead and gravel around the injection well had oil residue. An identification sign is posted at the well and facility. The fence around the well is secure with a lock. I told the facility operator to immediately reduce the pressure. The facility operator stated the injection has been shut down due to the pressure and the area around the well impacted by the oil residue will be cleaned up. A follow-up inspection will be conducted by 1/18/2018.
0530076386 2016-05-17 Salt Water Injection Well No Violations At the time of my inspection, I found the injection well in production. The well is in good repair. There is a locked wooden fence around the well. An identification sign is posted at the well. The tank battery has nine storage tanks. The off-loading area and pump house are in good repair. The access road is in stable condition with a gate at the entrance.

The equipment on the site consists of the following:


1 Injection well

0530723686 2013-04-10 Salt Water Injection Well No Violations The cement plug was tagged at 4122 feet. The casing and cement plug were pressure tested. The test failed.
0577697694 2013-10-15 Salt Water Injection Well No Violations There were no violations at the time of inspection.
0595023586 2015-02-13 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0612037210 2014-03-18 Salt Water Injection Well No Violations The annulus maybe frozen, preventing an accurate reading. There were no violations at the time of inspection.
0630573903 2015-09-04 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0695457503 2015-12-21 Salt Water Injection Well No Violations I was on location to inspect the injection well and facility. The emergency contact information on the main identification sign located above the office has been corrected. At this time, there are no violations.
0839349100 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 2nd & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
0843563620 2015-01-12 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0873863014 2013-09-03 Surface Facility Construction No Violations Seven inches of concrete was poured over emergency containment vaults.
0953009995 2013-04-11 Salt Water Injection Well No Violations A bridge plug was set, in the well, just above the cement plug. A cement bond log was ran, which showed the top of cement, behind the 4-1/2 inch casing, at 3690 feet.
0973539868 2013-04-29 Salt Water Injection Well No Violations A contractor was drilling out a remedial cement plug within the 4-1/2 inch casing.

My inspection of the well site found no violations.

0986623649 2014-11-20 Brine Hauler No Violations PERFORMED FIELD AUDIT ON BRINE TRUCKS. WITNESSED 1 KEYSTONE CLEARWATER SOLUTIONS TRUCK (UIC # 25-579) LABELED PROPERLY AND APPROVED TO DISPOSE AT THIS SITE. NO TRUCK VIOLATIONS FOUND.
1027744807 2013-07-15 Salt Water Injection Well No Violations The well was in compliance at the time of inspection.
1032090226 2019-02-25 Salt Water Injection Well No Violations I was on location to assess Compliance Notice #124404230. I found the injection well under the maximum allowable pressure. An identification sign is posted. There are no further violations at this time.
103291057 2015-6-3 0:00:0 SW No Violations
1040400902 2018-07-23 Salt Water Injection Well No Violations I found the injection well in operation during my inspection. I observed the fitting coming off of the wellhead has a slow leak and impacting gravel around other surface. There is a locked wooden fence around the wellhead. Identification signs are posted. I instructed the facility operator to repair the leaking fitting and remove all of the impacted gravel.
1045458556 2014-01-31 Salt Water Injection Well No Violations There were no violations at the time of inspection.
1047860150 2015-12-03 Salt Water Injection Well No Violations I was on location in reference to complaint ID 5197. During my inspection, I found an identification sign posted above a window on the office building next to the tank battery. The emergency contact and number were incorrect. There is an identification sign posted at the well with the name and permit number. A locked, wooden fence surrounds the well. I instructed KDA to correct the emergency contact and number immediately. Next, I called and left a message with Ms. Beiersdorfer for a return call. A follow-up inspection will be conducted by 12/10/2015.
1089262642 2017-02-01 Salt Water Injection Well No Violations The injection well and surface facility were inspected the previous day. There was a difference of 5 pounds per square inch (psi.) between the tubing pressure and tubing/casing annular pressure.

The purpose of this inspection was to ensure that the well had mechanical integrity. On this day, there was a difference of 40 psi. between the two pressures. Jason Caldwell was instructed to increase the difference to at least 500 psi. by lowering the annular pressure.

1093948407 2015-04-24 Salt Water Injection Well No Violations The purpose of this inspection was to follow-up on a compliance notice issued the day before. On 4/23/15, the well was operating 40 psi. over the maximum allowable injection pressure. At the time of this inspection, the well was operating at 50 psi. over the maximum allowable injection pressure. Matt Kleese was ordered to shut down the injection operation. He was instructed to equip the well with a pressure shut-off switch and an approved form of continuous pressure monitoring.
1130975413 2013-09-05 Surface Facility Construction No Violations The concrete was being poured for a pad under the 400 barrel storage tanks.
1134873528 2020-5-21 0:00: SW No Violations 0.30
118143191 2020-4-27 0:00: SW No Violations
1202480719 2013-04-26 Salt Water Injection Well No Violations I witnessed the packer installation. The mechanical integrity test could not be done. A leak in the casing will have to be located.
1239185605 2019-04-29 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019.
1244042300 2019-02-22 Salt Water Injection Well Violations Noted I found the injection well not operating during my inspection. Upon gauging the injection well, the reading for the injection tubing was above the maximum allowable pressure at 1,090 psi. I spoke with facility operator and instructed him to cease all injection operations until the pressure at the injection well has dropped below the maximum allowable pressure. The facility operator stated the injection well has been shut down all morning. There was an AIM brine truck and a CES brine truck off-loading on location with the proper UIC numbers (#25-564 and #25-423) and company information displayed. A follow-up inspection will be conducted by 2/25/2019.
1244544426 2014-12-04 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1252236703 2020-5-18 0:00: SW No Violations 1.00
1272373844 2017-01-05 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The pump was operating at the time.

There were no violations found.

1294841667 2020-1-22 0:00: SW No Violations 0.40
134038713 2017-2-28 0:00: SW No Violations
1346583843 2014-09-11 Salt Water Injection Well No Violations An inspection of the well and injection facility found no violations.
1348498963 2012-09-11 Production Wells No Violations The well owner has applied to convert the well from production to saltwater injection. The well site was inspected as part of a field review. There are no water wells within 300 feet of the well and proposed facility location. The well is located within what may be wetlands. Additional permit requirements may be warranted.
1352705607 2019-11-14 0:00 SW No Violations 0.40
1372784403 2013-04-19 Salt Water Injection Well No Violations A pressure test was performed, with a pressure of 1295 psi. placed on the casing. During the 15 minute test period, a 50 psi. or 3.9% loss was observed. The test passed with a loss less than 5%.
1377566923 2013-08-23 Surface Facility Construction No Violations The turning lane and entrance is complete. Surface facility construction was started. There were no problems at the time.
1377618488 2013-07-12 Salt Water Injection Well Violations Noted My inspection was accompanied by Andrew Adgate. The well was found operating over the maximum allowable injection pressure.

The operator was instructed to shut down, decrease the tubing pressure, and install a pressure shut-off switch.

1378656235 2014-08-15 Salt Water Injection Well No Violations An inspection of the well and injection facility found no violations.
1428691037 2015-04-08 Salt Water Injection Well No Violations I inspected this salt water injection well as a general, routine status check. The facility is comprised of an aboveground storage tank (AST) battery with 9 210-barrel steel tanks in a common containment pad. Adjacent to the tank impoundment, is a combined maintenance/office/control room. The wellhead is located 320 feet behind (southwest) of the control building. Unloading is executed by attaching 4-inch flex-hose to cam-lock fittings at the pit area and fluids are drained into this open-topped, cement-sided impoundment structure which is underlain by a series of pre-cast cement tank vaults. Fluids are moved from the pit into the battery tanks via fluid pumps with flexible hoses. Secondary containment at the battery is comprised of both cement walls and berms. The berms consist of gravel-ballasted flexible liner over coarse-granular or gravel dike. Areas surrounding the AST impoundment and control building consist of parking and drive areas which are gravel and/or cinder-paved. The areas beyond the footprint of the facility are comprised of woods and low-lying marshy and bog-type terrain. I inspected the low-lying marshy and bog areas surrounding the facility and did not observe any sheens, free-oil, stressed vegetation, or other signs of leakage or spills. I observed the drainage culvert along the roadway at the entrance to be similarly free from staining, sheens, stressed vegetation, or other signs of impact. The well is located in a locked, board-on-board enclosure in a small clearing which is accessed via an unpaved road which travels south behind the facility. I observed connections and fittings at the wellhead to be secure and free from signs of escaping gases, fluids, or signs of leakage. At the time of my inspection, fluid was being off-loaded from a tank truck into the pit. At the time of my inspection, the interior of the impoundment was dry. I observed the horizontal and vertical surface areas of the dike structures to be free from staining. Exterior su
1450883527 2015-12-21 Salt Water Injection Well No Violations I was on location in reference to complaint ID 5197. During my inspection, I found KDA has corrected to emergency contact information on the identification sign above the office. I called and left a message for a return call concerning the corrected identification sign with Mrs. Beiersdorfer. No further violations at this time.
1464115833 2019-10-28 0:00 SW No Violations 1.00
1469682633 2018-03-22 Salt Water Injection Well No Violations I was on location to inspect the injection well and facility. I found the well not operating on the day of my inspection. The wellhead is in good repair. The wooden fence around the well is locked. I observed no leaks or spills. The proper identification sign is posted. There are no violations at this time.
1517093427 2016-03-15 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1518410216 2014-05-16 Salt Water Injection Well No Violations The pump was not operating at the time. There were no violations found. However, the operator was informed of the two broken gauges found on the well.
1526563315 2018-05-17 Salt Water Injection Well Violations Noted I found the injection well not operating on the day of my inspection. I was unable to gauge the tubing and annulus due to the fittings could not be opened or closed. There is a locked fence surrounding the well. The proper identification is posted at the facility and well. I spoke to Jeremy Caldwell and the facility operator on location to replace the fitting. A compliance notice has been issued.

PAC has until 5/25/2018: Replace the fittings on the tubing and annulus.

A follow-up inspection will be conducted.

1528894337 2018-06-13 Salt Water Injection Well No Violations I was on location to assess compliance notice #1526563315. I found new fittings installed at the injection well. There was a facility operator on site. An identification sign is posted. I observed no leaks or spills. There are no violations at this time.
1532523889 2018-07-25 Salt Water Injection Well No Violations I found the impacted gravel from the leaking fitting removed and the fitting repaired per my request.
1541431155 2018-11-05 Salt Water Injection Well No Violations I found the injection well not operating on the day of my inspection. There were facility operators on location. The injection well is surrounded by a locked wooden fence. Identification signs are posted. I observed no spills or leaks. A specific gravity (SG) sample was taken and got a 1.1 reading. A Smith Transport brine truck arrived on location with the proper UIC number displayed (#25-448).
1549462524 2019-02-06 Salt Water Injection Well Violations Noted I found the injection well not operating during my inspection. The pressure on the injection tubing gauged at 1,080 psi, which is above the maximum allowable pressure. The fencing around the injection well was locked. Identification signs are posted. I observed no leaks or spills. I instructed the facility operator not to operate the injection well until the pressure has dropped below the maximum allowable pressure. A compliance notice has been issued. A follow up inspection will be conducted by 2/7/2019.
1549896688 2019-02-11 Salt Water Injection Well No Violations I was on location to assess Compliance Notice #1549462524. I found the injection well pressure below the maximum allowable pressure. There is an identification sign posted. I observed no leaks or spills. There was a Spirit Services brine truck off-loading with the proper UIC number displayed (#25-562).
1552571716 2019-03-14 Salt Water Injection Well No Violations I was on location to assess Compliance Notice #66647115. I found the pressure on the injection well has dropped to 1,080 psi; however, the well was still over the maximum allowable pressure. The injection well was not in operation. There is an identification sign posted. I spoke with the facility operator, who stated the injection well will remain shut down until the pressure drops below the maximum allowable pressure. A follow-up inspection will be conducted.
1552656164 2019-03-15 Salt Water Injection Well No Violations I was on location to assess Compliance Notice #66647115. I found the injection well not in operation during my inspection and below the maximum allowable pressure with a reading of 990 psi. There was a facility operator on location. According to the facility operator, PAC is considering performing maintenance on the well in the near future. I observed no leaks or spills.
1556717751 2019-5-1 0:00:0 SW No Violations 1.40
1572372752 2019-10-29 0:00 SW No Violations 1.30
1573654994 2019-11-13 0:00 SW No Violations 0.50
1574713072 2019-11-25 0:00 SW No Violations 1.50
1583335969 2020-3-4 0:00:0 SW No Violations 1.30
1584559744 2020-3-18 0:00: SW No Violations 6.10
1584702932 2020-3-20 0:00: SW No Violations 5.00
1584722346 2020-3-20 0:00: SW No Violations 6.00
1585070252 2020-3-23 0:00: SW No Violations 7.00
1585736412 2020-8-27 0:00: SW No Violations 1.50
1590048479 2013-12-17 Salt Water Injection Well No Violations There were no violations at the time of inspection.
1594144125 2020-5-19 0:00: SW No Violations 0.50
1597772408 2020-8-18 0:00: SW No Violations 1.30
1597850071 2020-8-19 0:00: SW No Violations 1.00
1598276867 2020-8-24 0:00: SW No Violations 0.40
1601143129 2013-04-18 Salt Water Injection Well No Violations A contractor (Timco) was drilling out the remedial cement plug with a power swivel. All conditions were acceptable.
1603238546 2013-09-16 Surface Facility Construction No Violations My inspection of the surface facility construction found no problems.
1607249832 2013-04-23 Salt Water Injection Well No Violations The well was treated, by Nabors Completion & Production Services Co., with 3000 gallons 20% 3M Iron acid.

All conditions were acceptable.

1633606046 2014-06-10 Salt Water Injection Well No Violations An inspection of the well and injection facility found no violations.
1670892671 2015-03-19 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1698982963 2017-10-30 Salt Water Injection Well No Violations I found the UIC facility in good repair on the day of my inspection. The proper identification signs are posted at the facility and well. There are locked wooden fence surrounding the well. I observed no leaks or spills. There are no violations at this time.
1725618463 2017-02-15 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The pump was operating at the time. There were no violations found.
1793764185 2017-05-04 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1804968116 2016-06-10 Salt Water Injection Well No Violations At the time of my inspection, I found PAC Development has posted new identification signs on the office building and well. There are no violations at this time.
1834360032 2013-10-31 Salt Water Injection Well No Violations A mechanical integrity test was performed on the flow line. A pressure of 1300 psi. was held on the flow line for fifteen minutes. The test passed.
184094544 2015-12-14 0:00 SW No Violations 1.00
1852366862 2017-06-29 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The injection well was not in operation on the day of my inspection. A locked wooden fence with an identification sign surrounds the well. There were no violations at the time.
1863170979 2019-11-6 0:00: SW No Violations 1.00
1870941006 2013-09-05 Salt Water Injection Well No Violations My inspection of the well and injection facility found no violations.
1926858426 2020-5-28 0:00: SW No Violations 1.00
1939924559 2020-7-8 0:00:0 SW No Violations 1.00
1941465683 2014-10-30 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1998212051 2014-05-14 Salt Water Injection Well No Violations There were no violations at the time of inspection.
2009650432 2020-3-5 0:00:0 SW No Violations
2013874041 2015-07-14 Salt Water Injection Well No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
2016054882 2020-7-30 0:00: SW No Violations
2029564475 2015-04-23 Salt Water Injection Well Violations Noted At the time of this inspection, the well was operating at 40 psi. over the maximum allowable injection pressure. Matt Kleese was instructed to shut down the pump and reduce the injection pressure.
2029611566 2013-04-13 Salt Water Injection Well No Violations Previously, the casing was pressure tested twice and failed both times. The top 3,006 feet of 4-1/2 inch casing were replaced with new casing on a rubber sealed patch.

Two additional tests were conducted. The first test used a pressure of 1280 psi. on the tubing/casing annulus. The first attempt failed with a 180 psi. loss in fifteen minutes. A leaking fitting was tightened. A second test used a pressure of 1540 psi. on the tubing/casing annulus. The second attempt failed with a 200 psi. loss in fifteen minutes.

2035829478 2020-6-9 0:00:0 SW No Violations 1.30
2102923595 2013-04-30 Salt Water Injection Well No Violations A mechanical integrity test was performed with a pressure of 1150 psi. on the tubing-casing annulus. There was a loss of 30 psi. observed during the 15 minute test period. The well passed with a 2.6% loss in pressure.
2108350838 2019-12-30 0:00 SW No Violations 0.50
2112900745 2018-02-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. FEES AND REPORTS RECEIVED 3/7/2018.
2141757103 2020-3-26 0:00: SW No Violations 2.50
2145436391 2013-04-09 Salt Water Injection Well No Violations The well was plugged back to the Newburg. The initial total depth was tagged at 4487 feet. A string of 2-7/8 inch tubing was ran to 4380 feet. 25 sacks of Class-A cement, with 5 lb. of Gilsonite per sack, were pumped across the Clinton perforations. The well was reverse circulated at 4117 feet. The cement operation and well site conditions were acceptable.
225278534 2013-7-1 0:00:0 SW No Violations
244384091 2014-7-25 0:00: SW No Violations
314238672 2017-9-20 0:00: SW No Violations 0.40
519826056 2018-1-12 0:00: SW No Violations 0.50
530076386 2016-5-17 0:00: SW No Violations 0.30
530723686 2013-4-10 0:00: SW No Violations
561581921 2019-11-5 0:00: SW No Violations 0.50
58946072 2019-6-10 0:00: SW No Violations 0.30
595023586 2015-2-13 0:00: SW No Violations
612037210 2014-3-18 0:00: SW No Violations
66647115 2019-3-13 0:00: SW No Violations
671207208 2020-3-5 0:00:0 SW No Violations 0.60
675379256 2020-8-26 0:00: SW No Violations 0.60
695457503 2015-12-21 0:00 SW No Violations 1.00
843563620 2015-1-12 0:00: SW No Violations
873863014 2013-9-3 0:00:0 SC No Violations
986623649 2014-11-20 0:00 BH No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0066647115 US-OH-127545 2019-05-21 9-3-07(D) Exceeding maximum allowable injection pressure
0244384091 US-OH-122485 2014-10-06 Exceeding maximum allowable injection pressure
0839349100 US-OH-129547 2019-04-08 Failure to report disposal fees
1239185605 US-OH-106375 2019-05-09 Failure to file salt water injection annual report
1244042300 US-OH-106516 2019-03-06 9-3-07(D) Exceeding maximum allowable injection pressure
1377618488 US-OH-111193 2013-08-27 Exceeding maximum allowable injection pressure
1526563315 US-OH-114604 2018-07-17 9-3-05(A)3 Violation of injection tubing/fitting requirements
1549462524 US-OH-115040 2019-02-13 9-3-07(D) Exceeding maximum allowable injection pressure
2029564475 US-OH-120635 2015-10-15 Exceeding maximum allowable injection pressure
2112900745 US-OH-121612 2018-03-27 NONE Failure to report disposal fees