Well ID: 34-155-21702
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Brookfield Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: JURKO P
License Status: Producing
License Date: 1980-12-30
Spud Date: 1981-06-13
Spud Drilling Contractor:
Final Drill Date: 1981-06-16
Well Total Depth: 4917.00 ft
Configuration: Vertical
Latitude: 41.260000
Longitude: -80.560000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-12-30 54 TITAN ENERGY CORP GeoDate 12/30/80
Oil and Gas 1980-12-30 Issued Date 12/30/80 Expired Date Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1981-06-13
Completed 1981-06-16
Reached Total Depth 1981-06-16
Completion Report Received 1981-06-22
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Change of Owner 2017-04-13 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-04-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4702 4774 19
4702 4774 19
4702 4774 19

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 80000 Gal 67000
N2 0 228 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TITAN ENERGY CORP 8492.00 124.00 0
1985 TITAN ENERGY CORP 6029.00 0.00 365
1986 TITAN ENERGY CORP 4012.00 61.00 365
1987 TITAN ENERGY CORP 2907.00 74.00 365
1988 TITAN ENERGY CORP 3252.00 0.00 365
1989 TITAN ENERGY CORP 3449.00 75.00 365
1990 TITAN ENERGY CORP 3038.00 61.00 365
1991 TITAN ENERGY CORP 1941.00 0.00 365
1992 TITAN ENERGY CORP 2654.00 0.00 365
1993 TITAN ENERGY CORP 2578.00 62.00 365
1994 TITAN ENERGY CORP 1000.00 0.00 365
1997 TITAN ENERGY CORP 2743.00 27.00 245
2000 BIG SKY ENERGY INC 2062.00 66.00 365
2001 BIG SKY ENERGY INC 2976.00 18.00 365
2002 BIG SKY ENERGY INC 2057.00 22.00 365
2003 BIG SKY ENERGY INC 1980.00 0.00 365
2004 BIG SKY ENERGY INC 1890.00 101.00 365
2005 BIG SKY ENERGY INC 2125.00 0.00 365
2006 BIG SKY ENERGY INC 2300.00 0.00 365
2008 BIG SKY ENERGY INC 3128.00 0.00 365
2009 BIG SKY ENERGY INC 3754.00 0.00 365
2010 BIG SKY ENERGY INC 3322.00 0.00 365
2011 BIG SKY ENERGY INC 2296.00 0.00 365
2012 BIG SKY ENERGY INC 1445.00 0.00 366
2013 BIG SKY ENERGY INC 1825.00 49.00 365
2014 BIG SKY ENERGY INC 1721.00 16.00 365
2016 BIG SKY ENERGY INC 2209.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TITAN ENERGY CORP Brine 0 0
1985 TITAN ENERGY CORP Brine 0 365
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 TITAN ENERGY CORP Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 0 365
1997 TITAN ENERGY CORP Brine 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1322163831 2016-4-19 0:00: UP No Violations
-370941887 2015-8-11 0:00: UP No Violations 0.50
-698402451 2019-9-4 0:00:0 UP No Violations
-8571807 2017-12-6 0:00: UP No Violations
0008571807 2017-12-06 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 124830954. At the time of this inspection, the annulus and flow line valves on the well were open. Identification has been posted at the well. The tank battery consisted of two 100 BBL production tanks, two 50 BBL steel brine tanks. Two heater treater separators were also present and had been installed outside of the diked tank battery. Valves on the separator were open and the chart dated 11/9/17 showed production. The oil impacted soil within the diked battery has not been removed and both heater tubes on the 100 BBL production tanks were actively leaking. Identification signs have been stenciled onto the right door of the separator with the current owner information. The access road was stable. The tank battery was shared with permits #2-2236 and #2-2235.
0370941887 2015-08-11 UrbanProduction Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The tank battery consists of a 100 barrel production tank, a 50 barrel brine tank, and two (2), mechanical separators. A dike surrounds the tanks. An identification sign is posted on the separator. A plug is installed on the load line. The lease road is paved and in good condition. The well shares the tank battery with permit numbers 2-2235 and 2-2236. The well was placed into production prior to House Bill 278.
0556682078 2017-03-10 UrbanProduction Wells No Violations I was on location to assess compliance notice #--2236 and #2-2235.

Big Sky still needs to: 1) Clean-up and remove all of the oil in the tank battery and properly dispose of the impacted soil. 2) Add signage to the wellhead. 3) The well needs shut in immediately per the temporary restraining order issued by the Trumbull County Court of Common Pleas, dated 4/11/2016. 4) Properly remove the standing water from the tank battery.

0705864353 2016-09-15 UrbanProduction Wells No Violations I was on location to assess compliance notice # --2235 and 2-2236. Photos were taken and are available upon request.
0966660513 2018-01-29 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1322163831. At the time of this inspection, the annulus and flow line valves on the well were open. Identification has been posted at the well. The tank battery consisted of two 100 BBL production tanks, two 50 BBL steel brine tanks. Two heater treater separators were also present and had been installed outside of the diked tank battery. Valves on the separator were open and the chart dated 1/4/18 showed production. The oil impacted soil within the diked battery could not be seen due to the standing frozen water within the battery. One of the heater tubes on the 100 BBL production tank was still actively leaking. Identification signs have been stenciled onto the right door of the separator with the current owner information. The access road was stable. The tank battery was shared with permits #2-2236 and #2-2235.
1322163831 2016-04-19 UrbanProduction Wells Violations Noted I conducted an inspection on this well. The well is equipped with a plunger lift assembly and the valve on the wellhead was open. The tank battery consists of two, 100 BBL production tanks, two, 50 BBL brine tanks, and two mechanical separators. The last date on the chart was 2/29/16 and showed production. There is pooled oil within the tank battery covering half of the inside of the tank battery. Absorbant pads have been placed on top of the pooled oil. A dike surrounds the tanks. The well shares the tank battery with permits 22236 and 22235. Identification signs are posted on the separators but not the wellhead. The lease road is stable and driveable. The following items need addressed:

1) Clean-up and remove all of the oil in the tank battery and properly dispose of the impacted soil. 2) Add signage to the wellhead. 3) The well needs shut in immediately per the temporary restraining order issued by the Trumbull County Court of Common Pleas, dated 4/11/2016.

1549389416 2019-02-05 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1322163831, regarding the repair of the leaking production tanks and cleanup of impacted material within the tank battery. At the time of this inspection, the well was equipped with a plunger lift assembly and in production. The tank battery consisted of two 100 BBL production tanks, two 50 BBL steel brine tanks. Two heater treater separators were also present and had been installed outside of the diked tank battery. Valves on the separator were open and the chart on the sales line showed production. The oil impacted soil within the diked battery could not be seen due to the standing frozen water within the battery. The heater tube on the 100 BBL production tank was not visible due to frozen ice around the tank, and I could not see if the heater tube was still leaking. Identification signs have been stenciled onto the right door of the separator with the current owner information and have been installed at the well location. The access road was stable. The tank battery was shared with permits #2-2236 and #2-2235.
556682078 2017-3-10 0:00: UP No Violations 0.50
705864353 2016-9-15 0:00: UP No Violations 0.70
966660513 2018-1-29 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1322163831 US-OH-109216 2016-05-26 ID (a-i)
1322163831 US-OH-109217 2016-05-26 Well operation causing pollution and contamination
1322163831 US-OH-109218 2016-05-26 Failure to keep dike or pit free of brine or other wastes

For data sources see[9]