34-155-20854

Well Details

Well ID: 34-155-20854
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bristol Township
Operator Name: VANGUARD OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: BOORN UNIT
License Status: Plugged and Abandoned
License Date: 2013-03-08
Spud Date: 1978-04-02
Spud Drilling Contractor:
Final Drill Date: 1978-04-08
Well Total Depth: 4134.00 ft
Configuration: Vertical
Latitude: 41.400000
Longitude: -80.880000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1978-04-02
Completed 1978-04-08
Reached Total Depth 1978-04-08
CO 1981-06-30 271 TGX CORP GeoDate 6/30/81
CO 1994-03-29 182 BELDEN & BLAKE CO GeoDate 6/30/81
CO 1995-10-11 1966 PETROX INC GeoDate 6/30/81
CO 1995-10-27 1966 PETROX INC GeoDate 10/27/95
Unknown 1995-10-27 Issued Date 10/27/95 Expired Date 10/26/96 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Unknown 1997-03-10 Issued Date 3/10/97 Expired Date 3/10/98 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Change of Owner 2004-08-11 Operator changed from 1966, PETROX, INC to 6970, VANGUARD OIL & GAS LLC
APP 2013-03-08 Proposed Formations:CLINTON, Issued Date:3/8/2013, Expired Date:3/8/2015 12:00:00 PM, Drilling unit acres:99, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2013-06-24
Construction Permit Expires 2015-03-08
Record Last Modified 2017-02-10

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3887 3991 1
3887 3991 1
3887 3991 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 800 Bbl 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TGX CORP 3328.00 108.00 0
1985 TGX CORP 664.00 49.00 365
1986 TGX CORP 178.00 52.00 130
1987 TGX CORP 151.00 50.00 135
1988 TGX CORP 121.00 46.00 135
1989 TGX CORP 95.00 34.00 365
1990 TGX CORP 110.00 69.00 365
1991 TGX CORP 74.00 28.00 150
1992 TGX CORP 0.00 0.00 365
1993 TGX CORP 0.00 0.00 0
2005 VANGUARD OIL & GAS LLC 0.00 0.00 0
2006 VANGUARD OIL & GAS LLC 0.00 0.00 0
2007 VANGUARD OIL & GAS LLC 0.00 0.00 0
2008 VANGUARD OIL & GAS LLC 440.00 123.00 365
2009 VANGUARD OIL & GAS LLC 320.00 79.00 365
2010 VANGUARD OIL & GAS LLC 586.00 80.00 365
2011 VANGUARD OIL & GAS LLC 2120.00 57.00 0
2012 VANGUARD OIL & GAS LLC 0.00 0.00 366
2013 VANGUARD OIL & GAS LLC 907.00 74.00 365
2015 VANGUARD OIL & GAS LLC 150.00 0.00 365
2016 VANGUARD OIL & GAS LLC 424.00 58.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TGX CORP Brine 160 0
1985 TGX CORP Brine 181 365
1986 TGX CORP Brine 107 130
1987 TGX CORP Brine 0 135
1988 TGX CORP Brine 0 135
1989 TGX CORP Brine 0 365
1990 TGX CORP Brine 30 365
1991 TGX CORP Brine 0 150
1992 TGX CORP Brine 0 365
1993 TGX CORP Brine 0 0
2005 VANGUARD OIL & GAS LLC Brine 0 0
2006 VANGUARD OIL & GAS LLC Brine 0 0
2007 VANGUARD OIL & GAS LLC Brine 0 0
2008 VANGUARD OIL & GAS LLC Brine 360 365
2009 VANGUARD OIL & GAS LLC Brine 277 365
2010 VANGUARD OIL & GAS LLC Brine 260 365
2011 VANGUARD OIL & GAS LLC Brine 197
2012 VANGUARD OIL & GAS LLC Brine 0 366
2013 VANGUARD OIL & GAS LLC Brine 160 365
2015 VANGUARD OIL & GAS LLC Brine 154 365
2016 VANGUARD OIL & GAS LLC Brine 120 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-112008005 2013-6-24 0:00: PB No Violations 4.00
-1855348683 2015-3-2 0:00:0 PB No Violations 1.00
-237031596 2015-3-5 0:00:0 FR No Violations
-618646519 2013-6-18 0:00: PB No Violations 2.50
-734337644 2013-6-25 0:00: PB No Violations 1.00
-769172609 2015-3-4 0:00:0 FR No Violations
-931015867 2011-7-15 0:00: PW No Violations
0112008005 2013-06-24 Plug / Plug Back No Violations I witnessed Petroset set the final two plugs. The rig operator ran tubing to 2,191 to set the Big Lime plug. Petroset established circulation and pumped 75 sacks of Class A cement. The operator displaced the cement with 6 bbls of fresh water. Then the rig operator removed 61 joints to set the surface plug. Petroset established circulation with 6 bbls of fresh water and pumped 130 sacks of Class A cement. I witnessed good cement returned to surface. The rig operator removed the final 14 joints and the cement was topped off at the surface. The cement was static at surface after 20 minutes. A total of 62 joints of 4.5 casing was removed from the well.
0237031596 2015-03-05 Final Restoration No Violations My inspection found the cement was at the surface and the plug had held. No signs of gas coming from the well. I will contact the company to have the casing cut off and the plate installed. No violations found.
0548792238 2011-11-10 Production Wells No Violations No action has been taken to plug or produce the well.
0618646519 2013-06-18 Plug / Plug Back No Violations I witnessed Appalachian Well Surveys bond log the well for Vanguard. The operator tagged the top of the bottom plug at 3,755. The Salina Salt was estimated at 2,830. Appalachian ripped the 4.5 casing at 2,533. The final plugs are scheduled to be completed by 6/24/2013.
0734337644 2013-06-25 Plug / Plug Back No Violations My inspection found the cement static at surface. Vanguard plans to complete the plug job today and begin final restoration of the site; no violations at this time.
0769172609 2015-03-04 Final Restoration No Violations I was on location for Inpsector Skidmore to witness the plugging of this oil and gas well. The well was not showing any signs of gas. Nicks Well Plugging is the contractor on location to plug the well. Nicks tripped 1.5 tubing into the well and tagged the Big Lime Plug at 2190. The well was circulated on for 30 minutes to clear the wellbore of any debris. Nicks pumped 58 sacks (200) of Class A cement on top of the previous Big Lime Plug. Nicks pulled the 1.5 tubing up to 433, broke circulation, and pumped 60 sacks of Class A cement to cover the bottom of the surface casing. Nicks pulled the 1.5 casing up to 200, broke circulation, and pumped 62 sacks of Class A cement. Cement was circulated to the surface. The tubing was removed from the well and the well was topped off with cement. The well is not to be cut off and plate installed until after my inspection on 3/5/2015.
0931015867 2011-07-15 Production Wells No Violations FOLLOW UP TO NOV # 1997318012 An inspection found the well incapable of production and without identification. The rods and tubing were removed. A swage and valve were the only equipment remaining on the production casing.

Post complete identification at the well.

Plug or produce the well or apply for temporary inactive status.

1339705485 2012-05-02 Production Wells No Violations My follow-up inspection of this well site found no action has been taken to plug or produce the well.
1372082472 2013-06-12 Plug / Plug Back No Violations I witnessed Petroset set the bottom plug for Vanguard. The top and bottom perforation was at 3,887 and 3,991. Summit Well Service dug and lined the brine pit. The service rig operator ran 1.5 tubing to 3,957. Petroset established circulation with 35 bbls of fresh water and pumped 30 sacks of Class A cement. The operator displaced with approximately 10 bbls of fresh water. Appalachian Well Surveys was scheduled for 6/18/2013 to tag the bottom plug and rip the 4.5 casing.
1810676408 2012-09-20 Production Wells Violations Noted I conducted a production well inspection status check. My inspection found the well equipped with a pumping unit that was overgrown with weeds, grass, and small trees. The tank battery contained one, 210 barrel oil storage tank, one, 50 barrel brine storage tank, a separator, and the proper identification. I noticed no visible spills or leaks. This well shares a tank battery with permit numbers 2-0853. I researched our database and found no production since 2002. I called the Vanguard Office at 330-223-1074 and told them to produce, file for a plugging permit, or file for tempory inactive status. I will perform a follow-up inspection by 10/31/2012.
1855348683 2015-03-02 Plug / Plug Back No Violations I was on location to witness Appalachian Well Service drill out the top plug for Nicks Well Plugging. During my inspection, I found the rig was not on location. I spoke with Nick, who stated the rig was enroute. The well site was cleared of snow. A pit was dug and properly lined.
1997318012 2011-07-15 Production Wells Violations Noted An inspection found the well incapable of production and without identification. The rods and tubing were removed. A swage and valve were the only equipment remaining on the production casing.

Post complete identification at the well.

Plug or produce the well or apply for temporary inactive status.

548792238 2011-11-10 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1810676408 US-OH-118084 2012-11-23 Nonproduction; well shall be plugged or placed in temporary inactive status
1997318012 US-OH-120269 2011-07-24 Failure to legibly identify well
1997318012 US-OH-120270 2011-07-27 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[9]

References