34-153-23141

Well Details

Well ID: 34-153-23141
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: INDUSTRY STANDARD SUPPLIES INC
Well Pad ID:
Farm/Lease Name: R.J. SEABECK UNIT
License Status: Producing
License Date: 2011-08-09
Spud Date: 2011-08-20
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2011-08-25
Well Total Depth: 3910.00 ft
Configuration: Vertical
Latitude: 41.040000
Longitude: -81.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-08-09 Proposed Formations:CLINTON, Issued Date:8/9/2011, Expired Date:8/8/2013 12:00:00 PM, Drilling unit acres:23.2215, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-08-25
Completion Report Received 2012-02-24
Construction Permit Expires 2012-08-08
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-03-06 3762 3782 41
3762 3782 41
3762 3782 41

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-09-16 H2O 0 58841 Gal 30000 Superior Well Services

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 INDUSTRY STANDARD SUPPLIES INC 0.00 0.00 365
2012 INDUSTRY STANDARD SUPPLIES INC 10012.00 1240.00 306
2013 INDUSTRY STANDARD SUPPLIES INC 10090.00 978.00 365
2014 INDUSTRY STANDARD SUPPLIES INC 7270.00 711.00 365
2015 INDUSTRY STANDARD SUPPLIES INC 5386.00 592.00 365
2016 INDUSTRY STANDARD SUPPLIES INC 6311.00 565.00 365
2017 INDUSTRY STANDARD SUPPLIES INC 3601.00 353.00 365
2018 INDUSTRY STANDARD SUPPLIES INC 2026.00 334.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2012 INDUSTRY STANDARD SUPPLIES INC Brine 0 306
2013 INDUSTRY STANDARD SUPPLIES INC Brine 77 365
2014 INDUSTRY STANDARD SUPPLIES INC Brine 63 365
2015 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2016 INDUSTRY STANDARD SUPPLIES INC Brine 67 365
2017 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2018 INDUSTRY STANDARD SUPPLIES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-149447472 2011-11-4 0:00: UD No Violations
-1982534959 2011-9-8 0:00:0 UD No Violations
-284346797 2009-8-23 0:00: UD No Violations
-843771531 2011-9-6 0:00:0 UD No Violations
0149447472 2011-11-04 Urban Drill / Deepen / Reopen No Violations The well has been fraced and is equipped with tubing, rods and a pump jack. The tank battery equipment is on site but has not been connected. No violations at this time.
0163742938 2011-08-22 Urban Drill / Deepen / Reopen No Violations Poulson Drilling is drilling at 2050 on air/soap. They will covert to fluid at the top of the Big Lime later today. The pits are fenced, lined and in good condition.
0284346797 2009-08-23 Urban Drill / Deepen / Reopen No Violations Poulson Drilling is drilling at 2900 on salt water. They coverted to fluid at the top of the Big Lime. The pits are fenced, lined and in good condition.
0301232845 2011-08-29 Urban Drill / Deepen / Reopen No Violations The drilling rig has moved off site. The drilling pits have been pumped down and are still fenced and lined. Pit solidification is still scheduled for next week.
0434183832 2011-08-24 Urban Drill / Deepen / Reopen No Violations Poulson Drilling is drilling at 3570 on salt water. They should TD the well tomorrow. The pits are fenced, lined and in good condition.
0781903660 2011-08-25 Urban Drill / Deepen / Reopen No Violations Poulson has finished drilling the well with a TD at 3910. The longstring job will be up later today. The drilling pits are fenced, lined and in good condition. The Uniontown office received a water well complaint from Gregory Tygard (330-289-2605) at 3559 Wadsworth Road. Mr. Tygard lives two doors east of Mr. Seabeck. His complaint involves water quality after he noticed an increase in suspended sediment in his water supply. Mr. Tygard denied permission when ISSI was collecting pre-drilling water samples. The complaint information was forwarded to Kyle Tharp for an investigation.
0843771531 2011-09-06 Urban Drill / Deepen / Reopen No Violations Chem Tech was on site to solidify the drilling pits with one load (20+ tons) of dust for each pit. Mr. Seabeck provided the trackhoe to mix the dust and cover over the pit. Pit closure occurred within the required 14 days. Preliminary Restoration is due by the first of December.
1002809183 2016-06-01 UrbanProduction Wells No Violations I was on the Seabeck Unit # 1 to witness the repairs to the saddle bearings in order to satisfy a noise complaint in Compliant # 5333. The walk beam was removed from the Sampson post and new bearings were installed. After re-installation of the walking beam the pumping unit was greased and restarted without the offending noise. The Complaint also mentioned the lack of landscaping surrounding the pumping unit. The well is positioned in a gravelled parking lot which would not support landscaping. The Operator, previously, had planted white pines in the line of sight from the Complainants residence which offer some screening. No violations idenified during this inspection.
1314879190 2011-08-26 Urban Drill / Deepen / Reopen No Violations Poulson Drilling is moving off location. The drilling pits are fenced, lined and in good condition. The pits will be solidified and closed within 14 days.
1464111257 2016-05-23 UrbanProduction Wells No Violations I inspected the Seabeck Unit # 1 in response to a noise complaint ( # 5333 ) initiated by a neighbor. The well was completed in August, 2011. The well was constructed with 74 of 11.75 conductor casing, 347 of 8.625 surface casing, 3909 of 4.5 production casing and 3753 of 2.375 tubing. The Owner was current in the reporting of production volumes of oil, natural gas and brine. The well was operated by an electric pumping unit and was fenced and locked. The stuffing box had leaked previously and covered the wellhead with oil and paraffin. The tank battery was comprised of a 210 barrel oil tank, a 100 barrel brine tank and 2408 horizontal separator with meter. The tank battery was secured with a locked fence and surrounded with an earthen dike. The petcock at the brine drain had accumulated oil and paraffin on the fittings and ground. The tanks had the required pressure relief hatch, charcoal filter and lightening suppressor. Aside from the previously noted leaks the equipment was free from leaks. I spoke with Tim Levengood (330.204.0313 ) concerning the noise issue and clean up around the wellhead and brine drain. Mr. Levengood said, the saddle bearings on the sampson post were bad and required replacement. They were on order from Miller Supply and would be installed as soon as he received them. The clean up would done within a day. I will re-inspect once the repairs have been made.
163742938 2011-8-22 0:00: UD No Violations
1982534959 2011-09-08 Urban Drill / Deepen / Reopen No Violations The drilling pits were solidified on 9/6/11 and have now been covered over. Perforating is scheduled for 9/9/11 and the frac job for next week.
301232845 2011-8-29 0:00: UD No Violations
434183832 2011-8-24 0:00: UD No Violations
781903660 2011-8-25 0:00: UD No Violations

For data sources see[9]