X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-153-22924

Well Details

Well ID: 34-153-22924
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Bath Township
Operator Name: TRANSCONTINENTAL OIL & GAS INC
Well Pad ID:
Farm/Lease Name: O'NEILL
License Status: Producing
License Date: 2002-05-09
Spud Date: 2002-10-28
Spud Drilling Contractor: LANDOGS DRILLING
Final Drill Date: 2002-11-04
Well Total Depth: 3831.00 ft
Configuration: Directional
Latitude: 41.160000
Longitude: -81.620000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2002-05-09 Proposed Formations:CLINTON, Issued Date:5/9/2002, Expired Date:5/9/2003 6:00:00 AM, Drilling unit acres:23.95, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2002-06-21 CHANGE IN SURFACE FOOTAGE TO 577'NL & 570'EL OF LOT 55
Original Spud 2002-10-28 RBDMS Rec
Completed 2002-11-04 RBDMS Rec
Reached Total Depth 2002-11-04 RBDMS Rec
Completion Report Received 2003-03-27 RBDMS Rec
Correction to Well 2003-04-04 CHANGE IN TARGET LOCATION: 485'NL & 1073'EL OF LOT 55; X= 2,239268, AND Y= 548,019. UNIT SIZE INCREASED TO 66.023 ACRES.
Construction Permit Expires 2003-05-09 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-05-15 3553 3592 28
3553 3592 28
3553 3592 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 109174 Gal 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 TRANSCONTINENTAL OIL & GAS INC 9907.00 1859.00 365
2004 TRANSCONTINENTAL OIL & GAS INC 12911.00 986.00 365
2005 TRANSCONTINENTAL OIL & GAS INC 6808.00 648.00 365
2006 TRANSCONTINENTAL OIL & GAS INC 5195.00 393.00 365
2007 TRANSCONTINENTAL OIL & GAS INC 3748.00 364.00 364
2008 TRANSCONTINENTAL OIL & GAS INC 3369.00 224.00 365
2009 TRANSCONTINENTAL OIL & GAS INC 2787.00 202.00 365
2010 TRANSCONTINENTAL OIL & GAS INC 5154.00 440.00 365
2011 TRANSCONTINENTAL OIL & GAS INC 6577.00 387.00 365
2012 TRANSCONTINENTAL OIL & GAS INC 5343.00 347.00 366
2013 TRANSCONTINENTAL OIL & GAS INC 3320.00 218.00 365
2014 TRANSCONTINENTAL OIL & GAS INC 2980.00 169.00 365
2015 TRANSCONTINENTAL OIL & GAS INC 4086.00 167.00 365
2016 TRANSCONTINENTAL OIL & GAS INC 3219.00 182.00 365
2017 TRANSCONTINENTAL OIL & GAS INC 2554.00 218.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 TRANSCONTINENTAL OIL & GAS INC Brine 808 365
2004 TRANSCONTINENTAL OIL & GAS INC Brine 45 365
2005 TRANSCONTINENTAL OIL & GAS INC Brine 32 365
2006 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2007 TRANSCONTINENTAL OIL & GAS INC Brine 25 364
2008 TRANSCONTINENTAL OIL & GAS INC Brine 32 365
2009 TRANSCONTINENTAL OIL & GAS INC Brine 70 365
2010 TRANSCONTINENTAL OIL & GAS INC Brine 105 365
2011 TRANSCONTINENTAL OIL & GAS INC Brine 100 365
2012 TRANSCONTINENTAL OIL & GAS INC Brine 70 366
2013 TRANSCONTINENTAL OIL & GAS INC Brine 35 365
2014 TRANSCONTINENTAL OIL & GAS INC Brine 105 365
2015 TRANSCONTINENTAL OIL & GAS INC Brine 105 365
2016 TRANSCONTINENTAL OIL & GAS INC Brine 107 365
2017 TRANSCONTINENTAL OIL & GAS INC Brine 70 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1702371642 2003-1-8 0:00:0 PW No Violations
-1979277888 2004-2-18 0:00: PW No Violations
1037154788 2002-11-04 Drill / Deepen / Reopen No Violations Status check inspection after the drilling was completed. Landogs Rig #1 completed the 1-D well and was being moved 100 feet north to spud the 2-D well. No violations at the 1-D site. The suction pit fluids will be transferred to the 2-D pits once they are lined.
1079038172 2004-03-10 Production Wells Violations Noted The two 210 bbl stock tanks have been labeled, one brine and the other stock with the stock tank being over 10 feet from the nearest separator. The violation is corrected.
1702371642 2003-01-08 Production Wells No Violations November 18, 2002 - The subject site was inspected for the purpose of determining the distance between the tank battery under construction and a vacant house south of the tank battery. The inspection was prompted by a spacing question posed to me by the Bath Township Zoning office. A roustabout crew was on site at the time of this inspection and assisted in measuring the distance between the house and the nearest stock tank. The measured distance was 83 feet and the crew was informed of the minimum distance requirements, including 100 feet between an occupied dwelling and a stock tank. Mr. Cal Marks with Transcontinental was notified of the problem by phone. Several possible locations were discussed and I reminded him of the minimum spacing requirements before leaving the site. A NOV was not issued since the tank battery was not operational.

December 3, 2002 - I was informed that the tank battery was relocated south of house and that it met all spacing requirements. January 8, 2003 - The site was inspected and I was told by the same roustabout crew that the tanks were 108 feet from the house and 70 feet from the wellhead. The site has been rough graded and the pits have been solidified. The secondary containment dike has been constructed around the tank battery. The well will be turned on in the very near future. No violations at this time.

1740218041 2002-11-18 Drill / Deepen / Reopen No Violations The drilling rig has moved off and the pits are being pumped out and solidified.
1979277888 2004-02-18 Production Wells Violations Noted A status check inspection found that the tank battery equipment did not have the required distance between the separators and the tanks. The required distance between separator and tank is ten feet, the actual is less than three feet. Common tank battery with the ONeill 2-D P/N 2925.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1079038172 US-OH-101720 2004-02-25 Violation of separator spacing requirements
1979277888 US-OH-120018 2004-02-25 Violation of separator spacing requirements

For data sources see[9]