34-153-21564

Well Details

Well ID: 34-153-21564
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: RUBBER CITY OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: GENERAL TIRE
License Status: Producing
License Date: 1983-11-01
Spud Date: 1983-12-01
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1983-12-07
Well Total Depth: 4060.00 ft
Configuration: Vertical
Latitude: 41.050000
Longitude: -81.460000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1983-11-01 Issued Date 11/1/83 Expired Date 4/29/84 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04060 Proposed Drill Depth 04060
Original Spud 1983-12-01
Completed 1983-12-07
Reached Total Depth 1983-12-07
CO 1984-02-08 518 GOODYEAR TIRE & RUBBER GeoDate 11/1/83
Completion Report Received 1984-02-13
Construction Permit Expires 1984-04-29
Change of Owner 2009-07-22 Operator changed from 518, GOODYEAR TIRE & RUBBER to 8530, GENERAL STREET BUSINESS PARK
Change of Owner 2010-02-10 Operator changed from 8530, GENERAL STREET BUSINESS PARK to 8608, RUBBER CITY OIL & GAS LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3854 3853 0
3854 3853 0
2006-09-11 3882 3948 25
3882 3948 25
3854 3853 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 91000 Gal 50000 FRAC;H2O,SAND,N2
N2 0 90 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GOODYEAR TIRE & RUBBER 68842.00 1124.00 365
1985 GOODYEAR TIRE & RUBBER 61659.00 625.00 0
1986 GOODYEAR TIRE & RUBBER 73560.00 425.00 365
1987 GOODYEAR TIRE & RUBBER 32386.00 264.00 365
1988 GOODYEAR TIRE & RUBBER 56392.00 339.00 365
1989 GOODYEAR TIRE & RUBBER 90301.00 224.00 365
1990 GOODYEAR TIRE & RUBBER 80572.00 173.00 365
1991 GOODYEAR TIRE & RUBBER 57407.00 80.00 365
1992 GOODYEAR TIRE & RUBBER 35622.00 240.00 365
1993 GOODYEAR TIRE & RUBBER 12200.00 0.00 365
1994 GOODYEAR TIRE & RUBBER 41426.00 401.00 365
1995 GOODYEAR TIRE & RUBBER 16898.00 126.00 365
1996 GOODYEAR TIRE & RUBBER 5552.00 0.00 365
1997 GOODYEAR TIRE & RUBBER 2824.00 153.00 0
1998 GOODYEAR TIRE & RUBBER 1697.00 85.00 365
1999 GOODYEAR TIRE & RUBBER 1707.00 120.00 365
2000 GOODYEAR TIRE & RUBBER 2462.00 0.00 365
2001 GOODYEAR TIRE & RUBBER 3990.00 127.00 365
2002 GOODYEAR TIRE & RUBBER 1882.00 0.00 365
2003 GOODYEAR TIRE & RUBBER 1331.00 0.00 365
2004 GOODYEAR TIRE & RUBBER 903.00 0.00 365
2005 GOODYEAR TIRE & RUBBER 969.00 0.00 365
2006 GOODYEAR TIRE & RUBBER 1308.00 0.00 365
2007 GOODYEAR TIRE & RUBBER 0.00 0.00 365
2008 GOODYEAR TIRE & RUBBER 0.00 56.00 0
2009 GENERAL STREET BUSINESS PARK 0.00 0.00 0
2010 RUBBER CITY OIL & GAS LLC 2508.00 639.00 308
2011 RUBBER CITY OIL & GAS LLC 4135.00 379.00 365
2012 RUBBER CITY OIL & GAS LLC 3981.00 257.00 366
2013 RUBBER CITY OIL & GAS LLC 3286.00 208.00 365
2014 RUBBER CITY OIL & GAS LLC 2843.00 225.00 365
2015 RUBBER CITY OIL & GAS LLC 2598.00 107.00 365
2016 RUBBER CITY OIL & GAS LLC 2271.00 69.00 365
2017 RUBBER CITY OIL & GAS LLC 1935.00 64.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GOODYEAR TIRE & RUBBER Brine 1065 365
1985 GOODYEAR TIRE & RUBBER Brine 0 0
1986 GOODYEAR TIRE & RUBBER Brine 0 365
1987 GOODYEAR TIRE & RUBBER Brine 0 365
1988 GOODYEAR TIRE & RUBBER Brine 0 365
1989 GOODYEAR TIRE & RUBBER Brine 0 365
1990 GOODYEAR TIRE & RUBBER Brine 0 365
1991 GOODYEAR TIRE & RUBBER Brine 0 365
1992 GOODYEAR TIRE & RUBBER Brine 0 365
1993 GOODYEAR TIRE & RUBBER Brine 0 365
1994 GOODYEAR TIRE & RUBBER Brine 0 365
1995 GOODYEAR TIRE & RUBBER Brine 166 365
1996 GOODYEAR TIRE & RUBBER Brine 25 365
1997 GOODYEAR TIRE & RUBBER Brine 0
1998 GOODYEAR TIRE & RUBBER Brine 0 365
1999 GOODYEAR TIRE & RUBBER Brine 0 365
2000 GOODYEAR TIRE & RUBBER Brine 0 365
2001 GOODYEAR TIRE & RUBBER Brine 0 365
2002 GOODYEAR TIRE & RUBBER Brine 0 365
2003 GOODYEAR TIRE & RUBBER Brine 0 365
2004 GOODYEAR TIRE & RUBBER Brine 0 365
2005 GOODYEAR TIRE & RUBBER Brine 0 365
2006 GOODYEAR TIRE & RUBBER Brine 0 365
2007 GOODYEAR TIRE & RUBBER Brine 0 365
2008 GOODYEAR TIRE & RUBBER Brine 25 0
2009 GENERAL STREET BUSINESS PARK Brine 0 0
2010 RUBBER CITY OIL & GAS LLC Brine 70 308
2011 RUBBER CITY OIL & GAS LLC Brine 560 365
2012 RUBBER CITY OIL & GAS LLC Brine 315 366
2013 RUBBER CITY OIL & GAS LLC Brine 280 365
2014 RUBBER CITY OIL & GAS LLC Brine 175 365
2015 RUBBER CITY OIL & GAS LLC Brine 105 365
2016 RUBBER CITY OIL & GAS LLC Brine 0 365
2017 RUBBER CITY OIL & GAS LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1892470323 2009-4-1 0:00:0 PW No Violations
0000PL4590 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0683581326 2016-12-05 UrbanProduction Wells No Violations I inspected the tank battery for the General Tire # 1 & # 2 for compliance with OAC 1501-9-9-05 ( E ) after the relocation of the tank battery due to road construction. The tank battery was utilized by the General Tire # 1 and General Tire # 2 ( 34-153-2-1565 ). The relocated tank battery consisted of two (2) 100 barrel tanks, two (2) 2408 horizontal separators, two (2) orifice gas meters and one (1) positive shut off drip tank.. No leaks or contamination were idenified during this inspection. The load lines were plugged and locked. The tank battery was surrounded with an earthen dike and an eight (8) foot chain link fence topped with three (3) strands of barbed wire. There were two (2) locked man doors incorporated into the fence. The tank battery was identified with signage that reflected the Urban requirements and had posted the required Danger : No Trespass, No Smoking signage on the tanks. The spacing requirements between the equipment and any non - participating Landowner was observed. The tanks were equipped with sealing inspection hatches ( fastened shut ), lightning arrestor, charcoal filter and pressure relief valves on the vents. The area of disturbance was graded, seeded and strawed with silt fencing installed toward the Little Cuyahoga River. The City of Akron placed screening landscaping around the tank battery. The contactor removed the gravel pad of the old tank battery and grade the area. This area of disturbance was not seeded due imminent road construction. I did not identify any violations during this inspection.
1449074044 2015-12-02 UrbanProduction Wells No Violations I inspected the General Tire # 1 well and tank battery on 12/2/2015. The well is operated as an electrified pumping well. The well head piping and fittings were configured as a pumping well head. The pump jack is surrounded by a locked fenced enclosure. Signage is in place, but list both wells information, which is confusing. I requested that this sign be replaced with one that lists the proper information for the # 1 well only. The tank battery consists of two (2) 100 barrel stock tanks, two (2) 2408 mechanical separators and a gas measurement station. The facility is surrounded by chain link fencing with three (3) strands of barbed wire atop. The gates were locked and secure. The equipment was free from leaks and contamination. The load lines, while plugged, did not have locks in place, the inspection hatches were not tightened down and there was two (2) inch black plastic piping laying outside the tank battery. I spoke with Mike Schrock ( well tender ) to have these deficiencies remedied. This tank battery will be relocated, due to development in the area. I told Mr. Schrock that the new tank battery would have to meet the current urban regulations regarding, fencing and signage. Mr. Schrock said All the deficiencies will be corrected with the new tank battery. No violations at this inspection were indentified.
1892470323 2009-04-01 Production Wells No Violations The last reported production from this well was in 2006. Goodyear still has five wells on their bond that I will discuss in a letter to them regarding plans to plug or produce.
683581326 2016-12-5 0:00: UP No Violations
PL4590 PL No Violations

For data sources see[9]