34-151-25795

Well Details

Well ID: 34-151-25795
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Osnaburg Township
Operator Name: C & T ENERGY OF EAST CANTON IN
Well Pad ID:
Farm/Lease Name: BEVINGTON
License Status: Producing
License Date: 2012-05-02
Spud Date: 2012-05-11
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2012-05-15
Well Total Depth: 4957.00 ft
Configuration: Vertical
Latitude: 40.790000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-05-02 Proposed Formations:CLINTON, Issued Date:5/2/2012, Expired Date:5/2/2014 12:00:00 PM, Drilling unit acres:58.74, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2012-05-15
Completion Report Received 2012-09-12
Construction Permit Expires 2013-05-02
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-09-20 4733 4777 43
4733 4777 43
4733 4777 43

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-05-30 H2O 7 137000 Gal 80000 Superior Well Services 76 perforations, no significant pressure changes, no fluid observed from the annulus. Pump truck manifold failure at 27550 gal. repaired on location, continued with job.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 C & T ENERGY OF EAST CANTON IN 226.00 187.00 61
2013 C & T ENERGY OF EAST CANTON IN 1327.00 876.00 365
2014 C & T ENERGY OF EAST CANTON IN 1094.00 854.00 365
2015 C & T ENERGY OF EAST CANTON IN 1188.00 477.00 365
2016 C & T ENERGY OF EAST CANTON IN 1105.00 492.00 365
2017 C & T ENERGY OF EAST CANTON IN 1187.00 497.00 365
2018 C & T ENERGY OF EAST CANTON IN 1257.00 478.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 C & T ENERGY OF EAST CANTON IN Brine 1590 61
2013 C & T ENERGY OF EAST CANTON IN Brine 1115 365
2014 C & T ENERGY OF EAST CANTON IN Brine 550 365
2015 C & T ENERGY OF EAST CANTON IN Brine 420 365
2016 C & T ENERGY OF EAST CANTON IN Brine 350 365
2017 C & T ENERGY OF EAST CANTON IN Brine 455 365
2018 C & T ENERGY OF EAST CANTON IN Brine 470 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1019891722 2012-5-30 0:00: CT No Violations
0148314546 2012-05-17 Drill / Deepen / Reopen No Violations I conducted an inspection of the drill site while on location to witness the cementing of the production string. Advent Drilling reached their total depth of 4957. The permit was displayed in the doghouse, there were no leaks or spills around the drilling equipment and there were no sags or tears in the pit liners. No violations at this time. See casing report for details of cement job.
1019891722 2012-05-30 Completion Testing No Violations I was on location to witness the perforating of the production casing and the frac job. Phoenix Well Svc. Perforated with 47 shots from 4733 to 4777. The original frac valve leaked during Superior Well Svcs pressure test. A new frac valve was brought in. The frac job was paused at 27550 gallons due to a pump truck manifold failure. The truck was repaired and the job continued. There were no significant pressure changes throughout the job and there were no leaks or spills. No violations.
1334803656 2014-08-19 Preliminary Restoration No Violations I was on location to pass preliminary restoration for this well. The lease road is graveled, in good condition and leads up to a pump jack well in good mechanical condition with proper gauges and locks. The tank battery is surrounded by a dike, has I.D. signage and contains a 210bbl production tank, 100bbl brine tank and a vertical separator. At this time preliminary restoration has been passed.
1337358564 2012-05-16 Drill / Deepen / Reopen No Violations On the day of my inspection I found that Advent Drilling was drilling the 7-7/8 production hole on air and soap. They were at a depth of 4611. The permit was displayed in the doghouse, there were no leaks or spills around the drilling equipment and there were no sags or tears in the pit liners. No violations at this time.
148314546 2012-5-17 0:00: DD No Violations

For data sources see[9]

References