34-151-22113

Well Details

Well ID: 34-151-22113
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Sandy Township
Operator Name: G & O RESOURCES LTD
Well Pad ID:
Farm/Lease Name: ROSIA F
License Status: Producing
License Date: 1970-04-23
Spud Date: 1970-04-22
Spud Drilling Contractor:
Final Drill Date: 1970-04-28
Well Total Depth: 5115.00 ft
Configuration: Vertical
Latitude: 40.680000
Longitude: -81.250000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1970-04-22 EB-974.6, KB-980.6
Completed 1970-04-28 EB-974.6, KB-980.6
Reached Total Depth 1970-04-28 EB-974.6, KB-980.6
Change of Owner 1997-08-25 Operator changed from 4280, JRD ENERGY to 5894, G & O RESOURCES LTD
Record Last Modified 2013-10-03 EB-974.6, KB-980.6

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4962 5056 0
4962 5056 0
4962 5056 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 29300

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1994 JRD ENERGY 0.00 0.00 365
1995 JRD ENERGY 0.00 90.00 365
1996 JRD ENERGY 0.00 195.00 365
1997 JRD ENERGY 0.00 90.00 197
1998 G & O RESOURCES LTD 0.00 223.00 365
1999 G & O RESOURCES LTD 0.00 159.00 90
2000 G & O RESOURCES LTD 0.00 93.00 60
2001 G & O RESOURCES LTD 0.00 112.00 365
2002 G & O RESOURCES LTD 0.00 155.00 365
2003 G & O RESOURCES LTD 0.00 74.00 365
2004 G & O RESOURCES LTD 0.00 67.00 365
2005 G & O RESOURCES LTD 0.00 119.00 365
2006 G & O RESOURCES LTD 0.00 51.00 365
2007 G & O RESOURCES LTD 0.00 0.00 0
2008 G & O RESOURCES LTD 0.00 147.00 366
2009 G & O RESOURCES LTD 0.00 0.00 0
2010 G & O RESOURCES LTD 0.00 65.00 365
2011 G & O RESOURCES LTD 0.00 71.00 365
2012 G & O RESOURCES LTD 0.00 0.00 0
2013 G & O RESOURCES LTD 0.00 47.00 365
2014 G & O RESOURCES LTD 0.00 0.00 0
2015 G & O RESOURCES LTD 0.00 0.00 0
2016 G & O RESOURCES LTD 0.00 0.00 0
2017 G & O RESOURCES LTD 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1994 JRD ENERGY Brine 0 365
1995 JRD ENERGY Brine 0 365
1996 JRD ENERGY Brine 81 365
1997 JRD ENERGY Brine 102 197
1998 G & O RESOURCES LTD Brine 603 365
1999 G & O RESOURCES LTD Brine 192 90
2000 G & O RESOURCES LTD Brine 151 60
2001 G & O RESOURCES LTD Brine 155 365
2002 G & O RESOURCES LTD Brine 135 365
2003 G & O RESOURCES LTD Brine 105 365
2004 G & O RESOURCES LTD Brine 46 365
2005 G & O RESOURCES LTD Brine 68 365
2006 G & O RESOURCES LTD Brine 38 365
2007 G & O RESOURCES LTD Brine 0 0
2008 G & O RESOURCES LTD Brine 0 366
2009 G & O RESOURCES LTD Brine 46 0
2010 G & O RESOURCES LTD Brine 0 365
2011 G & O RESOURCES LTD Brine 0 365
2012 G & O RESOURCES LTD Brine 0 0
2013 G & O RESOURCES LTD Brine 0 365
2014 G & O RESOURCES LTD Brine 0 0
2015 G & O RESOURCES LTD Brine 6 0
2016 G & O RESOURCES LTD Brine 0 0
2017 G & O RESOURCES LTD Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1006331438 2020-2-20 0:00: PW No Violations 0.80
-1493809226 2019-4-15 0:00: PW No Violations 0.60
-188430917 2016-3-8 0:00:0 PW No Violations
-2092763925 2015-8-3 0:00:0 PW No Violations 1.00
0188430917 2016-03-08 Production Wells No Violations I conducted an inspection on this well as a follow-up to a request from the Stark County engineers office. The wellhead had a pumpjack on it and the valves on the wellhead were open. There was water around the 8 and 5/8 inch casing and the water had a thin layer of oil on it and was bubbling indicating a leak from the wellhead. The tank battery consisted of a 100 BBL production tank, a 50 BBL steel brine tank and mechanical separator. The well identification sign was legible and mounted at the tank battery. The access to the tank battery and wellhead was stable. I contacted G&O Resourcces Ltd who was sending out the pumper, Mark Shubert to remedy the leak at the wellhead. I will reinspect this well in two weeks.
1230458774 2014-01-17 Production Wells No Violations I was on location to follow up on a compliance notice for this well regarding complaint #4577. The Stark County Engineers Office called to report that while one of their bridge engineers were inspecting a bridge, he discovered an exposed oil and gas line leaking gas. The line crosses a creek and the creek is bubbling where the line was leaking. The well pumper Dave Widduck shut in the tubing and the leak stopped. They are also going to be planning to plug this well. We have agreed to have the flow lines removed from the well to the tank battery, which will no longer provide a pathway for gas to enter the stream if gas flow was to occur again. They are going to be removing the flow lines to ensure that the well cannot contaminate the creek at this time. The compliance notice can be now passed at this time as the contamination and leaking from the well has stopped. I will be following up on this well when the flow lines are removed when the weather improves and the well is plugged. There are no violations for this well at this time.
1389885554 2014-01-15 Production Wells Violations Noted I was on location to check on complaint #4577. The Stark County Engineers Office called to report that while one of their bridge engineers were inspecting a bridge, he discovered an exposed oil and gas line leaking gas. The line crosses a creek and the creek is bubbling where the line is leaking. He wasnt sure if that was the well owner. I was able to identify this well as the well providing the gas leak. I contacted Chuck Will (330-805-0181) and he said that the well had been shut in and that it could not be leaking. I insisted he send someone to the well to check on it. The pumper Dave Widduck confirmed that the well was shut in, but the tubing was not shut in. This was causing gas to still flow through the line, which was under the bridge in the creek. They shut in the tubing and the leak stopped. They are also going to be planning to plug this well. We have agreed to have the flow lines removed from the well to the tank battery, which will no longer provide a pathway for gas to enter the stream. They are going to be removing the flow lines this week and ensure that the well cannot contaminate the creek at this time. A compliance notice has been given to the operator and will be passed when full remediation occurs. Dave Widduck will contact me when the flow lines are removed so that I can verify that the work has been done and the compliance notice passed.
1493809226 2019-04-15 Production Wells No Violations My inspection found the well is not plugged as requested by the Compliance Notice issued on 01-09-2019. The well is shut in. The water ponding around the wellhead shows it is leaking gas below ground level. The application history shows no Plug and Abandon permit being issued at this time. I phoned 330-253-0620 (G & O Office) and left a message for a return call. The tank battery consists of a steel production tank, a steel brine tank, a vertical separator and a meter.
1547124833 2019-01-09 Production Wells Violations Noted My inspection found the well is equipped with a pumpjack. The well is shut in and the flowlines are disconnected. The well last produced in 2013 for 47 barrels of oil. The well has zero production reported from 2014 through 2017. The tank battery consists of steel tank, a vertical separator and a meter. The well is legibly identified. I called 330-761-3508 and it went to a fax machine. This well is idle. Consequently, the well is in violation of Revised code 1509.062 and shall be plugged in accordance with Ohio Revised Code section 1509.12 (B). The well owner/operator shall submit a written plugging schedule to Shawn Murphy at 3575 Forest Lake Dr., Ste. 150, Uniontown, Ohio 44685 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
1558545229 2019-12-5 0:00: PW No Violations 0.60
2092763925 2015-08-03 Production Wells No Violations I was on location to perform an inspection of this production well at request of the landowner. The lease road is stable. The tank battery contains a 100bbl production tank, 50bbl brine tank, vertical separator and has new identification posted. The electrically driven pumpjack wellhead is currently shut in and overgrown. The electric box is disconnected. A new bridge is being built near the access road and the flowlines for the well have been removed while the construction is being completed. I have contacted Bill Lavin of G&O and they are going to evaluate the well to either plug or put the well back into production following the site construction. This well produced 47bbls of oil in 2013.
71103849 2020-4-23 0:00: PW No Violations 0.70

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1389885554 US-OH-111526 2014-02-05 Inadequate pipeline strength
1389885554 US-OH-111527 2014-02-05 Well operation causing pollution and contamination
1547124833 US-OH-115012 2019-01-15 NONE Well shall be plugged

For data sources see[9]