X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-151-22088

Well Details

Well ID: 34-151-22088
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Osnaburg Township
Operator Name: WILLIAM S MILLER INC
Well Pad ID:
Farm/Lease Name: FOLTZ DR
License Status: Active Injection
License Date: 1995-07-17
Spud Date: 1969-12-08
Spud Drilling Contractor: FLANIGAN BROS
Final Drill Date: 1969-12-15
Well Total Depth: 5240.00 ft
Configuration: Vertical
Latitude: 40.740000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1969-11-21 146 FOLTZ & FOLTZ ENTP GeoDate 11/21/69
Original Spud 1969-12-08 CONVERTED TO SWIW CONVERT 7-22-95
Completed 1969-12-15 CONVERTED TO SWIW CONVERT 7-22-95
Reached Total Depth 1969-12-15 CONVERTED TO SWIW CONVERT 7-22-95
CO 1995-07-17 146 FOLTZ & FOLTZ ENTP GeoDate 7/17/95
Conversion to Injector 1995-07-17
Salt Water Injection Well 1995-07-17 Issued Date 7/17/95 Expired Date 7/16/96 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth Proposed Drill Depth
Storage Well 1995-07-17 Issued Date 7/17/95 Expired Date 7/16/96 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth Proposed Drill Depth
Construction Permit Expires 1996-07-16 CONVERTED TO SWIW CONVERT 7-22-95
Annulus Pressure Monitoring Approved 1996-08-15 CONVERTED TO SWIW CONVERT 7-22-95
First Injection 1996-10-26 CONVERTED TO SWIW CONVERT 7-22-95
Last Compliance Report 2010-09-13 CONVERTED TO SWIW CONVERT 7-22-95
Change of Owner 2017-12-20 Operator changed from 146, FOLTZ & FOLTZ LTD PARTNERSHIP to 2512, WILLIAM S MILLER INC
Record Last Modified 2017-12-20 CONVERTED TO SWIW CONVERT 7-22-95

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-08 5078 5120 3
5078 5120 3
5078 5120 3

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0
H2O 0 1350 Bbl 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 FOLTZ & FOLTZ LTD PARTNERSHIP 701.00 439.00 0
1986 FOLTZ & FOLTZ LTD PARTNERSHIP 613.00 50.00 365
1987 FOLTZ & FOLTZ LTD PARTNERSHIP 569.00 421.00 365
1988 FOLTZ & FOLTZ LTD PARTNERSHIP 745.00 552.00 365
1989 FOLTZ & FOLTZ LTD PARTNERSHIP 522.00 473.00 365
1990 FOLTZ & FOLTZ LTD PARTNERSHIP 408.00 307.00 365
1991 FOLTZ & FOLTZ LTD PARTNERSHIP 483.00 169.00 365
1992 FOLTZ & FOLTZ LTD PARTNERSHIP 508.00 426.00 365
1993 FOLTZ & FOLTZ LTD PARTNERSHIP 597.00 163.00 365
1994 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 54.00 365
1995 FOLTZ & FOLTZ LTD PARTNERSHIP 626.00 208.00 365
1996 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 0
1986 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
1987 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
1988 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 118 365
1989 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 436 365
1990 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 156 365
1991 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 450 365
1992 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 449 365
1993 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 320 365
1994 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 311 365
1995 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 113 365
1996 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 175 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1096621159 2017-11-13 0:00 SW No Violations 0.50
-1132963910 2020-1-14 0:00: SW No Violations 1.00
-1242940138 2006-2-28 0:00: SW No Violations
-1258453828 2007-12-18 0:00 SW No Violations
-1307835295 2018-7-16 0:00: SW No Violations
-1344365763 2004-9-21 0:00: SW No Violations
-1382148948 2009-4-1 0:00:0 SW No Violations
-1409691297 2010-6-10 0:00: SW No Violations
-1520220138 2015-6-26 0:00: SW No Violations
-1529790725 2019-4-18 0:00: SW No Violations 0.70
-1588115722 2018-6-12 0:00: SW No Violations 1.30
-1629367530 2007-6-27 0:00: SW No Violations
-1643047446 2011-5-19 0:00: SW No Violations
-1675396498 2019-1-17 0:00: SW No Violations 0.50
-1718580381 2017-12-15 0:00 SW No Violations 0.70
-181122561 2004-3-25 0:00: SW No Violations
-1866543091 2018-10-31 0:00 SW No Violations 1.50
-1908430186 2003-9-4 0:00:0 SW No Violations
-1923593587 2014-3-31 0:00: SW No Violations
-1953951638 2002-10-16 0:00 SW No Violations 1.00
-1964058981 2020-2-27 0:00: SW No Violations 0.50
-2023857524 2017-11-28 0:00 SW No Violations 0.80
-2070995401 2006-5-23 0:00: SW No Violations
-255525453 2019-8-7 0:00:0 SW No Violations 0.60
-260278483 2010-9-9 0:00:0 SW No Violations
-269507628 2013-6-25 0:00: SW No Violations
-389380482 2006-8-30 0:00: SW No Violations
-441970638 2015-9-23 0:00: SW No Violations
-564310352 2005-12-14 0:00 SW No Violations
-633302655 2010-3-30 0:00: SW No Violations
-681235898 2019-10-22 0:00 SW No Violations 0.50
-752434915 2019-5-20 0:00: SW No Violations
-770794539 2010-12-22 0:00 SW No Violations
-774169683 2016-3-24 0:00: SW No Violations
-809565946 2007-3-13 0:00: SW No Violations
-810141537 2002-10-16 0:00 SW No Violations 1.00
-84957931 2009-9-4 0:00:0 SW No Violations
-851401964 2014-9-26 0:00: SW No Violations
-968512676 2015-3-31 0:00: SW No Violations
-982846214 2010-8-17 0:00: SW No Violations
-997293857 2006-2-28 0:00: SW No Violations
00001288i5 Salt Water Injection Well No Violations injection pressure 0 psi annulus pressure 20 psi , no violations at this time
0001288i76 2001-10-01 Salt Water Injection Well No Violations Injection : 0 Annulus :20  ; last inspection on 8/28/01 .
001288i190 2002-01-04 Salt Water Injection Well No Violations Injection : 0  ; Annulus : 20 No violations at this time . Last inspection on 12 / 11 / 2001 .
001288i224 2001-12-11 Salt Water Injection Well No Violations Injection : 0  ; Annulus  : 20  ; Last inspection : 10/01/01 . No violations at this time .
001288i289 2002-02-20 Salt Water Injection Well No Violations Injection : 0  ; Annulus  : 20  ; Last inspection  : 01 / 04 / 02 . No violations at this time .
001288i378 2002-03-19 Salt Water Injection Well No Violations Injection : 0  ; Annulus : 20  ; Last inspection on 02 / 20 / 02 . No violations at this time .
001288i489 2002-04-30 Salt Water Injection Well No Violations Injection : 0  ; Annulus : 20  ; Last inspection on 03 / 19 / 02 . No violations at this time .
0084236943 2010-12-22 Salt Water Injection Well Violations Noted The injection system was not running at the time of the inspection. The injection line was leaking at a line clamp near the wellhead. There was soil contamination from the brine leak and from the recent well servicing for the packer repair. A temporary pit near the access road was overflowing. I called Bob Foltz and told him to shut down the facility, replace the injection line, remove the contaminated soils, clean up the site, and close the temporary pit immediately.
0084957931 2009-09-04 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. An oil release is being cleaned up within the lined brine pit dike near the injection pump shed. The discharge line from the groundwater sump has been replaced, but the excavation has not been backfilled.
0121749656 2005-06-08 Salt Water Injection Well No Violations NO VIOLATIONS. The disposal facility was not running at the time of the inspection.
0130447306 2016-12-28 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations at the time.
0172586473 2018-08-29 Salt Water Injection Well No Violations I found the injection well in operation on the day of my inspection. There was no facility operator on location. An identification sign is hanging from the injection line at the well. New clean gravel has been spread around the open pits and access road. I observed no spills or leaks.
0181122561 2004-03-25 Salt Water Injection Well No Violations The system was not running at the time of the inspection. NO VIOLATIONS.
0244379690 2006-01-31 Salt Water Injection Well No Violations Still needs I.D. sign.
0260278483 2010-09-09 Salt Water Injection Well No Violations A rebuilt R-4 packer was run on 2-3/8 dia external upset tubing and set in tension with 44,000 lbs (this is 14,000 lbs over the string weight of 30,000 lbs) at a depth of 5041.60. Annular inhibitor was placed in the annulus. An MIT was performed. 1210 psi was put on the annulus and held for 20 minutes. The pressure dropped to 1170 psi. The MIT PASSED. Bob Foltz will send a tubing tally to Tom Tomastik in Columbus.
0264891940 2017-03-27 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations at the time.
0269507628 2013-06-25 Salt Water Injection Well No Violations My inspection of the well and surface facility found no identification.

Post complete identification in a conspicuous place on or near the surface facility. The following information must be included: owners name, lease name, well number, permit number, county, township, and emergency telephone number.

0271506870 2016-03-08 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The wells caretaker was instructed to pressure up the annulus. There were no violations at the time.
0374168622 2010-09-03 Salt Water Injection Well No Violations Bob Foltz is treating the injection well today with 50 gallons of GYPSOL mixed with water.
0389380482 2006-08-30 Salt Water Injection Well No Violations The system was not running at the time of the inspection. There were no violations at the wellhead or at the tank battery.
0403227054 2004-06-22 Salt Water Injection Well No Violations The system was not running at the time of the inspection. NO VIOLATIONS.
0409998423 2007-09-26 Salt Water Injection Well No Violations The injection pump was not running at the time of the inspection. There were no violations at the wellhead or at the brine tanks. Bob Foltz was told to post a new I.D. sign at the wellhead or on the pump house door.
0441970638 2015-09-23 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The well was found shut-in. There were no violations found at the time.
0478004574 2003-05-22 Salt Water Injection Well No Violations Locate well and facility. Did not check pressures.
0523779483 2008-07-10 Salt Water Injection Well No Violations An I.D. sign has been posted at the facility. The N.O.V. has been RESOLVED.
0564310352 2005-12-14 Salt Water Injection Well No Violations Nothing has been done since the last N.O.V. follow-up inspection. Replace the injection line and post an I.D. sign.
0593403990 2016-09-19 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0603959036 2008-09-25 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. An I.D. sign has been placed on the pump house door. A crew was cleaning up a release from the 330 bbl tank that had been vandalized. The release was contained within the lined pit. The discharge line from the groundwater sump is also being replaced.
0626605812 2005-03-22 Salt Water Injection Well No Violations The system was not running at the time of the inspection. NO VIOLATIONS.
0633302655 2010-03-30 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. The groundwater sump discharge line excavation has not been backfilled.
0675549351 2017-06-30 Salt Water Injection Well No Violations I conducted a status check inspection on this well with Steve Ochs. The well legibly identified and no integrity issues are noted at this time. The Annulus pressure was less than 20
0677221333 2005-08-23 Salt Water Injection Well No Violations Discussed needle valve, I.D. sign, and ditched area near WH with Bob Foltz.
0753247219 2008-03-20 Salt Water Injection Well No Violations The system was running at the time of the inspection. Bob Foltz has not posted the I.D. sign that I requested.
0770794539 2010-12-22 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 84236943 The injection system was not running at the time of the inspection. The injection line was leaking at a line clamp near the wellhead. There was soil contamination from the brine leak and from the recent well servicing for the packer repair. A temporary pit near the access road was overflowing. I called Bob Foltz and told him to shut down the facility, replace the injection line, remove the contaminated soils, clean up the site, and close the temporary pit immediately.
0774169683 2016-03-24 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There was positive pressure on the annulus. There were no violations found at the time.
0809565946 2007-03-13 Salt Water Injection Well Violations Noted The system was not running at the time of the inspection. The hammer union and the 45 degree elbow on the injection line at the wellhead are leaking. There is no I.D. sign at the wellhead. I called Bob Foltz and informed him to repair the injection line and to place an I.D. sign at the wellhead.
0810141537 2002-10-16 Salt Water Injection Well No Violations Routine inspection revealed no violations at this time .
0834016081 2018-02-15 Salt Water Injection Well No Violations I was on location to inspect the UIC well and facility and assess compliance notice # -1718580381. I found the well operating on the day of my inspection. There was no facility operator on location. The gravel around the two (2) steel open brine tanks are stained from oil and brine. A new identification has been posted on the injection well. I spoke with George Miller, new owner of the UIC facility. Mr. Miller stated the company plans to clean-
0851401964 2014-09-26 Salt Water Injection Well Violations Noted The well owner was instructed to replace the broken needle valve on the casing and put a minimum pressure of 200 psi. on the tubing/casing annulus.
0870625336 2009-05-28 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. The discharge line from the groundwater sump has been replaced, but the excavation has not been backfilled.
0881547583 2014-06-16 Salt Water Injection Well No Violations No violations were found at the time.
0968512676 2015-03-31 Salt Water Injection Well Violations Noted The 1/4 inch valve on the casing was broke. A company representative was instructed to replace the 1/4 inch valve on the casing and put around 200 psi. of pressure on the tubing/casing annulus.
0982846214 2010-08-17 Salt Water Injection Well No Violations A rebuilt R-4 packer was run on tubing and set in tension with 45,000 lbs (this is 15,000 lbs over the string weight of 30,000 lbs) at a depth of 5042.58. Annular inhibitor was placed in the annulus. An MIT was performed. 1220 psi was put on the annulus and held for 20 minutes. The pressure dropped to 1200 psi. The MIT PASSED. Bob Foltz will send a tubing tally to Tom Tomastik in Columbus.
0997293857 2006-02-28 Salt Water Injection Well No Violations An I.D. sign has been placed at the wellhead. N.O.V. has been RESOLVED.
0997384614 2013-09-30 Salt Water Injection Well No Violations My inspection of the well and injection facility found identification stenciled onto a tank.
1031813343 2016-08-11 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1037117276 2008-12-17 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. The discharge line from the groundwater sump has been replaced, but the excavation has not been backfilled.
1043730403 2007-10-30 Salt Water Injection Well No Violations The system was not running at the time of the inspection. Bob Foltz has not posted the I.D. sign that I requested.
1096621159 2017-11-13 Salt Water Injection Well No Violations I was on location to inspect the injection well. There is oil stain soil on the north side of the two (2) open air tanks within the diked UIC tank battery. The stenciled identification sign on a storage tank is partially faded and has no permit number. I found no spills or leaks. I left a message with Foltz & Foltz to return my call.
1103153699 2006-03-23 Salt Water Injection Well No Violations Needle valve still needs to be replaced.
1104017624 2009-12-04 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. The oil release within the lined brine pit dike near the injection pump shed has been completely remediated. The groundwater sump discharge line excavation has not been backfilled.
1169357352 2005-11-23 Salt Water Injection Well No Violations 8-5/8 casing valve leak has been repaired. Contaminated soil has been removed and is piled along side the lease road. Called Bob Foltz.
1178555972 2007-05-04 Salt Water Injection Well No Violations The injection line is still leaking brine and there is no I.D. sign at the wellhead.
121749656 2005-6-8 0:00:0 SW No Violations
1242940138 2006-02-28 Salt Water Injection Well No Violations The injection pump was not running at the time of the inspection. No Violations at WH or pit area. I was unable to check annular pressure because of a broken needle valve. I called Bob Foltz and he will replace the valve.
1258453828 2007-12-18 Salt Water Injection Well No Violations The system was not running at the time of the inspection. Bob Foltz has not posted the I.D. sign that I requested.
1281579150 2010-08-10 Salt Water Injection Well No Violations Bob Foltz, Adam, and I conducted an MIT. The MIT failed. Bob and Adam repacked the wellhead and we pressured up and tested again. The MIT failed. I told Bob to open the annulus to allow the air to purge out of the annular inhibiter and try a test tomorrow. If his test failed, I told Bob to unseat and reset the packer.
1288i190 2002-1-4 0:00:0 SW No Violations 1.00
1288i224 2001-12-11 0:00 SW No Violations 1.00
1288i289 2002-2-20 0:00: SW No Violations 1.00
1288i378 2002-3-19 0:00: SW No Violations 1.00
1288i489 2002-4-30 0:00: SW No Violations 1.00
1288i5 SW No Violations
1288i76 2001-10-1 0:00: SW No Violations 1.00
1302661538 2011-04-12 Salt Water Injection Well No Violations Bob Foltz called me this morning for a MIT. When I arrived at the site a new Baker Lockset packer was set at 4979.95 and the annulus was pressured up to 1100 psi. I requested additional pressure on the annulus and started the test. The test was started at 1180 psi and ended at 1175 psi after 22 minutes. The MIT PASSED. Bob Foltz will send a copy of the tubing tally to Tom Tomastik. In regard to the N.O.V., the injection line has been replaced. The removal of the contaminated soils, the clean up of the site, and the closure of the temporary pit is in progress.
130447306 2016-12-28 0:00 SW No Violations
1307835295 2018-07-16 Salt Water Injection Well No Violations I found the injection well not operating on the day of my inspection. An identification sign is posted. I observed no spills or leaks. I spoke to George Miller on location.
1319228151 2011-10-18 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. The flow line leak has been repaired. In regard to the N.O.V. of 12-22-2010, the closure of the temporary pit is completed. Still have to clean up the debris around the wellhead and post a new I.D. sign.
1344365763 2004-09-21 Salt Water Injection Well No Violations NO VIOLATIONS. The system was not running at the time of the inspection.
1382148948 2009-04-01 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. The discharge line from the groundwater sump has been replaced, but the excavation has not been backfilled.
1409691297 2010-06-10 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. The groundwater sump discharge line excavation has not been backfilled.
1454921757 2006-01-03 Salt Water Injection Well No Violations Injection line has been replaced. Still needs I.D. sign.
1509464572 2019-3-11 0:00: SW No Violations 1.00
1520220138 2015-06-26 Salt Water Injection Well No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
1529073593 2018-06-15 Salt Water Injection Well No Violations I was on location to assess compliance notice # -
1585760602 2020-4-1 0:00:0 SW No Violations
1588115722 2018-06-12 Salt Water Injection Well Violations Noted

-up of the oil has already begun.

I spoke with George Miller: Mr. Miller stated the spill happened yesterday, 6/11/2018. Mr. Miller stated he accidently overflowed the storage tank while on site and started clean-up immediately. Mr. Miller stated he plans to bring in a steam truck to finish cleaning up the oil spill.

I informed Mr. Miller a compliance notice would be issued. Photos have been taken and are available upon request.

1594296226 2020-5-26 0:00: SW No Violations 1.00
1598375212 2020-8-25 0:00: SW No Violations 0.70
1629367530 2007-06-27 Salt Water Injection Well No Violations The system was not running at the time of the inspection. The injection pump was down for repairs. The injection line leak has been repaired since the last inspection. An I.D. sign still needs to be posted. The injection pressure and the annulus pressure were both 420 psi. I discussed this with Bob Foltz. I will test the pressures again when the injection pump is up and running.
1643047446 2011-05-19 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. The hammer union near the wellhead on the recently replaced injection line was dripping. I called Bob Foltz and told him to replace the hammer union. In regard to the N.O.V. of 12-22-2010, the closure of the temporary pit is 90% completed. I told Bob to finish the pit closure and to continue with the removal of the contaminated soils. I also told Bob to clean up the site and to establish vegetation.
1656631380 2005-01-04 Salt Water Injection Well No Violations The system was not running at the time of the inspection. NO VIOLATIONS.
1718580381 2017-12-15 Salt Water Injection Well No Violations The proper identification sign has not been posted per my request to Robert Foltz on 11/28/17. A compliance notice has been issued. A new identification sign needs posted by 12/29/17.
172586473 2018-8-29 0:00: SW No Violations 1.00
1761663074 2018-12-07 Salt Water Injection Well No Violations I found the injection well not operating on the day of my inspection. There was no facility operator on location. An identification sign is posted. I observed no spills or leaks.
1844333368 2016-06-22 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1866543091 2018-10-31 Salt Water Injection Well No Violations I found the injection well not operating on the day of my inspection. I observed no spills or leaks. An identification sign is posted on the injection well.
1885154201 2005-11-14 Salt Water Injection Well Violations Noted The system was not running at the time of the inspection. The hammer union on the 2 dia injection line near the wellhead had a slow leak; replace it. The 2 dia injection line is heavily corroded; replace it before it fails. Oil and brine were observed around the wellhead and the release was moving south to the gravel access road. I could hear and see fluid gurgling up from what appeared to be the buried 8-5/8 casing or casing valve. Excavate the area to find the leak. Repair the leak and remove any contaminated soil and vegetation. Place an I.D. sign at the wellhead. Called Bob Foltz (cell # 330-417-6433) and discussed the findings.
1908430186 2003-09-04 Salt Water Injection Well No Violations Facility was running at the time of the inspection. NO VIOLATIONS.
1923593587 2014-03-31 Salt Water Injection Well No Violations The were no violations found at the time of inspection.
1953951638 2002-10-16 Salt Water Injection Well No Violations Routine inspection revealed no violations at this time .
2023857524 2017-11-28 Salt Water Injection Well No Violations I found the faded stencil identification sign not updated. I spoke with an answering service for Foltz & Foltz, then with Robert Foltz. I told Mr. Foltz to update the faded stencil identification sign by 12/13/17. Mr. Foltz stated the identification sign would be completed by 12/8/17.
2049287860 2008-06-12 Salt Water Injection Well No Violations The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the steel brine pits. The I.D. sign at the wellhead is still missing and needs to be replaced.
2070995401 2006-05-23 Salt Water Injection Well No Violations The system was not running at the time of the inspection. There were no violations at the wellhead or at the tank battery. A new needle valve has been replaced on the annulus.
244379690 2006-1-31 0:00: SW No Violations
264891940 2017-3-27 0:00: SW No Violations
271506870 2016-3-8 0:00:0 SW No Violations
374168622 2010-9-3 0:00:0 SW No Violations
403227054 2004-6-22 0:00: SW No Violations
409998423 2007-9-26 0:00: SW No Violations
467056253 2020-4-10 0:00: SW No Violations
478004574 2003-5-22 0:00: SW No Violations
523779483 2008-7-10 0:00: SW No Violations
541419069 2020-7-17 0:00: SW No Violations 1.00
593403990 2016-9-19 0:00: SW No Violations
603959036 2008-9-25 0:00: SW No Violations
626605812 2005-3-22 0:00: SW No Violations
675549351 2017-6-30 0:00: SW No Violations 0.70
677221333 2005-8-23 0:00: SW No Violations
753247219 2008-3-20 0:00: SW No Violations
834016081 2018-2-15 0:00: SW No Violations 1.20
84236943 2010-12-22 0:00 SW No Violations
870625336 2009-5-28 0:00: SW No Violations
881547583 2014-6-16 0:00: SW No Violations
997384614 2013-9-30 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0084236943 US-OH-129590 2010-12-22 Pollution/Contamination
0084236943 US-OH-129591 2010-12-22 Mechanical failure/contamination
0809565946 US-OH-129215 2007-03-14 Permit not displayed
0809565946 US-OH-129216 2007-03-14 Mechanical failure/contamination
0851401964 US-OH-129685 2014-10-06 Violation of injection tubing/fitting requirements
0968512676 US-OH-131107 2015-04-23 Violation of injection tubing/fitting requirements
1588115722 US-OH-115535 2018-10-16 9-3-04(A) Pollution/Contamination
1885154201 US-OH-118931 2005-11-14 Pollution/Contamination
1885154201 US-OH-118932 2005-11-15 Inadequate/Insufficient surface casing
1885154201 US-OH-118933 2005-11-14 Permit not displayed

For data sources see[9]

References