X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-133-24115

Well Details

Well ID: 34-133-24115
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Atwater Township
Operator Name: PEP DRILLING LLC
Well Pad ID:
Farm/Lease Name: REESE UNIT # 1
License Status: Producing
License Date: 1997-04-21
Spud Date: 1997-05-22
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 1997-06-04
Well Total Depth: 7517.00 ft
Configuration: Vertical
Latitude: 41.050000
Longitude: -81.180000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1997-04-21 Issued Date 4/21/97 Expired Date 4/21/98 Acres 0040000 Tool Type RTAF Proposed Formation ROSE RUN Proposed Depth Proposed Drill Depth
Original Spud 1997-05-22 RBDMS Rec
Completed 1997-06-04 RBDMS Rec
Reached Total Depth 1997-06-04 RBDMS Rec
Completion Report Received 1997-07-22 RBDMS Rec
Change of Owner 2016-03-04 Operator changed from 1198, PIPES PURSIE E to 9640, PEP DRILLING LLC
Record Last Modified 2019-06-14 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-09-25 7342 7392 0
7342 7392 0
7342 7392 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2150 Bbl 36000 1000 GAL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1997 PIPES PURSIE E 36068.00 2247.00 365
1998 PIPES PURSIE E 54803.00 10802.00 365
1999 PIPES PURSIE E 23354.00 4941.00 365
2000 PIPES PURSIE E 16858.00 2239.00 365
2001 PIPES PURSIE E 26454.00 2275.00 365
2002 PIPES PURSIE E 23055.00 1502.00 365
2003 PIPES PURSIE E 26808.00 1012.00 365
2004 PIPES PURSIE E 7412.00 467.00 365
2005 PIPES PURSIE E 3271.00 280.00 365
2006 PIPES PURSIE E 3031.00 159.00 365
2007 PIPES PURSIE E 2435.00 226.00 365
2008 PIPES PURSIE E 1605.00 102.00 365
2009 PIPES PURSIE E 1949.00 192.00 365
2010 PIPES PURSIE E 63.00 0.00 365
2011 PIPES PURSIE E 136.00 78.00 365
2012 PIPES PURSIE E 3.00 85.00 366
2013 PIPES PURSIE E 68.00 0.00 365
2014 PIPES PURSIE E 89.00 59.00 365
2016 PEP DRILLING LLC 91.00 0.00 365
2017 PEP DRILLING LLC 148.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1997 PIPES PURSIE E Brine 4240 365
1998 PIPES PURSIE E Brine 3690 365
1999 PIPES PURSIE E Brine 3585 365
2000 PIPES PURSIE E Brine 3220 365
2001 PIPES PURSIE E Brine 3335 365
2002 PIPES PURSIE E Brine 2195 365
2003 PIPES PURSIE E Brine 2520 365
2004 PIPES PURSIE E Brine 2745 365
2005 PIPES PURSIE E Brine 2090 365
2006 PIPES PURSIE E Brine 2720 365
2007 PIPES PURSIE E Brine 2115 365
2008 PIPES PURSIE E Brine 1755 365
2009 PIPES PURSIE E Brine 1850 365
2010 PIPES PURSIE E Brine 1580 365
2011 PIPES PURSIE E Brine 1920 365
2012 PIPES PURSIE E Brine 1300 366
2013 PIPES PURSIE E Brine 1395 365
2014 PIPES PURSIE E Brine 1640 365
2016 PEP DRILLING LLC Brine 0 365
2017 PEP DRILLING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-162708362 2009-12-14 0:00 PW No Violations
-901368523 2010-1-13 0:00: PW No Violations
0125801633 2003-04-01 Production Wells Violations Noted Status check inspection. There was oil impact outside of the dike on the west side of the tank battery and on the west side of the pump jack. Neither the wellhead nor the tank battery were leaking at the time of this inspection. However, some peatsorb had been placed around the wellhead in an attempt to contain the spill. I contacted Mark Smith (330-808-0716) with PEP and requested that both spills be remediated immediately.
0162708362 2009-12-14 Production Wells No Violations Follow up inspection to see if the requested fence had been placed around the well and tank battery. Atwater is not an urban township and fencing is not required. However, I asked PEP to install fencing due to recent increase in activity on the property. To date, no work has been completed.
0320398442 2018-05-09 Preliminary Restoration No Violations Status check inspection of this Rose Run Sandstone well. My inspection found the wellhead equipped with 2.375 tubing and rods and operating with the aid of a natural gas powered pumping unit. The valves on the tubing and the 4.5 production casing are open. This well produces to a diked tank battery on location and contains three (3) 210 barrel tanks, a vertical separator, and the associated meter run. A Murphy gauge at the separator indicates a pressure of 120psi and there are three (3) domestic taps on the sales line charged at 15psi. The required ID is posted at the wellhead and at the tank battery. No violations.
0901368523 2010-01-13 Production Wells No Violations The requested fence around the tank battery and the wellhead has not been installed. Follow-up contact will be made.
1096488636 2003-05-20 Production Wells No Violations The pollution violation has been corrected.
125801633 2003-4-1 0:00:0 PW No Violations
320398442 2018-5-9 0:00:0 PL No Violations 0.40
iDIAN00039 1998-07-27 Preliminary Restoration No Violations
iDIAN000395 1998-7-27 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0125801633 US-OH-106952 2003-04-06 Well operation causing pollution and contamination

For data sources see[9]