34-133-24113

Well Details

Well ID: 34-133-24113
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Atwater Township
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: MCKNIGHT # 2-RR
License Status: Producing
License Date: 1997-04-21
Spud Date: 1997-04-28
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 1997-05-09
Well Total Depth: 7477.00 ft
Configuration: Vertical
Latitude: 41.050000
Longitude: -81.170000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1997-04-21 Issued Date 4/21/97 Expired Date 4/21/98 Acres 0040000 Tool Type RTAF Proposed Formation ROSE RUN Proposed Depth Proposed Drill Depth
Original Spud 1997-04-28 RBDMS Rec
Completed 1997-05-09 RBDMS Rec
Reached Total Depth 1997-05-09 RBDMS Rec
Completion Report Received 1997-06-16 RBDMS Rec
Change of Owner 2016-10-07 Operator changed from 2050, ORION PETRO CORP to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-08-18 7356 7362 3
7356 7362 3
7366 7374 3
7382 7388 3
7392 7404 4
1997-08-18 7382 7388 3
7356 7362 3
1997-08-18 7392 7404 4
1997-08-18 7366 7374 3

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 59220 Gal 30300 1000 gal 15% HCL acid

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1997 ORION PETRO CORP 49336.00 27358.00 0
1998 ORION PETRO CORP 21844.00 15990.00 365
1999 ORION PETRO CORP 22487.00 7648.00 365
2000 ORION PETRO CORP 14420.00 3717.00 365
2001 ORION PETRO CORP 8494.00 2323.00 365
2002 ORION PETRO CORP 12162.00 2097.00 365
2003 ORION PETRO CORP 14806.00 2084.00 365
2004 ORION PETRO CORP 16286.00 1608.00 365
2005 ORION PETRO CORP 11694.00 1126.00 365
2006 ORION PETRO CORP 9613.00 804.00 365
2007 ORION PETRO CORP 10272.00 750.00 365
2008 ORION PETRO CORP 7675.00 656.00 365
2009 ORION PETRO CORP 7366.00 764.00 365
2010 ORION PETRO CORP 5445.00 433.00 0
2011 ORION PETRO CORP 5598.00 457.00 0
2012 ORION PETRO CORP 4743.00 350.00 366
2014 ORION PETRO CORP 3530.00 224.00 365
2015 ORION PETRO CORP 3587.00 377.00 365
2016 ORION PETRO CORP 2127.00 143.00 273
2017 PIN OAK ENERGY PARTNERS LLC 370.00 0.00 365
2018 PIN OAK ENERGY PARTNERS LLC 354.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1997 ORION PETRO CORP Brine 4516
1998 ORION PETRO CORP Brine 3667 365
1999 ORION PETRO CORP Brine 2844 365
2000 ORION PETRO CORP Brine 2289 365
2001 ORION PETRO CORP Brine 2033 365
2002 ORION PETRO CORP Brine 3069 365
2003 ORION PETRO CORP Brine 2673 365
2004 ORION PETRO CORP Brine 2500 365
2005 ORION PETRO CORP Brine 1907 365
2006 ORION PETRO CORP Brine 1983 365
2007 ORION PETRO CORP Brine 1706 365
2008 ORION PETRO CORP Brine 1445 365
2009 ORION PETRO CORP Brine 1692 365
2010 ORION PETRO CORP Brine 1483 0
2011 ORION PETRO CORP Brine 1546
2012 ORION PETRO CORP Brine 1344 366
2014 ORION PETRO CORP Brine 1670 365
2015 ORION PETRO CORP Brine 2200 365
2016 PIN OAK ENERGY PARTNERS LLC Brine 0 365
2017 PIN OAK ENERGY PARTNERS LLC Brine 50 365
2018 PIN OAK ENERGY PARTNERS LLC Brine 18 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1449524817 2017-9-26 0:00: PW No Violations 2.00
-1581424210 2005-3-14 0:00: PW No Violations
-1904592371 2017-9-19 0:00: PW No Violations 1.30
-1942129359 2017-8-22 0:00: PW No Violations 3.00
-1955951383 2017-9-20 0:00: PW No Violations 0.90
-553393502 2017-10-20 0:00 PW No Violations 0.60
-572267958 2017-8-28 0:00: AM No Violations 0.50
0150689981 2003-04-01 Production Wells Violations Noted Status check inspection - the well operation is causing pollution around the wellhead. The cause may have been stuffing box leak. There does appear to have been some attempt to clean up the spill. There is still impacted soil north and east of the wellhead. The tank battery for this well is in good condition. I contacted Buzz West with Orion to discuss the operation of this well.
0209490726 2017-09-25 Production Wells No Violations I was on location with DOGRM District Supervisor Steve Ochs to follow-up on Compliance Notice #-1942129359. A load of clean fill dirt has been dumped southwest of the tank battery. The two (2) 50 barrel, steel tanks have been steamed and are lying on their sides inside the tank battery. The 210 barrel tank has been steam cleaned and the vent stack has been removed. The well continues to sell natural gas and the chart at the sales meter was changed today. There is currently no activity on location. This violation continues.
0380351055 2003-04-18 Production Wells No Violations Pollution violation corrected. No other violations at this time.
0426077298 2017-09-06 Production Wells No Violations Follow-up to Compliance Notice #-1942129359. I extended the compliance date to 9/11/17 on 8/28/17 to accommodate the time required for soil testing to determine the proper disposal procedure. My inspection today found the location stable and no further migration of brine or oil away from containment. I will check back next week to see if remedial operations have commenced. This violation continues.
0553393502 2017-10-20 Production Wells No Violations Follow-up to Compliance Notice #-1942129359. My inspection found the tank battery has been rebuilt. The dump line from the separator has been plumbed to a 50 barrel tank. The dike walls on the west and north side of the battery have been rebuilt and the scalded areas outside of the dike have been remediated and seeded. New grass is beginning to re-establish in these areas. All the affected material has been removed and disposed of at Waste Managements American Landfill. This violation has been resolved.
0572267958 2017-08-28 Administrative Inspection No Violations I spoke with Pin Oak Operations Manager Ted Lawver today (8/28/17) concerning this well location and the time line for remedial activities. Ted told me that Lakeside would be taking soil samples this week for analysis to determine proper disposal procedures. He said that it would probably be 1-2 weeks before they receive the test results at which time they would proceed with clean-up operations. I have extended the remedy required date to 9/11/17.
1051658821 2019-12-23 0:00 PW No Violations 0.30
1449524817 2017-09-26 Production Wells No Violations Follow-up to Compliance Notice #-1942129359. Lakeside Oilfield (Ron Hammen) was on location continuing with clean-up operations. The good 50 barrel tank was spotted on the other side of the lease road for later use. The bad 50 barrel tank was placed in the back of a dump truck and the 210 barrel tank was strapped to the trailer. Both tanks were removed for disposal at a scrap yard. They are going to steam the rock in the tank battery and push it to a sump where it will be vacuumed out tomorrow. This violation continues.
1506531218 2017-09-27 Production Wells No Violations I was on location to oversee clean-up operations in reference to Compliance Notice #-1942129359. Lakeside Oilfield was on location and dug a sump at the west end of the battery and steamed the rock with 250 gallons of freshwater. J. Hawk Water Hauling was sucking the fluid out of the sump with their water truck. I tested the water in the sump with a Quantab and found it was over 1000ppm chlorides. I requested that steaming continue with the remaining 250 gallons of water. After flushing again, I tested the water and found it below 300ppm chlorides and excavation and removal of saturated materials began in and outside of the containment dike. Lime was spread on all of the excavated areas to buffer any residual chlorides and clean top soil was replaced where the saturated materials had been removed. The dike walls were rebuilt and the foot print of the battery was shrunk down. I will check back later on progress. This violation continues.
150689981 2003-4-1 0:00:0 PW No Violations
1525877287 2018-05-09 Production Wells No Violations Status check inspection of this Rose Run Sandstone well. My inspection found the wellhead equipped with 2.375 tubing and rods and a natural gas powered pumping unit. The tubing valve is currently closed and the 4.5 production casing valve is open. This well produces to a diked tank battery to the north that was remediated in the fall of 2017 and vegetation has been well established around the perimeter of the battery that was previously impacted by salt water. The battery contains one (1) 50 barrel tank, a vertical separator, and an associated meter run. There is a line heater between the wellhead and tank battery that is no longer in use and a domestic tap and meter is plumbed to the flow line at this point. A gauge on the line heater indicates a pressure of 140psi. The required ID is posted at the tank battery. No violations.
1581424210 2005-03-14 Production Wells No Violations Status check inspection - no vioaltions at this time.
1598979068 2020-9-1 0:00:0 PW No Violations 0.50
1904592371 2017-09-19 Production Wells No Violations Follow-up to Compliance Notice #-1942129359. My inspection today found that remedial activities have not yet been undertaken by Pin Oak Energy. The situation is static and there has been no further migration of the brine scald or oil inside containment. I spoke with operations manager Ted Lawver on Friday 9/15/17 and he told me that they finally received the results of the material testing and that they would begin remedial operations today or Wednesday 9/20/17. I will check back tomorrow to see if activities have started. This violation continues.
1942129359 2017-08-22 Production Wells Violations Noted Status check inspection of this Rose Run Sandstone well. My inspection found the wellhead equipped with a natural gas powered pumping unit. The well produces to a diked tank battery that contains one (1) 210 barrel tank, two (2) 50 barrel tanks, a vertical separator, drip bottle, and the associated meter run. There is a line heater between the wellhead and tank battery that is not in use. My inspection of the tank battery found an area measuring 18 wide and 30 long inside the central and north sides of the containment area that has been impacted by crude oil and brine. The rock is stained red and black and the staining reaches one (1) foot up the interior dike wall. There is coagulated crude oil sludge throughout and around the interior perimeter of the containment area. The western side of the containment area has standing water and thick, coagulated sludge. I ran a high range Quantab (Lot #5243) on a sample of the water. The Quantab unit value indicated 4.8 which corresponds to a chloride level of 1037ppm. Brine has migrated through and under the containment wall and impacted a 20x6 area on the north side, and 10x6 areas on the northwest and southwest corners. These areas have been scalded and are primarily devoid of vegetation. I spoke with Mark Van Tyne (Pin Oak Energy Partners), at 2:10pm, and informed him of my findings. I requested that the contaminated material be excavated and removed for disposal and the impacted areas be remediated. He said he is sending someone out to assess what remedial work will need to be done. Based on the appearance of the material inside the containment area and impact of the brine scalding damage, this was not a recent release and has been impacting the area in and around the tank battery for some time. DOGRM Emergency Response Coordinator Fred Rome arrived on location to assist me with the assessment. It had just rained and a high range Quantab was run in the standing water of a deer footprint in the 20x6 impact
1955951383 2017-09-20 Production Wells No Violations Follow-up to Compliance Notice #-1942129359. My inspection today found that remedial activities have not yet been undertaken by Pin Oak Energy. Ron Hammen from Lakeside Oilfield called this morning at 7:30am about starting clean-up operations at this location and the call was lost. They excavator is currently on location and the lease road has been graded and widened. I spoke with Ron again at 2:10pm and he will be in with the water truck in the morning to get the tank steamed out before moving it. I will check back on operations tomorrow (8/21/17). This violation continues.
209490726 2017-9-25 0:00: PW No Violations 0.50
380351055 2003-4-18 0:00: PW No Violations
426077298 2017-9-6 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0150689981 US-OH-114213 2003-04-06 Well operation causing pollution and contamination
1942129359 US-OH-119555 2017-09-14 Well operation causing pollution and contamination

For data sources see[9]

References