34-129-20232

Well Details

Well ID: 34-129-20232
Loading map...
Country: United States
State: Ohio
County: Pickaway
Municipality: Washington Township
Operator Name: R C POLING CO INC
Well Pad ID:
Farm/Lease Name: CROMAN UNIT
License Status: Final Restoration
License Date: 2010-07-01
Spud Date: 2011-04-14
Spud Drilling Contractor: BOWMAN DRILLING
Final Drill Date: 2011-04-21
Well Total Depth: 3115.00 ft
Configuration: Vertical
Latitude: 39.610000
Longitude: -82.860000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-07-01 Proposed Formations:CLINTON/KNOX, Issued Date:7/1/2010, Expired Date:7/1/2011 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Plugged/Abandoned 2011-04-21
Reached Total Depth 2011-04-21
Construction Permit Expires 2011-07-01
Completion Report Received 2011-08-30
Record Last Modified 2013-03-14

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0919829267 2011-04-18 Drill / Deepen / Reopen No Violations - contacted for surface casing. On site Bowman Drilling contactor doing drilling. Spud 4/15/2011 conductor casing set 5/15/2011 to a depth of 168 ft.
8.75 hole drilled to 1285 First joint of 7 casing new the rest of the 7 casing is used witness casing placed into bore hole. Total length of 7 casing 1,278 with landing joint. Copied and total casing tallie. 

Formation Cementing Inc. pump 185 sacks class A cement with 2% gel, cotton seed hulls and flakes added. Wiper plug was use. Cement circulated to surface. - Request for notification for BOP test since several resident in the area. - Rig driller call for BOP test and told him that test couldnt be done until 8 hours after surface casing cementing job is completed. - Back on site for BOP test, took 4 attempts for BOP to pass.

0985778973 2012-02-02 Final Restoration No Violations - Pits have been fill in, area graded to original contour. Landowner has planted winter wheat and is growing. Will approve final restoration.
1629080587 2011-04-21 Drill / Deepen / Reopen No Violations - contacted that the well will be plug.

- Formation Cementing Inc. on site for plugging. - Total depth of well 3,119 feet, 102 joint of drill pipe place into well for plugging. - 300 foot plug set at bottom of well Rose Run formation, pull 15 joints of pipe for next plug, set 200 foot plug for the Trenton formation. Gel spacer place between next plug, pull 44 joints of pipe set 200 foot plug at the bottom of surface casing. Pull 39 joints of pipe for plug below ground level. Pull 4 joints of pipe and top off well after cement settled. - 146 sacks of cement with 2% gel and cotton seed hull were used. 130 Lbs of gel and 100 lbs of accelerator used.

919829267 2011-4-18 0:00: DD No Violations
985778973 2012-2-2 0:00:0 FR No Violations

For data sources see[3]