X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-24422

Well Details

Well ID: 34-121-24422
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Olive Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: ROHRBAUGH-CONNELL
License Status: Producing
License Date: 2013-06-05
Spud Date: 2013-07-31
Spud Drilling Contractor: DAVIS DRLG
Final Drill Date: 2013-10-03
Well Total Depth: 2235.00 ft
Configuration: Vertical
Latitude: 39.730000
Longitude: -81.540000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-06-05 Proposed Formations:BEREA/DEVONIAN SHALE, Issued Date:6/5/2013, Expired Date:6/5/2015 12:00:00 PM, Drilling unit acres:23.463, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2013-10-03
Completion Report Received 2014-02-04
Construction Permit Expires 2015-06-05
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-08-28 H2O 15 391702 Gal 225000 Producers Service Corporation

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 NORTHWOOD ENERGY CORP 174.00 0.00 42
2014 NORTHWOOD ENERGY CORP 852.00 49.00 365
2015 NORTHWOOD ENERGY CORP 279.00 0.00 365
2016 NORTHWOOD ENERGY CORP 149.00 59.00 365
2017 NORTHWOOD ENERGY CORP 120.00 0.00 365
2018 NORTHWOOD ENERGY CORP 50.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 NORTHWOOD ENERGY CORP Brine 200 42
2014 NORTHWOOD ENERGY CORP Brine 1207 365
2015 NORTHWOOD ENERGY CORP Brine 92 365
2016 NORTHWOOD ENERGY CORP Brine 18 365
2017 NORTHWOOD ENERGY CORP Brine 51 365
2018 NORTHWOOD ENERGY CORP Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1572862382 2015-9-24 0:00: PW No Violations 1.00
-535190672 2013-8-1 0:00:0 CS No Violations 3.50
0266232944 2016-05-09 Production Wells No Violations My inspection today finds the well is equipped with a pumping unit. The tank battery consists of one 210 barrel tank, one 100 barrel tank, a separator and a meter with a current chart. The production equipment is set in an earthen dike.
0535190672 2013-08-01 Casing String Witnessed No Violations I am onsite to witness FMS drilling run 88 of 9.625 casing. Formation circulated 75 sks of class A cement into place. The cement stayed at surface.
1136967565 2013-07-31 Drill / Deepen / Reopen No Violations My inspection today finds that the drilling contractor has set the rat hole and the mouse hole properly. They began drilling the 15 conductor hole at 1:00 pm. Fire extinguishers are in place.
1269317599 2017-11-21 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with 8.625 inch diameter surface casing with a casing head, 4.5 inch diameter production casing with a tubing head, 2.375 inch diameter tubing, rods, and a pumping unit powered by natural gas. Production valves were in the open position. The production equipment consisted of one 210 barrel tank, one 100 barrel tank, one drip, and one horizontal separator. A sales meter with a 2 inch sales line, .125 inch orifice plate, and chart recorder with current chart were located by the separator. All equipment was within an earthen dike. The identification was located on the 210 barrel tank and the production records were current.
1457911788 2020-1-6 0:00:0 PW No Violations 0.50
1572862382 2015-09-24 Production Wells No Violations I am accompanied today by Inspector Sefcik, our inspection finds the well is equipped with a pumping unit. The tank battery is comprised of one 210 barrel tank, one 100 barrel tank, a horizontal separator and a meter. All production equipment is located in an earthen dike.
1921041511 2014-07-29 Preliminary Restoration No Violations My inspection today finds the well site meets the preliminary restoration requirements. The well is equipped to be produced with a pumping unit. The tank battery consists of one 210 barrel tank, one 100 barrel tank, a separator, and a meter set inside of a dike. The identification is properly posted.
266232944 2016-5-9 0:00:0 PW No Violations 1.00
682872860 2020-8-12 0:00: PW No Violations 0.40

For data sources see[8]

References