34-121-24355

Well Details

Well ID: 34-121-24355
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Center Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: WATSON S
License Status: Producing
License Date: 2012-03-02
Spud Date: 2012-03-27
Spud Drilling Contractor: FMS DRILLING
Final Drill Date: 2012-04-06
Well Total Depth: 4360.00 ft
Configuration: Vertical
Latitude: 39.800000
Longitude: -81.480000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-03-02 Proposed Formations:BEREA THRU ORISKANY, Issued Date:3/2/2012, Expired Date:3/2/2014 12:00:00 PM, Drilling unit acres:286.673, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2012-04-06
Completion Report Received 2013-03-01
Construction Permit Expires 2014-03-02
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2013-03-04 2130 3152 152
2130 3152 152
2130 3152 152

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-04-18 H2O 7 252140 Gal 60000 Producers Service Corporation 1st stage frac-well was perferated from 2668' to 3152' using hollow steel carrier's with a total of 84 shots in this zone , also set 2nd stage wireline frac plug @2610' and perferate 2nd stage on this date ,2nd stage to be fracked tomorrow.Invoice #13895
2012-04-19 H2O 7 252139 Gal 60000 Producers Service Corporation Perfed from 2130' to 2478' 68 shot- hollow steel carrier .Invoice #13869

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 NORTHWOOD ENERGY CORP 0.00 224.00 366
2013 NORTHWOOD ENERGY CORP 13257.00 5800.00 365
2014 NORTHWOOD ENERGY CORP 10727.00 4290.00 365
2015 NORTHWOOD ENERGY CORP 5398.00 1998.00 365
2016 NORTHWOOD ENERGY CORP 4529.00 716.00 365
2017 NORTHWOOD ENERGY CORP 4251.00 390.00 365
2018 NORTHWOOD ENERGY CORP 3560.00 328.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 NORTHWOOD ENERGY CORP Brine 521 366
2013 NORTHWOOD ENERGY CORP Brine 941 365
2014 NORTHWOOD ENERGY CORP Brine 25 365
2015 NORTHWOOD ENERGY CORP Brine 22 365
2016 NORTHWOOD ENERGY CORP Brine 34 365
2017 NORTHWOOD ENERGY CORP Brine 48 365
2018 NORTHWOOD ENERGY CORP Brine 119 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-105222550 2013-2-14 0:00: PW No Violations 6.00
-1936224599 2018-11-8 0:00: PW No Violations 1.00
-196480471 2015-11-9 0:00: PW No Violations
-362316994 2020-3-4 0:00:0 PW No Violations 0.50
-533200533 2015-11-13 0:00 PW No Violations 1.00
-599234449 2019-4-12 0:00: PW No Violations 1.50
-709431626 2020-3-3 0:00:0 PW No Violations 0.50
0105222550 2013-02-14 Production Wells No Violations My inspection today finds that the pressure relief valve has been opening and has released approximately 2 bbl of oil. I contacted Northwood Energy and Corps Oil Field Services and told them of the spill. Within two hours there were five contractors on site to clean the spill. By 3:00pm. the spill had been cleaned.
0160763153 2019-04-23 Production Wells No Violations The purpose of my inspection is to follow up on a previously issued compliance notice. On the day of my inspection I witnessed production equipment including a 210 barrel steel production fluid storage tank, 100-barrel steel production fluid storage tank, a horizontal separator which appears to be the primary means of separation and a vertical separator that is acting as a fluid drop out for the sales line, there is also a drip and 2-inch diameter meter run with .500 orifice. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing with 2.375-inch diameter tubing, with rods, a lubricator, and a Churchill Pumping Unit with an electric motor. The lubricator on the well head was running into a 50-gallon steel drum. At the time of my inspection it appeared that the contaminated soil had been removed from around the well head, the earthen containment was still in place but appeared to be free of pollution and contamination. At the time of my inspection Mike Corp a contractor for Northwood Energy Corporation stopped by, I informed Mike that the trash and jugs around the pumping unit needed to be cleaned up, but compliance issued for pollution and contamination will be closed.
0196480471 2015-11-09 Production Wells Violations Noted My inspection today finds an area of crude oil contamination 45 from the wellhead. An area approximately 40 square feet is discolored and has a strong odor of crude oil. A small earthen dike around the wellhead has a couple inches of oil contaminated absorbent lying in it. The tank battery has multiple leaking pipe connections with some of them allowing natural gas to escape to atmosphere and oil to reach the ground. Remove all contaminated soil and repair
0451175211 2019-01-23 Production Wells No Violations The purpose of my inspection is to follow up on a previously issued compliance notice. On the day of my inspection I witnessed production equipment including a 210 barrel, and 100-barrel steel production fluid storage tank, a horizontal separator which appears to be the primary means of separation and a vertical separator that is acting as a fluid drop out for the sales line, there is also a drip and 2-inch diameter meter run with .500 orifice. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing with 2.375-
0452842061 2013-02-14 Production Wells No Violations Notification was received at 7:35 Am by Eric Byers of Byers Oil & Gas that He observed the well storage tank battery separator dispersing fluid. I made notification to the lead inspector Eric Conrad and proceeded to respond to the site. Upon arrival @ 7:40 Am it was observed that the separator check valve was releasing oil into the tank battery. At 7:45 Am a Northwood representative arrived and shut the well in stopping the dispersant of product. I assisted Inspector Conrad with the spill report and left location at 9:00 Am. Notification was made to the Southeast supervisor Rocky King at 7:38 Am and a copy of the spill report sent Kyle Tharp and Rocky King.
0533200533 2015-11-13 Production Wells No Violations My inspection today finds the previous violation has been resolved.
0599234449 2019-04-12 Production Wells No Violations The purpose of my inspection is to follow up on a previously issued compliance notice. On the day of my inspection I witnessed production equipment including a 210 barrel steel production fluid storage tank, 100-barrel steel production fluid storage tank, a horizontal separator which appears to be the primary means of separation and a vertical separator that is acting as a fluid drop out for the sales line, there is also a drip and 2-inch diameter meter run with .500 orifice. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing with 2.375-inch diameter tubing, with rods, a lubricator, and a Churchill Pumping Unit with an electric motor. There was approximately 80 square feet of pollution and contamination in a dike that was created around the well head. There were multiple areas on the well equipment that appeared to be leaking, and the lubricator valve was open and running to a 50-
1100097963 2012-09-11 Production Wells No Violations My inspection today finds the well is equipped with 4.5 casing, 2.375 tubing, rods, and a pump jack. The tank battery consists of one 210 bbl tank, one 100 bbl tank, a separator, and a meter inside of a dike with proper identification. The location has recently been seeded. Pipe line work is under way.
1329462201 2018-12-03 Production Wells Violations Noted On the day of my inspection I witnessed production equipment including a 210 barrel, and 100 barrel steel production fluid storage tank, a horizontal separator which appears to be the primary means of separation and a vertical separator that is acting as a fluid drop out for the sales line, there is also a drip and 2 inch diameter meter run with .500 orifice. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing with 2.375-inch diameter tubing, with rods, a lubricator, and a Churchill Pumping Unit with an electric motor. There was approximately 80 square feet of pollution and contamination in a dike that was created around the well head. There were multiple areas on the well equipment that appeared to be leaking. All valves were open at the time of my inspection and the well was pumping at the time of my inspection, production was reported for 2017. I contacted Northwood Energy Corporation, Cory McCudden and informed him a compliance notice will be issued for the well.
1361304879 2013-02-19 Production Wells No Violations My inspection today finds the small oil spill has been fully cleaned and there is no oil visible in the effected area.
1404240197 2014-07-01 Production Wells No Violations My inspection finds Corps Well Service is cleaning a small oil spill around the well. A small dike around the wellhead contained the oil in 4 x 4 area. The company has removed all heavy oil from the area and is applying a bio remediating material.
1558713196 2019-5-24 0:00: WR No Violations 1.00
160763153 2019-4-23 0:00: PW No Violations 1.00
1765266350 2019-11-1 0:00: PW No Violations 0.80
1780753188 2012-10-25 Preliminary Restoration No Violations My inspection today finds the well site has been reclaimed. The pits are filled, and vegetation has been established.
1936224599 2018-11-08 Production Wells No Violations On the day of my inspection I witnessed production equipment including a 210 barrel, and 100 barrel steel production fluid storage tank, a horizontal separator which appears to be the primary means of separation and a vertical separator that is acting as a fluid drop out for the sales line, there is also a drip and 2 inch diameter meter run with .500 orifice. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing with 2.375-inch diameter tubing, with rods and a Churchill Pumping Unit with an electric motor. There was approximately 80 square feet of pollution and contamination in a dike that was created around the well. There were multiple areas on the well equipment that appeared to be leaking. I contacted Mike Corp with Northwood energy and informed him of the problem. Identification tags were present, and production was reported for 2017.
451175211 2019-1-23 0:00: PW No Violations 1.00
452842061 2013-2-14 0:00: PW No Violations
97722671 2019-9-11 0:00: PW No Violations 0.80

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0196480471 US-OH-119841 2015-11-23 Well operation causing pollution and contamination
1329462201 US-OH-109430 2019-05-13 9-1-07 Well operation causing pollution and contamination

For data sources see[9]