If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-24100 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.78,"lon":-81.51,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Noble Township | |
Operator Name: NORTHWOOD ENERGY CORP | |
Well Pad ID: | |
Farm/Lease Name: STATE-MINYO UNIT | |
License Status: Producing | |
License Date: 2004-08-04 | |
Spud Date: 2004-10-11 | |
Spud Drilling Contractor: FMS DRILLING | |
Final Drill Date: 2004-10-21 | |
Well Total Depth: 5774.00 ft | |
Configuration: Vertical | |
Latitude: 39.780000 | |
Longitude: -81.510000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2004-08-04 | Proposed Formations:CLINTON-MEDINA, Issued Date:8/4/2004, Expired Date:8/4/2005 6:00:00 AM, Drilling unit acres:58, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2004-10-11 | RBDMS Rec |
Completed | 2004-10-21 | RBDMS Rec |
Reached Total Depth | 2004-10-21 | RBDMS Rec |
Completion Report Received | 2005-03-21 | RBDMS Rec |
Construction Permit Expires | 2005-08-04 | RBDMS Rec |
Change of Owner | 2014-11-05 | Operator changed from 2680, ENERGY CONTRACTORS INC to 1634, NORTHWOOD ENERGY CORP |
Record Last Modified | 2014-11-05 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2005-06-01 | 5495 | 5533 | 32 |
5495 | 5533 | 32 | |
5495 | 5533 | 32 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1605 Bbl | 17500 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | ENERGY CONTRACTORS INC | 858.00 | 0.00 | 180 |
2006 | ENERGY CONTRACTORS INC | 1608.00 | 0.00 | 365 |
2007 | ENERGY CONTRACTORS INC | 580.00 | 0.00 | 300 |
2010 | ENERGY CONTRACTORS INC | 1292.00 | 0.00 | 365 |
2011 | ENERGY CONTRACTORS INC | 1238.00 | 0.00 | 365 |
2012 | ENERGY CONTRACTORS INC | 864.00 | 0.00 | 366 |
2013 | ENERGY CONTRACTORS INC | 1190.00 | 0.00 | 270 |
2014 | NORTHWOOD ENERGY CORP | 1278.00 | 0.00 | 365 |
2015 | NORTHWOOD ENERGY CORP | 1254.00 | 0.00 | 365 |
2016 | NORTHWOOD ENERGY CORP | 337.00 | 0.00 | 365 |
2017 | NORTHWOOD ENERGY CORP | 671.00 | 0.00 | 365 |
2018 | NORTHWOOD ENERGY CORP | 742.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | ENERGY CONTRACTORS INC | Brine | 485 | 180 |
2006 | ENERGY CONTRACTORS INC | Brine | 160 | 365 |
2007 | ENERGY CONTRACTORS INC | Brine | 280 | 300 |
2010 | ENERGY CONTRACTORS INC | Brine | 308 | 365 |
2011 | ENERGY CONTRACTORS INC | Brine | 141 | 365 |
2012 | ENERGY CONTRACTORS INC | Brine | 0 | 366 |
2013 | ENERGY CONTRACTORS INC | Brine | 0 | 270 |
2014 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2015 | NORTHWOOD ENERGY CORP | Brine | 90 | 365 |
2016 | NORTHWOOD ENERGY CORP | Brine | 301 | 365 |
2017 | NORTHWOOD ENERGY CORP | Brine | 34 | 365 |
2018 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1403028133 | 2020-6-4 0:00:0 | PL | No Violations | 0.50 |
-1624064117 | 2016-11-23 0:00 | PW | No Violations | 1.00 |
-184172773 | 2017-7-10 0:00: | PW | No Violations | 2.00 |
-825898092 | 2019-1-4 0:00:0 | PW | No Violations | 0.80 |
0184172773 | 2017-07-10 | Production Wells | No Violations | The purpose of my inspection was a follow up on a compliance notice numbered 1477077738. The compliance notice stated that the well was in violation of 1501:9-9-05(A)(1) Well insufficiently equipped to prevent escape of oil and gas, 1501:9-9-05(A)(10) Failure to legibly identify, and 1501:9-9-05(A)(2) Violation of tank spacing requirements. During my inspection the well was equipped with a 4.5 inch diameter production casing with a casing head, 2 .875 inch diameter intermediate casing with a tubing head, and 1.5 inch diameter tubing with 2 inch diameter production lines attached. Production valves were in the open position. The production equipment consisted of one 210 barrel tank and one 1550 gallon poly tank. Identification was located on the 1550 gallon poly tank. No leaks were observed from the wellhead, the 1550 gallon poly tank had been moved to meet setback requirements, and the identification was located on the 1550 gallon poly tank. All violations from the compliance notice have been resolved. |
0386005201 | 2012-05-07 | Production Wells | No Violations | Inspection of the well head found 8.625 surface casing -4.5 production casing with the production valves and the well selling gas off the 4.5 casing. |
0461915014 | 2004-10-12 | Drill / Deepen / Reopen | No Violations | Stopped by rig for update track hoe on site digging air pit so operator can commence drilling. |
0825898092 | 2019-01-04 | Production Wells | No Violations | On the day of my inspection I witnessed the well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing, and 1.5-inch diameter tubing, that appeared to be open flowing, there appeared to be a domestic gas hookup attached to the well head, but the valve was closed at the time of my inspection. There was a 37-barrel plastic production fluid storage tank, and a 210-steel production fluid storage tank that were near the well head and no longer in use. Production equipment included a 100-barrel steel production fluid storage tank, horizontal separator, 2-inch diameter meter run, with drip all contained within an earthen dike. The production equipment was located off township road 128 at State Farm Road, near Caldwell lake. At the time of my inspection all production valves were closed and well appeared to be idle, identification was present on the production equipment, and production was reported for 2017. |
1097490745 | 2004-10-08 | Drill / Deepen / Reopen | No Violations | Meeting with drilling contractor(FMS-Omar Fracks) to discuss location of well suggested to contractor that he take all due precautions at site well location is located next to 2 small streams that feed water to Caldwell Lake which is where villiage recieves their water supply,requested reenforced pit liner and minimun of 60 of conductor left in hole. |
1098631521 | 2004-10-18 | Drill / Deepen / Reopen | No Violations | Stopped by drilling rig for update they were drlling ahead at 3719 dusting in Ohio Shale should top big lime around 3850+-. |
1099130903 | 2004-10-25 | Drill / Deepen / Reopen | No Violations | Stopped by location to check on drilling rig ,they T.D. ed well over the weekend 4.5 casing runto 5700 according to company rep Jerry Phifer had good gas show in Clinton sand. |
1117925336 | 2005-06-01 | Preliminary Restoration | No Violations | Restoration work not completed ,service rig still on site. pit has been filled in and gas line to tank site laid, contacted well owner Jerry Phiefer and suggested that he get restoration completed.
Well is located on State Research Farm in Belle Valley. |
1335443468 | 2012-04-26 | Production Wells | No Violations | Status check on well -inspection found 4.5 casing with flow line hooked up and valve open -No well Id present -old 210 barrel tank sitting out in field by well not hooked up and swab rig has been sitting over hole for 6 months. |
1477077738 | 2016-10-21 | Production Wells | Violations Noted | On the inspection today I was accompanied by Supervisor Eric Conrad. Eric received an anonymous complainant about an H2S leak on this well (complaint #5458). We arrived on location and could hear that gas was leaking from the wellhead. After closer inspection we found that neither of our gas detection meters could read any H2S and, no H2S could be smelled in the area. The well is equipped with a 4 1/2 inch diameter wellhead, 2 7/8 inch diameter intermediate casing, 1 1/2 inch diameter production tubing, and 2 inch diameter steel production lines. This well is located close to two water ways and a road. Two valves on the wellhead have no plugs in them. The well had a 1600 gallon plastic tank about 10 feet from the well head and there was a 210 barrel steel tank about 150-200 feet away from the well head. The plastic tank does not meet the set back requirements from tank spacing according to OAC 1501:9-9-05(A)(2) this tank must be 50 feet away from the well head. The tanks had no sign of proper ID on them and require ID. The company must post proper identification in accordance with 1501:9-9-05(A)(10). The well must be repaired to prevent the escape of gas, plugs put on all valves, and proper identification posted within 15 days of this compliance being issues. |
1624064117 | 2016-11-23 | Production Wells | No Violations | The purpose of my inspection today is a follow up on a compliance notice. During my inspection the well was
equipped with a 4.5 inch diameter production casing, 2 .875 inch diameter intermediate casing, 1.5 inch diameter tubing, and 2 inch diameter steel production lines. The well was not leaking and plugs have been placed in the valves. Well insufficiently equipped to prevent escape of oil and gas violation is now satisfied. The production equipment consists of one 210 barrel tank and one 1600 gallon poly tank. There was not any identification located on the tanks or the wellhead. Identification must be posted to bring the well back into compliance. |
386005201 | 2012-5-7 0:00:0 | PW | No Violations | |
461915014 | 2004-10-12 0:00 | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1477077738 | US-OH-113648 | 2016-12-02 | 9-9-05(A)1 | Well insufficiently equipped to prevent escape of oil and gas |
1477077738 | US-OH-113649 | 2016-12-02 | 9-9-05(A)10 | Failure to legibly identify well |
1477077738 | US-OH-113650 | 2016-12-02 | 9-9-05(A)2 | Violation of tank spacing requirements |
For data sources see[9]