If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-23690 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.83,"lon":-81.67,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Brookfield Township | |
Operator Name: D & D ENERGY COMPANY | |
Well Pad ID: | |
Farm/Lease Name: PAISLEY-WYNNE | |
License Status: Producing | |
License Date: 2014-05-02 | |
Spud Date: 1989-09-22 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1989-09-26 | |
Well Total Depth: 5350.00 ft | |
Configuration: Vertical | |
Latitude: 39.830000 | |
Longitude: -81.670000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1989-08-30 | 182 BELDEN & BLAKE CO GeoDate 8/30/89 |
Oil and Gas | 1989-08-30 | Issued Date 8/30/89 Expired Date 8/30/90 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05350 Proposed Drill Depth 05350 |
Original Spud | 1989-09-21 | PR status based on E. Conrad inspection, ALE 3/2/16 |
Completed | 1989-09-26 | PR status based on E. Conrad inspection, ALE 3/2/16 |
Reached Total Depth | 1989-09-26 | PR status based on E. Conrad inspection, ALE 3/2/16 |
Completion Report Received | 1989-10-19 | PR status based on E. Conrad inspection, ALE 3/2/16 |
CO | 1997-01-28 | 1217 HARRISON ENERGY GeoDate 8/30/89 |
Change of Owner | 2004-01-27 | Operator changed from 1217, HARRISON ENERGY to 5660, S & S ENERGY CORPORATION |
APP | 2014-05-02 | Proposed Formations:, Issued Date:5/2/2014, Expired Date:5/1/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class: |
Change of Owner | 2015-06-02 | Operator changed from 5660, S & S ENERGY CORPORATION to 5569, D & D ENERGY COMPANY |
Construction Permit Expires | 2016-05-01 | PR status based on E. Conrad inspection, ALE 3/2/16 |
Record Last Modified | 2019-06-14 | PR status based on E. Conrad inspection, ALE 3/2/16 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5108 | 5207 | 0 |
5108 | 5207 | 0 | |
2006-09-11 | 5148 | 5206 | 39 |
5148 | 5206 | 39 | |
5108 | 5207 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 132000 Gal | 80000 | FRAC:SAND/WATER |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1990 | BELDEN & BLAKE CORPORATION | 4656.00 | 49.00 | 255 |
1991 | BELDEN & BLAKE CORPORATION | 2258.00 | 93.00 | 365 |
1992 | BELDEN & BLAKE CORPORATION | 1082.00 | 0.00 | 291 |
1993 | BELDEN & BLAKE CORPORATION | 351.00 | 66.00 | 97 |
1996 | BELDEN & BLAKE CORPORATION | 30.00 | 0.00 | 289 |
1997 | BELDEN & BLAKE CORPORATION | 0.00 | 0.00 | 29 |
2003 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2004 | S & S ENERGY CORP | 83.00 | 54.00 | 365 |
2005 | S & S ENERGY CORP | 586.00 | 0.00 | 365 |
2006 | S & S ENERGY CORP | 70.00 | 0.00 | 365 |
2007 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2008 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2009 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2010 | S & S ENERGY CORP | 24.00 | 0.00 | 365 |
2011 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2012 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2013 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2014 | S & S ENERGY CORP | 0.00 | 0.00 | 0 |
2015 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
2016 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
2017 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
2018 | D & D ENERGY COMPANY | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1990 | BELDEN & BLAKE CORPORATION | Brine | 491 | 255 |
1991 | BELDEN & BLAKE CORPORATION | Brine | 226 | 365 |
1992 | BELDEN & BLAKE CORPORATION | Brine | 143 | 291 |
1993 | BELDEN & BLAKE CORPORATION | Brine | 48 | 97 |
1996 | BELDEN & BLAKE CORPORATION | Brine | 0 | 289 |
1997 | BELDEN & BLAKE CORPORATION | Brine | 63 | 29 |
2003 | S & S ENERGY CORP | Brine | 0 | 0 |
2004 | S & S ENERGY CORP | Brine | 21 | 365 |
2005 | S & S ENERGY CORP | Brine | 0 | 365 |
2006 | S & S ENERGY CORP | Brine | 0 | 365 |
2007 | S & S ENERGY CORP | Brine | 0 | 0 |
2008 | S & S ENERGY CORP | Brine | 0 | 0 |
2009 | S & S ENERGY CORP | Brine | 0 | 0 |
2010 | S & S ENERGY CORP | Brine | 0 | 365 |
2011 | S & S ENERGY CORP | Brine | 0 | 0 |
2012 | S & S ENERGY CORP | Brine | 0 | 0 |
2013 | S & S ENERGY CORP | Brine | 0 | 0 |
2014 | S & S ENERGY CORP | Brine | 0 | 0 |
2015 | D & D ENERGY COMPANY | Brine | 0 | 0 |
2016 | D & D ENERGY COMPANY | Brine | 0 | 0 |
2017 | D & D ENERGY COMPANY | Brine | 0 | 0 |
2018 | D & D ENERGY COMPANY | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-478345763 | 2009-1-8 0:00:0 | PW | No Violations | |
-774117982 | 2008-10-21 0:00 | PW | No Violations | |
-822339895 | 2009-10-14 0:00 | PW | No Violations | |
0000PL7277 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0129881106 | 2015-06-05 | Administrative Inspection | No Violations | At 8:56 am. I called and spoke to the owner of S & S Energy. I was informed that as of Monday this week a Form 7 was filled transferring the well to D & D Energy Company. I will contact D & D as soon as the well is transferred. |
0478345763 | 2009-01-08 | Production Wells | Violations Noted | No change in status os well it is still idle&incapable of producing in its present state of repair. |
0507896088 | 2015-11-04 | Production Wells | No Violations | My inspection today finds the well is still incapable of production. The well is shut in at the 4.5 ball valve. The rubber gas line that is attached to the well is nearly broken in two. A horizontal separator is set on location with a meter, but the meter has no chart. The 210 barrel tank is also on location. Cattle have been very active around the well and the production equipment and there is no fence to keep them out. Photos were taken. The well listed in RBDMS as Final Restoration status and it is actually a production well. |
0774117982 | 2008-10-21 | Production Wells | No Violations | FOLLOW UP TO NOV # 1224622893 Upon inspecting well site found well to be idle,last production reported on well was in 2006,all valves at wellhead were shut on the day of my inspection,no production chart in meter box(recorder missing) well is equipped with 11 conductor and 8 surface pipe&4.5 production casing and it appeared that flowlines from well have been disconnected and storage tank if placed back into production will need proper dike construction. |
0822339895 | 2009-10-14 | Production Wells | Violations Noted | Inspection revealed that well is still idle there is not meter at wellsite and all valves at well are still shut,tried to contact well owner via phone call and left message for call back still waiting on return call. |
1115257208 | 2019-04-04 | Production Wells | No Violations | The purpose of my inspection was to follow up on a previously issued compliance notice. On the day of my inspection I witnessed 12-inch diameter conductor, 8.625-inch diameter surface casing, 4.5-inch diameter production casing with a 4.5-inch diameter ball valve that was closed, there was a 4.5 to 2-inch diameter swage nipple, a 2-inch diameter Tee and a motor valve. All production lines had been disconnected from the well and all valves were closed. Production equipment included a 210-barrel steel production fluid storage tank, horizontal separator, and 2-inch diameter meter run with chart recorder, there was no chart in the chart recorder at the time of my inspection. Identification was located on the production fluid storage tank, and production has been reported as 0 since 2011. |
1224622893 | 2008-10-21 | Production Wells | Violations Noted | Upon inspecting well site found well to be idle,last production reported on well was in 2006,all valves at wellhead were shut on the day of my inspection,no production chart in meter box(recorder missing) well is equipped with 11 conductor and 8 surface pipe&4.5 production casing and it appeared that flowlines from well have been disconnected and storage tank if placed back into production will need proper dike construction. |
129881106 | 2015-6-5 0:00:0 | AM | No Violations | 0.50 |
1397074423 | 2014-04-09 | Production Wells | No Violations | Inspected site along with Eric Conrad and it was determined that well is shut in at present time and it was noted that there was no production chart in meter box and all valves at wellhead were closed on this day of our inspection. |
1546202742 | 2013-12-19 | Production Wells | No Violations | COMPLIANCE NOTICE FOLLOW UP. I am unable to find the well. Inspector Ball is going to assist me at another time. |
2001881705 | 2014-04-09 | Production Wells | No Violations | I am accompanied by inspector Dave Ball. My inspection finds the well is equipped with 4.5 casing. The casing has a ball valve on it that is shut. The tank battery is comprised of one 210 bbl tank and a production unit with a meter. The meter does not have a chart on it. I left a message at the phone number listed on RBDMS. The well status needs to be changed. |
2009235829 | 2018-03-19 | Production Wells | No Violations | The purpose of my inspection was a follow up inspection on compliance notice numbered 1224622893. The compliance notice stated the well was idle and it shall be plugged. The well was equipped with 8.625 inch diameter surface casing with a casing head, 4.5 inch diameter production casing, and a 4.5 inch to a 2 inch diameter swage nipple. The production casing valve was in the closed position with no production lines attached. The production equipment consisted of one 210 barrel tank, one horizontal separator, and one sales meter. The sales meter had a 2 inch diameter line, orifice plate, and a chart recorder with no chart present. D&D Energy has submitted production reports since they acquired the well in the year 2015 until 2017 and all zeros have been reported. I will continue to keep in contact with D&D Energy to get the violation resolved. |
507896088 | 2015-11-4 0:00: | PW | No Violations | 2.00 |
iDIAN00617 | 2001-07-24 | Final Restoration | No Violations | |
iDIAN006171 | 2001-7-24 0:00: | FR | No Violations | |
PL7277 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0478345763 | US-OH-125203 | 2008-10-21 | Well shall be plugged | |
0822339895 | US-OH-129374 | 2008-10-21 | Well shall be plugged | |
1224622893 | US-OH-106048 | 2008-10-21 | Well shall be plugged |
For data sources see[9]