X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-22459

Well Details

Well ID: 34-121-22459
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Sharon Township
Operator Name: BUCKSHOT DISPOSAL LLC
Well Pad ID:
Farm/Lease Name: DUDLEY H
License Status: Active Injection
License Date: 1985-01-29
Spud Date: 1985-02-28
Spud Drilling Contractor: J & B DRILLING
Final Drill Date: 1985-02-28
Well Total Depth: 5769.00 ft
Configuration: Vertical
Latitude: 39.740000
Longitude: -81.590000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-11-24 6 BENATTY CORP GeoDate 11/24/80
Oil and Gas 1980-11-24 Issued Date 11/24/80 Expired Date Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1981-03-01 CHG IN TYPE WELL/CLASS 2-2-85
CO 1985-01-29 1694 MATT WELL SERVICE INC GeoDate 1/29/85
Conversion to Injector 1985-01-29
Salt Water Injection Well 1985-01-29 Issued Date 1/29/85 Expired Date 7/28/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05769 Proposed Drill Depth 05769
Storage Well 1985-01-29 Issued Date 1/29/85 Expired Date 7/28/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05769 Proposed Drill Depth 05769
Completed 1985-02-28 CHG IN TYPE WELL/CLASS 2-2-85
Reached Total Depth 1985-02-28 CHG IN TYPE WELL/CLASS 2-2-85
Completion Report Received 1985-03-13 CHG IN TYPE WELL/CLASS 2-2-85
First Injection 1985-04-29 CHG IN TYPE WELL/CLASS 2-2-85
Construction Permit Expires 1985-07-28 CHG IN TYPE WELL/CLASS 2-2-85
CO 1991-09-16 2111 BUFFALO OILFIELD SER INC GeoDate 1/29/85
Annulus Pressure Monitoring Approved 1991-10-15 CHG IN TYPE WELL/CLASS 2-2-85
CO 1994-09-30 4930 CANTON OIL & GAS COMPANY GeoDate 1/29/85
Change of Owner 2004-07-14 Operator changed from 4930, CANTON OIL & GAS COMPANY to 7666, ARVILLA OILFIELD SERVICES LLC
Change of Owner 2011-03-18 Operator changed from 7666, ARVILLA OILFIELD SERVICES LLC to 8690, SES ASSETS LLC
Last Compliance Report 2011-12-05 CHG IN TYPE WELL/CLASS 2-2-85
Change of Owner 2018-07-24 Operator changed from 8690, SELECT ENERGY SERVICES LLC to 10176, BUCKSHOT DISPOSAL LLC
Record Last Modified 2018-07-24 CHG IN TYPE WELL/CLASS 2-2-85

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2015-05-11 5512 5572 401
5512 5572 401
5512 5572 401

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
FOAM 0 70000 Gal 50000 FRAC: H2O, 40/20 SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BENATTY CORP 971.00 0.00 0
1985 BENATTY CORP 334.00 28.00 0
1987 BENATTY CORP 0.00 0.00 365
2000 TRIAD RESOURCES INC 0.00 0.00 365
2001 TRIAD RESOURCES INC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BENATTY CORP Brine 0 0
1985 BENATTY CORP Brine 0 0
1987 BENATTY CORP Brine 0 365
2000 TRIAD RESOURCES INC Brine 0 365
2001 TRIAD RESOURCES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1034570819 2003-9-24 0:00: SW No Violations
-1061239667 2018-7-11 0:00: SW No Violations
-1070488336 2003-1-14 0:00: SW No Violations
-1082796874 2010-5-24 0:00: SW No Violations
-1089828038 2017-11-16 0:00 SW No Violations
-1128526579 2019-10-8 0:00: SW No Violations
-1176174140 2007-11-2 0:00: SW No Violations
-1202047988 2018-6-6 0:00:0 SW No Violations
-1208027844 2011-2-22 0:00: SW No Violations
-1214359037 2014-3-7 0:00:0 SW No Violations
-1232395679 2013-7-12 0:00: SW No Violations
-1234398277 2014-1-24 0:00: SW No Violations
-1248848273 2017-11-17 0:00 SW No Violations
-1265103002 2006-3-8 0:00:0 SW No Violations
-1278295446 2014-12-10 0:00 SW No Violations
-1319742008 2014-10-20 0:00 SW No Violations
-1370184678 2019-4-4 0:00:0 SW No Violations
-1376452018 2016-2-3 0:00:0 SW No Violations
-1420254080 2011-11-28 0:00 SW No Violations
-1427278352 2014-9-29 0:00: SW No Violations
-1449701739 2009-3-4 0:00:0 SW No Violations
-147191144 2003-6-2 0:00:0 SW No Violations
-1509397466 2016-11-25 0:00 SW No Violations
-1551634801 2016-6-24 0:00: SW No Violations
-159478061 2010-9-18 0:00: SW No Violations 2.50
-1599496664 2018-8-20 0:00: SW No Violations
-1622268370 2010-11-3 0:00: SW No Violations
-1666888435 2007-5-3 0:00:0 SW No Violations
-1674113462 2015-5-15 0:00: SW No Violations
-1695921836 2010-10-12 0:00 SW No Violations
-1708578572 2020-7-31 0:00: SW No Violations
-1726371919 2017-5-11 0:00: SW No Violations
-1737486473 2004-10-26 0:00 SW No Violations
-1739244398 2006-3-30 0:00: SW No Violations
-1756566168 2018-4-11 0:00: SW No Violations
-1758763216 2016-7-20 0:00: SW No Violations
-1764580609 2014-8-4 0:00:0 SW No Violations
-1807049475 2014-4-9 0:00:0 SW No Violations
-1852559050 2011-11-4 0:00: SW No Violations
-1873571899 2016-3-29 0:00: SW No Violations
-1914697768 2013-7-31 0:00: SW No Violations
-1958967452 2007-10-3 0:00: SW No Violations
-2023885446 2019-2-24 0:00: SW No Violations
-2030390827 2008-4-2 0:00:0 SW No Violations
-205905944 2003-5-12 0:00: SW No Violations
-2084342681 2020-6-1 0:00:0 SW No Violations
-2100716416 2017-3-14 0:00: SW No Violations
-210785966 2008-2-12 0:00: SW No Violations
-2109517176 2018-2-16 0:00: SW No Violations
-2117273239 2015-3-11 0:00: SW No Violations
-2122935242 2017-11-14 0:00 SW No Violations
-2127081626 2010-7-16 0:00: SW No Violations
-2127348316 2012-3-20 0:00: SW No Violations
-2136285378 2015-8-20 0:00: SW No Violations
-2143174135 2011-11-18 0:00 SW No Violations
-225795701 2011-3-22 0:00: SW No Violations
-233596896 2017-11-20 0:00 SW No Violations
-26371525 2004-11-9 0:00: SW No Violations
-322341234 2018-4-6 0:00:0 SW No Violations
-338051845 2017-2-10 0:00: SW No Violations
-371177029 2009-9-25 0:00: SW No Violations
-385641116 2003-8-4 0:00:0 SW No Violations
-425342384 2007-4-2 0:00:0 SW No Violations
-4349556 2008-3-3 0:00:0 SW No Violations
-452210633 2019-3-21 0:00: SW No Violations
-541437671 2020-3-5 0:00:0 SW No Violations
-548810630 2008-10-2 0:00: SW No Violations
-609636938 2011-5-19 0:00: SW No Violations
-613364163 2017-4-28 0:00: SW No Violations
-616682008 2006-1-3 0:00:0 SW No Violations
-631117840 2018-1-12 0:00: SW No Violations
-651013293 2011-1-26 0:00: SW No Violations
-685563879 2019-11-5 0:00: SW No Violations
-706700521 2009-8-11 0:00: SW No Violations
-718961178 2004-4-5 0:00:0 SW No Violations
-738583977 2014-9-4 0:00:0 SW No Violations
-74908104 2015-4-29 0:00: SW No Violations 8.00
-772513129 2014-12-23 0:00 SW No Violations
-789827267 2013-9-9 0:00:0 SW No Violations
-807362365 2006-12-14 0:00 SW No Violations
-812414347 2007-1-2 0:00:0 SW No Violations
-824361904 2008-6-2 0:00:0 SW No Violations
-848013739 2016-6-16 0:00: SW No Violations
-871419498 2013-10-15 0:00 SW No Violations
-899632589 2006-8-15 0:00: SW No Violations
-977879251 2007-6-5 0:00:0 SW No Violations
-995709441 2015-5-6 0:00:0 SW No Violations
-996432835 2007-3-9 0:00:0 SW No Violations
00001259i9 2002-06-18 Salt Water Injection Well No Violations
0000PL7843 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0000UIC233 1987-06-03 Salt Water Injection Well No Violations 1501:9-3-07(E)(F)
0004349556 2008-03-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was not in operation during my inspection, noted 3 company owned vac trucks unloading at facility during my inspection, also could use some stone around facility to help curb muddy conditions at site.

0019477059 2002-10-30 Salt Water Injection Well No Violations
0026371525 2004-11-09 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

(11)housekeping needed in unloading pad area. Pump not running today.

0038386028 2004-05-10 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(3)housekeeping needed in tank area(suggest steam cleaning area). (11)housekeeping needed in unloading area.

0045060778 2006-11-06 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump not in operation on the day of my inspection,noted that stone could be used around facility! Housekeeping needed below vault area(seed&mulch area).

005604i101 2002-03-19 Salt Water Injection Well No Violations Pulling tubing. Well out of service.
005604i105 2002-03-20 Work Over Reconditioning No Violations Baker Lockser A-3 Packer set at 5420ft. (2ft.)higher than last time on 9/10/2001. 70Bbl .Fresh water with 5Gal .Anhib. Displaced with 20Bbl . Pressured up to 1550Psi. Held pressure for 30min. Test completed at 3:40pm. 1550psi.
0068946847 2018-05-11 Salt Water Injection Well No Violations Inspection today revealed that well is down due to new ownership waiting on wells to be transferred to new owner.
0074908104 2015-04-29 Salt Water Injection Well No Violations On site to set packer and perform MIT test on said well.

Packer is set at 5421 and they flushed annulus of tubing with 60 bbl fresh water and 10 gallon of inhibitor and once test passed they performed a 1500 gallon acid treatment on well.

0082783323 2012-01-04 Salt Water Injection Well No Violations Stopped by well site to check with operator to see when they have wire line truck and Producers Services scheduled to perform work on said well ,well tender stated it would take place tomorrow morning.
0095690557 2008-01-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Pump was not in operation during my inspection,operator needs to apply annulus pressure to backside of tubing contact inspector prior to doing so he needs to be present to witness operation.

0099292915 2016-04-18 Salt Water Injection Well No Violations Received phone call from well operator stating that they noticed a pin hole in flow line going to well instructed them to shut down injection operations and make arrangements to replace entire flow line from pump house to wellhead and they agreed to replace line and once in place we will pressure test line before placing well back into operation.
0114270476 2017-06-06 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and it ws noted that site has been recently weedeated.
0133116845 2004-06-07 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

(11)Housekeeping needed in unloading area. Noted:Fresh weedeating done since last inspection,small lead on tank plumbing repaired as time permits more stone needed in tank area.

0147191144 2003-06-02 Salt Water Injection Well No Violations (9)#1cylinder on pump needs repaired

clean in vault area needed remove contaminated soil +replace with fresh soil+then proceed to seed &mulch.

0152054602 2016-02-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one Jayhawk Water Services truck was unloading at the facility today.
0159478061 2010-09-18 Salt Water Injection Well No Violations On site again to monitor Producers Services and Baker Hughes continue testing of Injection Well, arrived on site and monitored pressure while service company applied chemical to injection zone it was determined that company will resume normal operations 9/20/10.
0161550408 2005-04-06 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory this inspection.

Roustabout crew on site to clean out old storage tanks and remove them from site operator is going to replace them with 4 210 tanks,also crew will be replacing all plumbing going to tanks.

0192126893 2005-04-27 Salt Water Injection Well No Violations Stopped by well site to check on welders plumbing up of new lines at facility they stated they would be the better part of next week before completing job at hand,after completing plumbing task they plan on repairing lay down tank and install fresh stone around facility,and install new storage building and place portal- john at facility.
0205905944 2003-05-12 Salt Water Injection Well No Violations No violations noted,facility appears to be in good repair

More clean-up needed in vault area.

0210785966 2008-02-12 Salt Water Injection Well No Violations On site to witness mini test on annulus of tubing,Sweeny Well Service applied 320 psi on backside of tubing,monitored pressure for 15 min. with no decline in pressure Test Passed,they left pressure on backside of tubing.
0224344958 2013-05-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that one Myers truck was unloading at site during my inspection there UIC# was posted on truck#25-427 and dike was free of fluid and vault has been recently cleaned.
0225795701 2011-03-22 Salt Water Injection Well No Violations Inspection revealed that injection pump was not operating during my inspection.

Note I.D. at facility needs to be changed to Select Energy not Arvilla and old tanks at site still need to be removed.

0233596896 2017-11-20 Salt Water Injection Well No Violations No activity at the site today due to first day of deer season in West Virginia,cleanup crew will resume work at the site tomorrow.
0239090865 2011-05-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection in conversation with well operator stating that owner is planning on making improvements at site such as to remove old storage tanks and replace with new ones and possibly construct new pump house.
0244911022 2016-03-16 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection and it was noted that one H&L Water services vacuum truck was unloading at the facility today.
0258854734 2014-05-08 Salt Water Injection Well No Violations Inspection revealed that fluid end on injection pump has been replaced and it was not in operation during my inspection.
0303595548 2011-10-18 Salt Water Injection Well No Violations Inspection revealed that pump was in operation during my inspection and it was noted that injection pressure is nearing maximum level. The storage tank that was to be removed from site is still hooked up and showing signs of seepage on bottom of tank. Stone is needed in area above unloading pad. The unloading pad has large section of concrete eroded from it and it could possibly be a hazard to company truck drivers.
0319587442 2018-07-12 Salt Water Injection Well No Violations Inspection revealed that new office building has been delivered to site and placed on new concrete base.
0322341234 2018-04-06 Salt Water Injection Well No Violations Well is not in operation at this time and well has been sold and new owner wants to meet possibly next week.
0325952525 2011-12-08 Salt Water Injection Well No Violations My inspection revealed that this well is in operation and the pumping unit was in service. The operator is still having storage tanks cleaned and they will remove two tanks from facility after contractor completes cleaning operation.

Note: Once well is back to normal operation, stone is needed around entire facility too help control mud being dragged out onto county road.

0331201986 2003-02-05 Salt Water Injection Well No Violations No violations noted this inspection.

(3)General house keeping in tank area (11) House keeping in unloading pad area. Vault sump pump needs repaired or replaced!

0334564180 2006-10-04 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Noted that weed eating around facility has been recently preformed, area below fault in need of seed&mulch need to establish vegetation too prevent possible erosion.

0338051845 2017-02-10 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and operating at maximum pressure and it was noted that one Evolution tanker was unloading at the facility at the time of my inspection.
0340841955 2018-01-05 Surface Facility Construction No Violations Met with company rep Ken Parsons and discussed resolving the previous compliance notice issued for said well informed him that past violations at the well has been resolved.
0346380656 2015-06-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that two company owned vacuum trucks were unloading at the facility during my inspection.
0371177029 2009-09-25 Salt Water Injection Well No Violations Inspection revealed that well is not in operation today, noted that sump pump from vault was running.

Note: Stone is needed at facility to help cut down on tracking mud and other debris out onto highway.

0385641116 2003-08-04 Salt Water Injection Well No Violations Facility appears to be in good repair,no violations noted.

(3)strongly suggest steam clean tank area and pump area.

0385680464 2011-03-07 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation during my inspection.

Note: Four company owned vac trucks were unloading at site during my inspection also noted that old unused storage tanks still need to be removed from site.

0394508688 2007-07-09 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Note Housekeeping needed below vault area,seed&mulch needs to be applied to affected area!

0397370405 2017-06-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that weedeating has been recently completed at the site.
0411429504 2005-03-14 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactry condition this inspection.

(3)Clean up needed in tank area(steamed cleaned). (7)1/4 valves on wellhead in need of being replaced. (11)Housekeeping needed in unloading area. (12)Restoration work needed in area of old pit.

0422406481 2016-12-21 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that repair worker was on site repairing electric motor on vault sump pump.
0425342384 2007-04-02 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Noted that operator has constructed dike around vault to prevent possible spill in the event of vault running over,housekeeping is needed in tank area.

0434146839 2015-06-01 Salt Water Injection Well No Violations On site to meet with company reps to discuss replacing several of the storage tanks at the facility they are currently showing signs of needing repaired/replaced and they are currently advising corporate office of situation.
0452210633 2019-03-21 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that two Ryan Environmental vacuum trucks were on site offloading during my inspection.
0473330585 2017-11-21 Salt Water Injection Well No Violations On site along with contractor Ken Parsons to witness uncovering of vault it was determined that vault has small amount of leakage noted from the bottom and it was requested that they install new vault once it delivered they will install it a replumb it back up.

Instructed contractor to have old vault to be hauled to a approved landfill for proper disposal.

0499321615 2017-12-22 Salt Water Injection Well Violations Noted Inspection revealed that previous compliance notice issued on 11/13/2017 have resolved,owner has removed all contaminated soils and properly disposed of it and replaced vault and hauled in fresh soils and seeded and mulched affected area.
0539179268 2004-01-09 Salt Water Injection Well No Violations Facility appears to be in satisfactory condition on the day of my inspection.No violations noted.

(3)Housekeeping needed in tank area. (9)Suggest working on #1cylinder on pump(Packing)

0548810630 2008-10-02 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.
0556425115 2014-04-23 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today due to fact that fluid end on injection pump is being rebuilt and they stated that fluid end should be rebuilt and back in service next week.
0578969470 2010-01-19 Salt Water Injection Well No Violations Inspection revealed that injection pump not in operation today, noted two company owned vac trucks unloading at facility during my inspection.

Note: Annulus pressure elevated since my last inspection will monitor well more closely.

0609636938 2011-05-19 Salt Water Injection Well No Violations On site with Tom Tomastik to inspect well site.

Note: Dike wall going to pump house needs to be raised up to level of existing dike surroundings.

0613364163 2017-04-28 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that one Evolution tanker was unloading at the facility during my inspection.
0616682008 2006-01-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump not running during my inspection. Company owned truck unloading at site during my inspection,talked to driver and he stated he would empty vault before leaving site to allow for volume in vault due to fact of recent rainfall.

0631117840 2018-01-12 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and Hawkins Well Service was on site replacing sump pump in vault and caretaker was stating that both Select Energy wells have sold to new owner taking them over in February 2018.
0649291313 2010-04-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Talked to well tender concerning 300 bbl tank at site which is showing signs of seepage requested that company empty fluids from tank and remove tank from site.

0651013293 2011-01-26 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Tank area in need of a good cleaning and also have pressure applied to annulus of tubing. Note: Old storage tanks need to be removed from site and pump house is in need of repair/replacement.

0651183550 2006-06-01 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Note: Weedeating needed around facility,injection pump was in operation on the day of my inspection.

0695229665 2018-11-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one CS Trucking tanker was offloading at the site during my inspection.
0706700521 2009-08-11 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection.

Note: Stone is needed around facility in tank area and also in unloading area noticed several fittings on injection pump showing signs of needing replaced.

0718336792 2013-04-30 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that company had a slick line wire line truck on site to go inside of tubing with tools to determine if they had fill up within casing and it was determined that they had 13 of the injection zone open.
0718961178 2004-04-05 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

(3)tank area needs a good steam cleaning (11)housekeeping needed in unloading area Note:stone is needed around storage tanks.

0738583977 2014-09-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0768362090 2004-12-27 Salt Water Injection Well No Violations On site to witness tubing &packer run in to well,operator ran 172jts. In well =5490 today will run 2 more jets. Tomorrow and pressure test annulus of tubing&packer.

New 2 3/8 tubing J-55 gradeEUE top of cement on backside of 4.5 casing @5070 according to division records.

0772513129 2014-12-23 Salt Water Injection Well No Violations Inspection revealed that owner is making some upgrades to plumbing at the facility and it was noted that one company owned vacuum truck was unloading at the facility during my inspection.

Note: Company rep has sent a request for approval of upgrades being made at this facility.

0774660897 2010-05-03 Salt Water Injection Well No Violations Inspection revealed that well is in operation and pump was running during my inspection.

Note: Pressure levels are nearing maximum allowable limit suggest possible acid job on well to clean up formation and hopefully lower injection pressures,also old 300 bbl on site needs to be removed from site.

0789827267 2013-09-09 Salt Water Injection Well No Violations Well is down for repair.
0801760308 2011-07-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and company owned vac truck was unloading at facility during my inspection.

Note: Injection pressure is nearing maximum allowable pressure suggest possibly performing acid job on well to lower injection pressures.

0805627907 2006-05-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Pump was in operation on the day of my inspectiom. Housekeeping needed in tank area. Note: Leaks on pump need attention!

0807362365 2006-12-14 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Noted that pressure has been applied to annulus of tubing,also need seed&mulch below vault area to help hold down possible erosion issues.

0812414347 2007-01-02 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump was not in operation today,suggest placing some stone around facility to help control tracking of mud onto twp. Road also housekeeping needed in vault area.

0824361904 2008-06-02 Salt Water Injection Well No Violations No violations noted ,facility appears to be in satisfactory condition this inspection.

Note Pump was not in operation during my inspection,housekeping needed in tank area and unloading pad area suggest a good steam cleaning in both areas.

0848013739 2016-06-16 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
0856242428 2017-08-30 Salt Water Injection Well No Violations Well is down due too fact of lack of customers.


Note: Area has been recently mowed and weedeated.

0870590035 2004-12-07 Salt Water Injection Well No Violations On site to check pressures on tubing&annulus of well due to presssure reading on prior inspection,suspect loss of mechanical integrity.

6 &7Pressure equalizing-Called Tom Tomastik and requested Suspension Order. Called Gib Wetzler company rep aand told him well was down until repairs were made on well.

0871419498 2013-10-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that stone needs to be applied to area below unloading pad area too help minimize tracking mud onto county road.
0876233284 2015-10-21 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on injection pump to be repaired/replaced and owner is working on plan to replace all of the storage tanks at the facility.
0893929305 2008-07-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump was in operation during my inspection, also tank area is in need of a good cleaning and stone is needed around facility.

0899632589 2006-08-15 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump not in operation today,weedeating needed around facility as time permits!

0909072365 2015-07-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0912955798 2014-06-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Select Energy truck was unloading at facility during my inspection.
0921782596 2009-04-29 Salt Water Injection Well No Violations Inspection revealed that well is in operation pump was running during my inspection talked to well tender concerning placing more stone around facility to help minimize tracking mud out onto county road he agreed also suggested that they perform housekeeping around unloading pad area.
0929329659 2009-02-12 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection.

Note: Stone is needed around facility to help reduce tracking mud&debris out onto county rd.

0930574425 2014-04-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and owner had personnel on site to pressure test annulus of tubing.
0961342767 2008-02-06 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: 0 PRESSURE ON ANNULUS OF TUBING WILL NEED TO HAVE PRESSUE APPLIED TO IT!!!!.

0977879251 2007-06-05 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted that operator has applied pressure to annulus of tubing since my last inspection,pump was in operation during my inspection noted small leak on #2 cylinder will monitor pump for possible future repairs needed.

0994328191 2019-04-16 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and it was noted that two Ryan Environmental tankers were on site offloading during my inspection.
0995709441 2015-05-06 Salt Water Injection Well No Violations Injection pump running today and one company owned vacuum truck unloading at the facility.

Specific gravity 1.090.

0996432835 2007-03-09 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection,pump was not in operation during my inspection,housekeeping needed in vault area and stone in needed around facility.
1034570819 2003-09-24 Salt Water Injection Well No Violations No violations noted this inspection.

Note:New stone around facility since last inspection,weed eating done the well site is in best condition that Ive seen it since becoming inspector.

1047397194 2003-03-11 Salt Water Injection Well No Violations No violations noted this inspection.

(11) housekeeping in unoading area Note:Need stone around facility.

1050030472 2003-04-08 Salt Water Injection Well No Violations No violations noted this inspection.

(11)House keeping in unloading area (3)Housekeeping in tank area. STONE NEEDED AROUND FACILITY! Motor on vault pump still needs replaced.

1055681606 2017-10-20 Salt Water Injection Well No Violations Well is not in operation at this time.
1061239667 2018-07-11 Salt Water Injection Well No Violations Rhodes tank company on site changing out 2-210 bbl. tanks at the facility.
1062930636 2003-09-05 Salt Water Injection Well No Violations No violations noted,facility appears to be in good repair.

(5)clean-up needed in vault area (11)housekeeping needed in unloading area Suggest preforming M.I.T.test on well,contact inspector prior to doing so to enable him to witness test.replace 1/4 valve on annulas side of wellhead.

1069175924 2003-11-18 Salt Water Injection Well No Violations No violations noted,facility appears to be in good repair.

(11)Housekeeping in unloading area needed.

1070488336 2003-01-14 Salt Water Injection Well No Violations [11] House keeping on unloading pad

Vault sump needs attention Facility appears in compliance,no violations noted this inpection.

1071053832 2003-12-09 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition.

More stone needed around facility (9)#1 cylinder on pump needs attention(bull wheel side) (11)housekeeping needed in unloading area.

1073011149 2016-04-20 Salt Water Injection Well No Violations On site to witness pressure test of new two inch flowline they pressured up on flowline too 1600 psi and we monitored pressure for fifthteen minutes with no decline in pressure.

Note: .218 wall line pipe was used for flowline.

1075654766 2003-07-03 Salt Water Injection Well No Violations No violations noted.

(9)electric motor on pump in need of repair. (11)housekeeping in unloading pad area needed.

Called Co. Rep for repair request.

1079051308 2004-03-10 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(3)more stone needed in tank area,tank area needs a good steam cleaning when weather permits. (9)work has been prefrmed on pump since last inspection. Pump was running on day of my inspection.

1079949418 2013-02-23 Salt Water Injection Well No Violations On site along with Eric Conrad to monitor truck traffic and perform well inspection.

Six company owned trucks UIC#25-359 unloaded at facility and two Myers trucks UIC#25-427 unloaded drivers stated they picked up water from pit site in West Virginia in the Marshall county area and it belonged to Noble Energy SLH#3 well pad. Note: Electrical issues were encountered while we were on site and well attendant called for electrician to correct problem with power outages.

1082796874 2010-05-24 Salt Water Injection Well No Violations Stopped by well site too check and see if recent acid job on well helped injection pressure it was noted that current pressure was at lowest point it has been in quite some time.
1086146194 2019-11-29 0:00 SW No Violations
1089828038 2017-11-16 Salt Water Injection Well No Violations Inspection today revealed that approximately 60 ton of oil soaked dirt has been removed from spill area and workers are still bagging up leaves and small brush from wooded area cleanup below fence is nearly complete will address area below vault on Monday11/20/17.
1093915581 2019-9-23 0:00: SW No Violations
1094747751 2004-09-08 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(4)freshwater needs to be removed from dike area to allow for capacity in the event of spill.

1103814383 2004-12-22 Salt Water Injection Well No Violations On site to witness pulling of tubing&packer.

Pulled 167 jets.&packer out of hole total footage5451.15 overall including packer. Will run new 2 3/8 J-55 EUE BACK IN HOLE 12-27-04. Packer rebuilt by Backer Industries,ClarksburgWV.

1104323882 2004-12-28 Salt Water Injection Well No Violations On site to witness setting of packer and placing of fresh water and anhib in annulus of tubing.

Flushed well with 78 bbl fresh water and 5 gal. Anhib,pressure tested well at 1270 psi for 15 min. with no decline in pressure.(Test Passed). Witnessed placing of acid and salt water placed in well bore to help clean up injection zone well will be shut in over night before disposal operation resumes.

1105035106 2005-01-06 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Better restoration work needed around wellhead area site of working pit from recent work preformed on well. Stone needed around driveway area.

1114209444 2005-04-20 Salt Water Injection Well No Violations Stopped by well site to check on roustabout crew preforming work at site they have cleaned out old storage tanks and replaced with new ones (4-210 bbl tanks),they stated that plumbing work on tanks should begin as early as next week,told crew that I would inspect progress next week.
1116162943 2005-05-13 Salt Water Injection Well No Violations Stopped by well site to check on progress of welders replumbing entire piping system at disposal well,at the time of my inspection their was nobody present.
1118443644 2005-06-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted 3valves on laydown tanks in need of having plugs installed,also 2valve on pump in need of replacement,replumbing of facility nearly complete,stone will need to placed through out tank area! Pump was running on the day of my inspection.

1123410015 2005-08-04 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Stone is needed in area of flow lines,screen needed on sump hole within dike,general housekeeping needed throughout entire facility.

1125686031 2005-08-31 Salt Water Injection Well No Violations Stopped by injection well to check on status after recent storm discovered vault ran over contactedKen Parsons and he stated he would come look at affected area and have crew preform required cleanup.
1127688026 2005-09-23 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Stone needed in tank area! Housekeeping needed in unloading area also stone is needed around facility to cut down on mud being tracked out onto township road.

1131790934 2005-11-07 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump not running today,stone is needed around facility .

1132060586 2005-05-04 Salt Water Injection Well No Violations No violations noted ,facility appears to be in satisfactory condition this inspection.

Roustabout crew still working on welding up new 3&2 piping,well owner is replacing all lines at site and adding 2 additional 210bbl storage tanks.

1134154184 2005-12-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump not running on the day of my inspection.

1142401179 2009-09-04 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation during my inspection, housekeeping needed in tank area.

Note: Stone is needed in area of unloading pad and entire tank area.

114270476 2017-6-6 0:00:0 SW No Violations
1145259510 2011-08-11 Salt Water Injection Well No Violations Inspection revealed that pump was in operation and is operating at maximum operating pressure, Company rep John Gaddos stated they are planning on performing acid job on well in the very near future and they also plan on removing 1 -300 bbl storage tank and 1 open top 200 bbl tank from site.
1146085453 2006-04-21 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Pump was running on the day of my inspection.Noticed tranfer pump at vault removed possibly being repaired.

1152887459 2006-07-11 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted: Weedeating was being done during my inspection,pump was in operation and two copany trucks were unloading at facility during my inspection,checked log book of drivers everything appeared to be up to date!.

1159076145 2010-03-16 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation today, on site to witness operator have pressure applied to annulus of tubing they applied 500# and I monitored pressure for 15 min with no decline in pressure.

Note: Stone has been applied to area around unloading pad but more stone is needed in tank area.

1164364590 2006-11-21 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.Noted that annulus pressure has declined since last inspection noted that 2 valve appeared to be wet on seam sospect problem with valve seals contacted local well tender and and he stated that he would replace valve and have company owned solvent truck apply pressure to annulus of tubing.
1176174140 2007-11-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Request well owner apply positive pressure to annulus of tubing,call inspector prior too doing so!!housekeeping needed within unloading pad area.

1183221269 2005-04-15 Salt Water Injection Well No Violations On site to witness roustabout crew seal up cracks in concrete in tank area(filled with tar and covered with sand)painted bottoms of new tanks to be placed in tank area(4-210bbl storage tanks).Operator stated they would place tanks within tank area next week .
1186187140 2007-08-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Area around vault in need of housekeeping&tank area also needs a good cleaning! Pump was not operating on the day of my inspection.

1202047988 2018-06-06 Salt Water Injection Well No Violations Inspection revealed that new owner was on site performing housekeeping tasks.
1208027844 2011-02-22 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection.

Note: Stone is needed around facility and old storage tanks still need to be removed from site and pump house is in need of repair/replaced.

1209814192 2008-05-01 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Steam cleaning of tank area requested once entire area is cleaned reseal cracks below tanks to ensure no brine is allowed to seep into soil below.

1214359037 2014-03-07 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one company owned vacuum truck was unloading at facility during my inspection.

Note: Told operator that positive pressure will need to applied to annulus of tubing ASAP.

1218235430 2008-08-07 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Note: Pump was in operation during my inspection, also note cleaning in tank area is needed as soon as weather permits,also stone is needed in unloading area too help reduce tracking of mud onto township roadway.

1220938475 2004-08-03 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(1)I.D.at tank site needs to be replaced with proper I.D.(Arvilla) (2)I.D.at wellhead needs replaced(Arvilla)

1225749649 2008-11-03 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation today,noted that housekeeping is needed in tank area and stone is needed around facility to help from tracking mud out onto township road.
1228441243 2005-02-04 Salt Water Injection Well No Violations

No violations noted, facility appears to be in satisfactory condition this inspection. Pump running today. (9)#1 CYLINDER on pump in need of repair. (12)Better restoration work needed in area of wellhead.

1228503694 2008-12-04 Salt Water Injection Well No Violations Inspection revealed that pump was in operation during my inspection,stone is still needed around facility to help with mud being tracked out onto county road.
1231192694 2009-01-05 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection.

Note: Talked to company rep concerning getting stone spread around location to help cut down on tracking mud out onto county road he stated that he would advise supervisor of request.

1232395679 2013-07-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that three company owned vacuum trucks were at facility during my inspection.
1234398277 2014-01-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one Enervest Operating vacuum truck was unloading at facility during my inspection.
1236154952 2010-09-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today, noted that unloading line was in need of replacement and discussed matter with well tender and he stated that crew had been called out to replace line.
1240448467 2017-12-08 Salt Water Injection Well No Violations On site today to witness contractor change out unloading pad vault it was discovered that it had a small hole in it and needed replaced.
1248848273 2017-11-17 Salt Water Injection Well No Violations Inspection today indicated that new soil has been delivered to site and vacuum truck and steamer was on site preparing to steam clean vault they were waiting on fresh water at the time of my inspection will check back with them on Monday.
1255903426 2019-9-26 0:00: SW No Violations
1259i9 2002-6-18 0:00: SW No Violations
1260823066 2009-12-14 Salt Water Injection Well No Violations Inspection revealed that pump was in operation today, noted fresh water build up in dike area suggested to well tender to drain water to vault and pump it into storage tanks.

Note: Stone in needed at facility to help cut down on tracking mud out onto state highway and causing hazards.

1265103002 2006-03-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Housekeeping needed in tank area, when weather permits steam cleaning needed in said area. Vault pump is still in need of replacement.

1267483861 2010-03-01 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection.

Note: 2 valve on annulas side of tubing needs to be replaced it is showing signs of leakage,once valve is replaced you will need to have positive pressure applied to it.

1272019171 2011-08-30 Salt Water Injection Well No Violations Inspection revealed that well is in operation and pump was running during my inspection.

Note: Tank 2 needs to be emptied and removed from site and injection pressure is nearing maximum allowable pressure suggest preforming acid job on said well.

1274471667 2010-05-21 Salt Water Injection Well No Violations On site to witness acid job preformed on well, Producers Services pumped 2000 gal of 15% acid in well at average rate of 1.1 bpm with maximum pressure noted@1270 psi displaced with brine 2780 gal and ISIP was 796psi and after 5 min it had declined to 670 psi operator shut well in for the weekend will resume operations on 5/24/2010.
1275676266 2010-06-04 Salt Water Injection Well No Violations Inspection revealed that well is not in operation today well tender stated that as soon as they had enough water in tanks they resume operations.

Note: Pump house is showing signs of severe rotting it will need to be replaced in the near future.

1278295446 2014-12-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that unloading pad area is in need of a good cleaning.
1281129500 2010-08-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection, noted that weed eating has been preformed at site since my last inspection.

Note: Area where flow line repair took place is in need of stone.

1284837210 2010-09-17 Salt Water Injection Well No Violations Inspection revealed that Producers Services&Baker Hughes were on site to pump chemicals in well bore to reduce iron sulfide buildup in injection zone, they mixed chemical and displaced through tubing at a average rate of .5 bbl per min and did not exceed maximum injection pressure, will shut well in overnight and resume testing in the morning.
1291061688 2010-11-26 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: As we discussed removal of oil tank(open top) and the 300 bbl that is bypassed as weather permits they need to be removed from site.

1294805627 2017-11-29 Salt Water Injection Well No Violations Operator on site pumping down water that was in storage tanks and also working in area of recent spill zone the area below the fence is completed and they are waiting on a new vault to arrive and be installed before they can complete cleanup at site.
1301384230 2016-03-07 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Two company owned vacuum trucks were on site unloading during my inspection.

1302045162 2011-04-04 Salt Water Injection Well No Violations Inspection revealed that pump was in operation during my inspection.

Note: Old tanks still need to be removed from site and stone is needed in unloading area.

1308011736 2011-06-13 Salt Water Injection Well No Violations Inspection revealed that pump was in operation today and it was noted that dike wall has been repaired as requested as of my last inspection.
1319742008 2014-10-20 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one H&L Water Service vacuum truck was unloading at the facility during my inspection.
1321396996 2011-11-15 Salt Water Injection Well No Violations Stopped by service rig for update on when they might possibly want too run Packer back in well. They were still drilling out the fill up that is in the casing. Once the bottom is reached they will circulate the hole clean, reperforate, then run a Halliburton rebuilt packer in hole and then perform the acid job.
1322213921 2011-11-22 Salt Water Injection Well No Violations On site to witness operator attempt to start new packer in well. It was determined that well was not static and the decision was made to kill the well. Formation Cementing was called to mix CACL to make well static after which they will attempt to run packer.
1322218276 2011-11-23 Salt Water Injection Well No Violations On site to witness operator attempt to run Baker Packer in well. Company rep called Baker personnel to try to figure out why Packer would not go down hole. Baker stated they would send a representative to site on 11/25/2011 to try to determine/remedy the problem.
1322607339 2011-11-29 Salt Water Injection Well No Violations On site to witness setting of the packer and the casing intergrity test. The packer was set at 5437. The tubing annulus was pressure tested to @ 1550 PSI and the pressure was monitored for 15 minutes with no decline in pressure. Baker Tool ran a plug in bottom of packer with sheer pins in place that would break off once pressure was applied to tubing. However, after applying @ 6000 PSI the decision was made to swab tubing dry, drop a steel bar in tubing to sheer off plug and then perform acid job on said well.
1322696022 2011-11-30 Salt Water Injection Well No Violations On site to witness operator attempt to free obstruction from inside of tubing. They ran small tools in hole and hit an obstruction at 4500. They then decided to swab tubing and it was determined that the vacuum truck they were using for fresh water source had been hauling dirty water and they apparently pumped fines down hole when we were attempting to flush hole clean and conduct the casing integrity test on 11/29/2011. Baker Tool is making a tool (sand pump) to remove the obstruction from the tubing.
1322868165 2011-12-02 Salt Water Injection Well No Violations On site to witness retesting of casing integrity and the acid job preformed on well. Producers Services flushed the tubing annulus with 80 barrels of inhibitor laden fluid. The tubing was then attached to the packer and pressured tested to @ 1550 PSI. The pressure was monitored for 15 minutes with no decline in pressure. They then proceeded to pump on the tubing to release plug that was installed on bottom of the packer. The plug released at @ 5575 PSI and then the acid job was started on the well. They pumped 2000 gallons of 15% acid and displaced it with 20 barrels of fresh water. The well was shut in for the evening and Producers Services rigged down their equipment. The company representative then decided to start to re-plumb the well head and get the well ready to put back into operation.
1324333453 2011-12-19 Salt Water Injection Well No Violations Stopped by site for update they are still in process of having tanks cleaned out and they are waiting on service rig to set plug in packer and test tubing for leaks or replace seals on down hole tool assembly.
1325879504 2012-01-05 Salt Water Injection Well No Violations On site to witness testing of tubing too check for possible depth of leakage, Blue Dot Energy Services set plug in packer and then we pressured up on tubing to 500 psi and monitored annulus and within 10 min pressure was at 200 psi knowing we now have leakage in tubing we then proceeded to set bridge plug inside of tubing@5398 and pressured up tubing to 1250 psi and it leaked off to 800 psi within 15 min so then they proceeded to move plug up hole to 4300 and tested again and once again test failed then they moved plug up hole tp 2030 and once again test failed and then decision was made to order new string of tubing it should be on site 1/10/12 and service rig is too be on site the same day to remove old tubing and then they will start new string in well and once on bottom we will flush annulus and replace it with fresh water and inhibitor and repressor test well.
1326568491 2012-01-13 Salt Water Injection Well No Violations Inspection revealed that Whipstock Services were on location pulling tubing to inspect on/off tool for possible damage they will run tubing back in well 1/16/2012 and retest annulus of tubing.
1326755538 2012-01-16 Salt Water Injection Well No Violations On site to witness testing of annulus of tubing Producers Services pressured up to 1550 psi and we monitored pressure for 15 minutes with no decline in pressure.(TEST PASSED).

Note: Stone is needed around facility and 500 bbl tanks that were used during workover procedure need to be removed from site.

133116845 2004-6-7 0:00:0 SW No Violations
1331336768 2012-03-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and well tender stated that they were taking a lot of flow back water in that is why injection pressure is elevated told him to monitor pressures and do not exceed maximum injection pressure.

Note: Stone has been placed around entire facility and old storage tanks still need to be removed from site.

1332201291 2012-03-20 Salt Water Injection Well No Violations On site to witness Producers Services apply pressure to annulus of tubing they pressured up to 547 psi and we monitored pressure for 15 minutes with no decline in pressure.
1336644851 2012-05-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Well tender has cleaned up facility and has cleaned brush away from fence that surrounds facility and is in process of having dike walls raised to be in compliance with SPCC rules.

1348264208 2016-08-18 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation and there was no company personnel present during my inspection.
1353982414 2018-09-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that two CS Trucking had two vacuum trucks on site today during our truck audit.
1356984821 2012-12-31 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Two G-R Contracting vacuum trucks were unloading at facility during my inspection(UIC#25-271).

1358535647 2013-01-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and there was one company owned vacuum unloading at facility during my inspection.
1361992860 2013-02-23 Salt Water Injection Well No Violations I am onsite with Inspector Dave Ball. Six Select waster trucks UIC #25-359 unloaded at the facility. Two Meyers trucks UIC #25-427 unloaded. The drivers stated that they picked the water up in the Dallas Pike area of West Virginia from a Noble Energy pit. NOTE: the facility encountered electrical issues while we were onsite.
1363144618 2018-10-11 Salt Water Injection Well No Violations Stopped by site to check on owner changing out storage tanks they removed 1-400 bbl. Tank and replaced it with a new one and they were plumbing it up during my inspection.
1365977860 2013-04-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that well tender is in process of steam cleaning tanks and unloading pad area.
1370184678 2019-04-04 Salt Water Injection Well No Violations Injection pump in operation during my inspection.

Note: Two Ryan Environmental tankers on site offloading during my inspection.

1376452018 2016-02-03 Salt Water Injection Well No Violations Inspection revealed that facility is not being used at this time.
1379202505 2013-09-13 Salt Water Injection Well No Violations Inspection revealed that service rig was tripping bit out of hole they plan on running new bit back in hole and then shut down for the weekend and they will resume cleanout efforts on Monday.
1379419120 2013-09-16 Salt Water Injection Well No Violations On site to witness setting of CIBP @ 5577 AND THEN Appalachian Well Survey perfed Clinton Section there were 144 shots from 5512-5572 they will start rebuilt packer and used tubing into well tomorrow.
1379460806 2013-09-17 Salt Water Injection Well No Violations On site to witness tubing and packer run into well bore, Kilbarger Services ran Baker A-3 Set Lock and setting depth was 5435 and once packer was set they used on/off tool to release from packer and then they circulated fresh water & inhibitor and once inhibitor was in place they hooked back up to tubing string and Producers Services pressure tested annulus of tubing at 1600# for 15 minutes with no decline in pressure.

Note: Acid job was performed on well they pumped 1000 gallon of 28% acid with a average pressure of 1640 and once acid was displaced and ISIP was1114 and 15 minute pressure was 972 and still falling and operator will plumb up wellhead and resume operation tomorrow.

1379543143 2013-09-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and operator was in process of cleaning up site of recent work over of well.
1385747058 2013-11-29 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one company owned vacuum truck was unloading at facility during my inspection.
1386791361 2013-12-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that annulus pressure had fallen off and operator stated that 2 valve had frozen and busted and relieved annulus pressure and as soon as they could get service company to come to well site and apply pressure they would contact inspector to witness testing.
1388148931 2013-12-26 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that three company owned vacuum trucks were unloading at facility during my inspection.
1389215429 2014-01-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and operator stated that they had six company owned vacuum trucks expected too arrive on site before noon today.
1391810462 2014-02-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that one company owned vacuum truck was unloading at facility during my inspection.
1398591023 2014-04-23 Salt Water Injection Well No Violations On the day of my inspection I accompanied Dave Ball. Pressures on well were 620 lb on tubing and 1170 lb on the annulas. Pump was down for repair. No violations noted.
1420254080 2011-11-28 Salt Water Injection Well No Violations On site to witness running of tubing in hole and setting of the Baker packer at 5437. They will perform the required tests tomorrow and also acidize the well passes the tests.
1423574334 2018-06-04 Salt Water Injection Well No Violations Meeting with new well owner at the site to discuss facility and expectations of the dos and donts of a injection well owner.
1424810619 2015-02-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one H&L Water Services had one vacuum truck at the facility unloading brine from a Eclipse well pad.
1427278352 2014-09-29 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one H&L Water and one Jayhawk Water Service vacuum trucks were unloading at the facility during my inspection.
1434594796 2018-08-27 Salt Water Injection Well No Violations Cleaning of facility still continues new owner hopes to be up and running in the near future.
1449701739 2009-03-04 Salt Water Injection Well No Violations Inspection revealed that pump was in operation today,talked to well tender about getting stone placed around facility to help cut down on tracking mud out onto highway he stated he would contact his supervisor and make him aware of our discussion.
1451593388 2015-12-29 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on fittings to complete pump change out at the facility.
1452029154 2016-01-05 Salt Water Injection Well No Violations Still waiting on plumbing to be completed at the facility.
1458562974 2016-03-18 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and I met with company reps to discuss the possibility of drilling another well on the lease.
1460147026 2004-12-21 Salt Water Injection Well No Violations On site to witness unseating of packer and pulling of tubing,operator pulled 4jts. And let set over night will resume operation tomorrow.
1472240690 2016-08-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one Summit Environmental vacuum truck was unloading at the site during my inspection.
1477425275 2016-10-25 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.
1487350156 2017-02-17 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that three Evolution tankers were on site unloading product during my inspection.
1498861349 2017-06-29 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that six AOS vacuum trucks were unloading at the facility during my inspection.
1506715562 2009-12-28 Salt Water Injection Well No Violations Inspection revealed that well was in operation during my inspection.

Note: Stone is needed around facility to help cut down on tracking mud onto township road.

1508350650 2020-7-21 0:00: SW No Violations
1509397466 2016-11-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one ECM tanker was offloading during my inspection.
1510601513 2017-11-13 Salt Water Injection Well Violations Noted Inspection today indicated that locks at the facility have been changed and I was unable to check pressures but I discovered that unloading pad vault appeared too have run over and there was small amounts of oil and brine noted outside of fenced in area noticed kill area 30 long and approximately 5 wide and photos were taken of area.

Contacted company and they are sending representatives from Texas to discuss clean up needed at site, told them to remove all contaminated soils and properly dispose of in EPA approved landfill and replace with new soil and seed and mulch area and submit plan to rebuild area around vault to prevent any future P&C violations.

1512761400 2017-12-06 Salt Water Injection Well No Violations Clean up continues in tank area and contractor is going to remove old vault tomorrow and place new one on Friday 12//8/2017.
1518545387 2018-02-11 Salt Water Injection Well No Violations Stopped by site to check on water build up in tank area there was approximately 20 bbl. Of fresh water within dike area contacted Ken Parsons and requested that they send someone to site to pump fresh water into storage tanks and pump in down hole the next time they inject fluid down hole.
152054602 2016-2-24 0:00: SW No Violations
1521050199 2018-03-14 Salt Water Injection Well No Violations Well is currently not in operation.
1528745459 2018-06-11 Salt Water Injection Well No Violations Inspection revealed that owner was changing out old storage tank and replacing it with a new one.

210 barrel tank was swapped out today. Well is not in operation at this time due to fact new owner is waiting on transfer to be completed.

1529245546 2005-07-12 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump was running during my inspection. Operator needs to apply stone around facility in area of tanks! Noted new building erected on site for storage of supplies.

1532725194 2018-07-25 Salt Water Injection Well No Violations On site today to witness Producers Services perform 1500 gallon acid treatment on well they placed acid in well and displaced it with 30 bbl. of water and then shut well in.
1544371723 2018-12-05 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during our inspection.

Note: Three CS Trucking tankers were on site during our inspection.

1547905367 2019-01-17 Salt Water Injection Well No Violations On this day of my inspection it was noted that injection pump was in operation and one CS Trucking and one JHAWK vacuum truck were on site offloading during my inspection.
1549031017 2019-01-31 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that one CS Trucking tanker was on site offloading during my inspection.
1549996052 2019-02-11 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was noted that one Stallion Oilfield Services vacuum truck was offloading at the facility during my inspection.

Note: Dike was free of fresh water build up and sump pumps were in good working order today.

1551467539 2019-02-28 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that two Ryan Environmental vacuum trucks were offloading during my inspection.
1551634801 2016-06-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that one Summit Trucking vacuum truck was unloading at the facility during my inspection.
1551984215 2019-03-06 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and it was noted that two Ryan Environmental trucks were offloading at the facility during my inspection.
1555794757 2019-04-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Two Ryan Environmental tankers were on site offloading during my inspection.

1560262278 2004-02-04 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(3)clean up needed in tank area (9)packing on fluid end of pump needs replaced or replacement fluid end needed. (11)housekeeping needed in unloading area Note:MORE STONE NEEDED AROUND FACILITY!

1567243365 2019-8-26 0:00: SW No Violations
1568019527 2019-9-3 0:00:0 SW No Violations
1573527744 2016-05-18 Salt Water Injection Well No Violations No activity at the site today.
1584047467 2020-3-10 0:00: SW No Violations
1584909736 2004-07-01 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(3)#1 laydown tank has small seep in bottom area request that it be repaired or replaced.

1599496664 2018-08-20 Salt Water Injection Well No Violations Witness setting of new 140 barrel storage tank that feeds the injection pump old one was showing signs of fatigue.
1600051468 2009-11-03 Salt Water Injection Well No Violations Inspection revealed that well is in operation,pump was not running during my inspection it appeared that pump had recently shut down,noted that recent plumbing ork had been preformed on discharge side of pump.

Note: Truck number 1424 is in need of tank repair,noted seepage on bottom of tank.

1601336507 2017-06-22 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation upon my arrival on site informed operator Jonathan Mika to cease operations due to Chiefs order issued for no insurance on wells he turned off injection pump and called his supervisor Jordan Monroe and informed him of my request after contacting Central office it was discovered that insurnce policy has ben received and I called them later in the day and told them they could resume operations at the site.

Note: Two AOS vacuum trucks were on site and one ECM tanker also wason site.

161550408 2005-4-6 0:00:0 SW No Violations
1622268370 2010-11-03 Salt Water Injection Well No Violations Inspection revealed that well is in operation and pump was in service on the day of my inspection.

Noted: That plumbing on storage tanks is in process of being replaced. Note: There are two empty and faulty tanks at faulty that needs to be removed from site and old oil storage tank needs to be removed also.

1628939961 2014-07-14 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water Service vacuum truck was unloading at facility during my inspection.
1641033118 2005-10-07 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted:2 valve on annulus of tubing head has been replaced at request of inspector also noted that partial painting of storage tanks has been completed. Would like to have more stone placed within tank area!

1665438526 2018-04-27 Salt Water Injection Well No Violations Well not in operation at this time(sale pending).
1666888435 2007-05-03 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Note: Pump was in operation during my inspection, noted that annulus pressure was at 0 called and left message with company rep Ken Parsons to havepressure applied to annulus of tubing,housekeeping needed in tank area as weather permits(steam cleaned) also reseal any cracks in concrete to ensure of no possible leakage into soil surrounding area.

1674113462 2015-05-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation on the day of my inspection.
1675329507 2012-02-01 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation today due to lack of water, it was noted that stone has been placed around facility and filer system still needs to be hooked up and pressure needs to be applied to annulus of tubing as soon as possible.
1676019344 2016-09-20 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1680968163 2018-12-16 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and operator stated they are currently receiving twelve loads of brine per day.
1684831943 2013-09-17 Salt Water Injection Well No Violations On site to witness tubing and Baker A-3 Set Lock run into well and Producers Services will perform acid job once packer is set and inhibitor is placed into well and annulus of tubing pressure tested.
1695921836 2010-10-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection, no upgrades at site have been preformed since my last inspection, company rep stated that old storage tank were to be removed and new ones installed and upgrade made to pump house.

Noted two Select Energy vac trucks were unloading at facility during my inspection.

1720466372 2002-10-30 Annular Disposal No Violations Sump pump running,but needs rewired.
1726371919 2017-05-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.


Note: Water samples were taken and transported to Cambridge lab for analytical results.

1737486473 2004-10-26 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

(11) Cleanup needed in unloaading pad area.

1739244398 2006-03-30 Salt Water Injection Well No Violations No violations noted,facilty appears to be in satisfactory condition this inspection.

Pump not running today. Suggest replacing tranfer pump at vault,housekeeping needed in tank area.

1741700741 2015-04-28 Salt Water Injection Well No Violations I am on site to witness tubing and packer run into the well bore, Kilbarger Services ran a Baker A-3 Set Lock packer to a depth of 5268. The packer was not set and activity is suspended until additional tubing arrives tomorrow.
1756566168 2018-04-11 Salt Water Injection Well No Violations Inspection revealed that unloading pad has been drained and containment area was free of standing water today.
1758763216 2016-07-20 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection and it was noted that one 25-548 tanker and one 25-534 vacuum truck was unloading at facility today.
1761096714 2003-10-03 Salt Water Injection Well No Violations No violations noted facility appears to be in good repair.

(11)housekeeping needed in unloading area.

1764580609 2014-08-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one company owned vacuum truck was unloading and one H&L Water Service was also unloading at the facility during my inspection.
1774133955 2008-09-04 Salt Water Injection Well No Violations No violation noted, facility appears to be in satisfactory condition this inspection.
1807049475 2014-04-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and in conversation with well tender stating that they have been slow this week receiving water.
1833833832 2018-08-17 Salt Water Injection Well No Violations Inspection today revealed that new owner has replaced old pumphouse with a new building and also the old office building has been replaced since my last inspection and new owner hopes to be receiving water within the next couple weeks.
1852559050 2011-11-04 Salt Water Injection Well No Violations On site to witness Whipstock service rig attempt to release Baker packer. They are not accustomed to working with this type of packer. I suggested to company man that they get a Baker representative on site to assist with getting the packer released. They will resume service operations on 10/7/2011.
1861868850 2019-11-7 0:00: SW No Violations
1862547978 2007-12-03 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Note: Annulus pressure needs to be applied to backside of tubing,unloading pad was standing full of water, drain to vault tank needs to be checked for blockage.Pump was not in operation during my inspection.

1873571899 2016-03-29 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation.
1891282790 2012-07-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and they were unloading mini hoe at site so they can better maintain dike wall and clear out around fencing at facility.
1892629276 2007-02-06 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Annulus test completed 1/24/07. Pump was not in operation during my inspection well does not appear to be used much during severe weather conditions due to fact of road conditions.

1914697768 2013-07-31 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one company owned vacuum truck was unloading at facility at this time.
192126893 2005-4-27 0:00: SW No Violations
19477059 2002-10-30 0:00 SW No Violations
1958967452 2007-10-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Positive pressure needs to be applied to annulus of tubing,contact inspector prior to doing so! He wants to witness pressure being applied to backside of tubing. General housekeeping needed in vault area.

1998846483 2013-09-10 Salt Water Injection Well No Violations My inspection today finds the service rig is at a depth of 5553 with the tubing and bit. The bit plugged up and the rig is preparing to trip the tubing.
2023885446 2019-02-24 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that two Ryan Environmental vacuum trucks were on site offloading during my inspection.
2030390827 2008-04-02 Salt Water Injection Well No Violations No violations noted, facility appeared to be in satisfactory condition this inspection.

Note: Pump was in operation during my inspection injection pressure seems to be increasing possibly well is in need of acid job preformed on it to help lower pressures? Also stone is needed around facility.

2035437646 2009-10-06 Salt Water Injection Well No Violations Inspection revealed that well is in operation pump was running on the day of my inspection.

Note: Stone is needed at site to help cut down on tracking mud out onto county road and also pressures are getting close to maximum pressure you might consider preforming a small acid job on well to help cleanup formation and lower injection pressure.

2040004597 2006-09-14 Salt Water Injection Well No Violations No violations noted, facility apears to be in satisfactory condition this inspection.

Pump not running today,several leaks on pump noted operator will need to repair leaks also noted drain line to vault is apparently plugged fluid level in tank area was near top of concrete called local driver and suggested he pump out tank area.

2049793209 2011-11-25 Salt Water Injection Well No Violations On site to witness the running of the Baker (A-3) packer and tubing in the hole. They ran approximately 60 joints of using 2.375 used tubing in well when the rig had mechanical problems. They will resume operations as soon as rig is repaired.
2060318855 2016-06-07 Salt Water Injection Well No Violations Injection pump not in operation during my inspection and it was noted that two 25-609 vacuum trucks and one 25-534 truck was unloading at the facility during my inspection.
2061110833 2019-7-12 0:00: SW No Violations
2077709241 2013-07-17 Salt Water Injection Well No Violations On site along with company rep Jonathan Mika to perform pressure testing of annulus of tubing he hooked up pressure washer and placed 1530 psi on backside of tubing and we monitored pressure for 15 minutes with no decline in pressure.

Note: Test passed.

2100716416 2017-03-14 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection.

Note: One JHAWK vaccum truck was unloading at the facility during my inspection.

2109517176 2018-02-16 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection and it was noted that fresh water has accumulated in tank and unloading pad area called company contractor and requested that they pump water into storage tanks and pump it down hole the next time they inject fluids down hole.
2117273239 2015-03-11 Salt Water Injection Well No Violations Well has equalized called central office and let them be aware of situation and owner is trying to get service rig scheduled to perform tubing/packer replacement job.

Note: Ordered company rep to cease operations until corrections are made to replace tubing/packer.

2119049732 2006-02-01 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted: Stone has been spread around drive could use some in tank area also tranfer pump at vault in need of being replaced housing is broke on the one at well site also need to apply pressure to annulus of tubing minimum of 200 psi.

2122935242 2017-11-14 Salt Water Injection Well Violations Noted Clean up continues in area down below vault area, soils are being removed and area cleaned of small amounts of oil that was spilled due to vault running over.

Well is not in operation at this time it has been down approximately four months.

2125369913 2007-09-10 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Conversation with well tender requesting he square up barrier around well to allow better access to valves on wellhead he stated as soon as roustabout crew came by with front-end loader he would perform required task.

2127081626 2010-07-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection, noted that weed eating has been partially preformed around tank area and there was two company owned trucks unloading at facility during my inspection.
2127348316 2012-03-20 Salt Water Injection Well No Violations On site to witness Producers Services perform pressure test an annulus of tubing they pressured up to 547 psi and we monitored pressure for 15 minutes with no decline in pressure.
2129958927 2004-12-03 Salt Water Injection Well No Violations Pump not running.

No violations noted on the day of my inspection. Made phone call to company rep stating that I would like to be present next time they run pump to monitor pressures suspect pressure is equalizing!

2136285378 2015-08-20 Salt Water Injection Well No Violations Met with company reps to discuss replacing tanks at site and making upgrades to current unloading pad.
2143174135 2011-11-18 Salt Water Injection Well No Violations The service rig was mixing mud to circulate clean and then reperforate the Clinton formation. They plan to start the packer back in well in the near future.
2146351861 2020-6-17 0:00: SW No Violations
224344958 2013-5-8 0:00:0 SW No Violations 2.00
239090865 2011-5-6 0:00:0 SW No Violations
244911022 2016-3-16 0:00: SW No Violations
258854734 2014-5-8 0:00:0 SW No Violations
303595548 2011-10-18 0:00 SW No Violations
319587442 2018-7-12 0:00: SW No Violations
325952525 2011-12-8 0:00: SW No Violations
331201986 2003-2-5 0:00:0 SW No Violations
334564180 2006-10-4 0:00: SW No Violations
340841955 2018-1-5 0:00:0 SC No Violations
346380656 2015-6-15 0:00: SW No Violations
38386028 2004-5-10 0:00: SW No Violations
385680464 2011-3-7 0:00:0 SW No Violations
394508688 2007-7-9 0:00:0 SW No Violations
397370405 2017-6-2 0:00:0 SW No Violations
404116211 2020-2-24 0:00: SW No Violations
411429504 2005-3-14 0:00: SW No Violations
422406481 2016-12-21 0:00 SW No Violations
434146839 2015-6-1 0:00:0 SW No Violations
45060778 2006-11-6 0:00: SW No Violations
473330585 2017-11-21 0:00 SW No Violations
499321615 2017-12-22 0:00 SW No Violations
539179268 2004-1-9 0:00:0 SW No Violations
556425115 2014-4-23 0:00: SW No Violations
5604i101 2002-3-19 0:00: SW No Violations
5604i105 2002-3-20 0:00: WR No Violations 8.00
578969470 2010-1-19 0:00: SW No Violations
649291313 2010-4-13 0:00: SW No Violations 1.00
651183550 2006-6-1 0:00:0 SW No Violations
68946847 2018-5-11 0:00: SW No Violations
695229665 2018-11-21 0:00 SW No Violations
718336792 2013-4-30 0:00: SW No Violations 2.00
7306090 2020-3-3 0:00:0 SW No Violations
768362090 2004-12-27 0:00 SW No Violations 8.00
774660897 2010-5-3 0:00:0 SW No Violations 1.00
801760308 2011-7-5 0:00:0 SW No Violations
805627907 2006-5-2 0:00:0 SW No Violations
82783323 2012-1-4 0:00:0 SW No Violations
853588501 2019-6-17 0:00: SW No Violations
856242428 2017-8-30 0:00: SW No Violations
870590035 2004-12-7 0:00: SW No Violations 3.00
876233284 2015-10-21 0:00 SW No Violations
893929305 2008-7-3 0:00:0 SW No Violations
909072365 2015-7-10 0:00: SW No Violations
912955798 2014-6-12 0:00: SW No Violations
921782596 2009-4-29 0:00: SW No Violations
929329659 2009-2-12 0:00: SW No Violations
930574425 2014-4-16 0:00: SW No Violations
95690557 2008-1-2 0:00:0 SW No Violations
961342767 2008-2-6 0:00:0 SW No Violations
99292915 2016-4-18 0:00: SW No Violations
994328191 2019-4-16 0:00: SW No Violations
PL7843 PL No Violations
UIC233 1987-6-3 0:00:0 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0499321615 US-OH-125456 2018-01-13 9-3-04(A) Pollution/Contamination
1510601513 US-OH-114292 2018-01-13 9-3-04(A) Pollution/Contamination
2122935242 US-OH-121750 2018-01-13 9-3-04(A) Pollution/Contamination

For data sources see[9]

References