If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-21788 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.68,"lon":-81.47,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Enoch Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: WEBER M | |
License Status: Final Restoration | |
License Date: 2017-08-23 | |
Spud Date: 1975-11-02 | |
Spud Drilling Contractor: | |
Final Drill Date: 1975-11-08 | |
Well Total Depth: 6036.00 ft | |
Configuration: Vertical | |
Latitude: 39.680000 | |
Longitude: -81.470000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1975-09-30 | 2143 CARLESS RESOURCES INC GeoDate 9/30/75 |
Original Spud | 1975-11-02 | GMM UPDATED TO PLUG STATUS PER PLUG REPORT |
Completed | 1975-11-08 | GMM UPDATED TO PLUG STATUS PER PLUG REPORT |
Reached Total Depth | 1975-11-08 | GMM UPDATED TO PLUG STATUS PER PLUG REPORT |
Change of Owner | 1998-07-06 | Operator changed from 2143, CARLESS RESOURCES INC to 1388, NORTH COAST ENERGY INC |
Change of Owner | 2009-12-14 | Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC |
APP | 2017-08-23 | Proposed Formations:CLINTON, Issued Date:8/23/2017, Expired Date:8/23/2019 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2017-09-29 | GMM UPDATED TO PLUG STATUS PER PLUG REPORT |
Record Last Modified | 2017-11-08 | GMM UPDATED TO PLUG STATUS PER PLUG REPORT |
Construction Permit Expires | 2019-08-23 | GMM UPDATED TO PLUG STATUS PER PLUG REPORT |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5884 | 5946 | 12 |
5884 | 5946 | 12 | |
5884 | 5946 | 12 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1430 Bbl | 30000 | |||
ACID | 0 | 500 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1986 | ZILKHA ENERGY INC | 0.00 | 0.00 | 365 |
1987 | ZILKHA ENERGY INC | 2357.00 | 0.00 | 107 |
1988 | FREDERICK PETROLEUM CORP | 1868.00 | 0.00 | 366 |
1989 | FREDERICK PETROLEUM CORP | 1517.00 | 0.00 | 365 |
1990 | CARLESS RESOURCES INC | 2226.00 | 0.00 | 365 |
1991 | CARLESS RESOURCES INC | 1333.00 | 0.00 | 365 |
1992 | CARLESS RESOURCES INC | 1475.00 | 0.00 | 365 |
1993 | CARLESS RESOURCES INC | 1622.00 | 0.00 | 365 |
1994 | CARLESS RESOURCES INC | 1232.00 | 0.00 | 365 |
1995 | CARLESS RESOURCES INC | 1017.00 | 0.00 | 365 |
1996 | CARLESS RESOURCES INC | 1384.00 | 0.00 | 365 |
1997 | CARLESS RESOURCES INC | 1610.00 | 0.00 | 365 |
1998 | EXCO - NORTH COAST ENERGY INC | 1993.00 | 0.00 | 365 |
1999 | EXCO - NORTH COAST ENERGY INC | 1681.00 | 0.00 | 365 |
2000 | EXCO - NORTH COAST ENERGY INC | 1416.00 | 0.00 | 365 |
2001 | EXCO - NORTH COAST ENERGY INC | 1668.00 | 0.00 | 365 |
2002 | EXCO - NORTH COAST ENERGY INC | 1289.00 | 0.00 | 365 |
2003 | EXCO - NORTH COAST ENERGY INC | 1252.00 | 0.00 | 365 |
2004 | EXCO - NORTH COAST ENERGY INC | 1256.00 | 8.00 | 365 |
2005 | EXCO - NORTH COAST ENERGY INC | 1127.00 | 0.00 | 365 |
2006 | EXCO - NORTH COAST ENERGY INC | 1258.00 | 0.00 | 365 |
2007 | EXCO - NORTH COAST ENERGY INC | 1184.00 | 23.00 | 365 |
2008 | EXCO - NORTH COAST ENERGY INC | 1073.00 | 0.00 | 366 |
2009 | EXCO - NORTH COAST ENERGY INC | 487.00 | 0.00 | 365 |
2010 | ENERVEST OPERATING LLC | 713.00 | 0.00 | 365 |
2011 | ENERVEST OPERATING LLC | 660.00 | 0.00 | 0 |
2012 | ENERVEST OPERATING LLC | 348.00 | 0.00 | 366 |
2013 | ENERVEST OPERATING LLC | 615.00 | 0.00 | 365 |
2014 | ENERVEST OPERATING LLC | 282.00 | 54.00 | 365 |
2015 | ENERVEST OPERATING LLC | 65.00 | 0.00 | 38 |
2016 | ENERVEST OPERATING LLC | 581.00 | 0.00 | 164 |
2017 | ENERVEST OPERATING LLC | 443.00 | 0.00 | 226 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-198270213 | 2017-9-21 0:00: | PB | No Violations | 7.00 |
-1999251364 | 2017-10-4 0:00: | FR | No Violations | 1.00 |
-2045680770 | 2017-9-20 0:00: | PB | No Violations | 2.00 |
-576386891 | 2014-9-30 0:00: | PW | No Violations | |
-719662896 | 2017-9-19 0:00: | PB | No Violations | 1.00 |
0198270213 | 2017-09-21 | Plug / Plug Back | No Violations | On the day of my inspection I accompanied ODNR Inspector Austin Gutridge. Please see his comments for a detailed report. Chipco Oil and Gas Well Service had a service rig, cement truck, a bulk cement truck, and a pump truck on location to plug this well. The well was produced from the Clinton Formation with a total depth of 6,036 feet, 8.625 inch diameter surface casing set at 1473 feet, and 4.5 inch diameter production casing set at 6014 feet. The well was producing through perforations in the 4.5 inch diameter production casing from 5946 feet to 5884 feet in depth. Chipco Oil and Gas had 1.5 inch diameter tubing at 6014 feet in depth and set a 400 foot plug consisting of 30 sacks of Class A cement for the bottom plug to cover the Clinton. The 1.5 inch tubing was pulled up to 5110 feet and gas started to flow from the wellbore insinuating that the perforations took a portion of the first plug. So an additional isolation plug was set from 5110 feet to 4844 feet in depth with 20 sacks of Class A cement. The 1.5 inch diameter tubing was tripped out of hole. |
0544758992 | 2017-10-30 | Final Restoration | No Violations | The purpose of my inspection was a status check on a final restoration. All equipment and debris have been removed and the location had been graded. Vegetation has not been established. Once the vegetation is established location will meet the requirements for 1509.072 (B). |
0576386891 | 2014-09-30 | Production Wells | No Violations | My inspection today finds the well is equipped with 4.5 casing and 1.5 tubing with a plunger lift system. The production valves are open and a domestic gas meter is located at the wellhead. The tank battery consists of one 100 barrel tank and a production unit with a meter. |
0719662896 | 2017-09-19 | Plug / Plug Back | No Violations | |
1395565200 | 2049-11-7 0:00: | FR | No Violations | 0.50 |
1483028958 | 2016-12-29 | Production Wells | Violations Noted | The purpose of my inspection today is a status check on a producing well. During my inspection the well was equipped with 8.625 inch diameter surface casing, 4.5 inch diameter production casing, 1.5 inch diameter tubing, and a plunger lift system. The 4.5 inch production casing has a domestic gas line attached with a meter and an open valve. The 4.5 inch casing has a repair clamp right above the 8.625 inch casing head. There is a gas leak right below the repair clamp. The gas is escaping from either the repair clamp on the 4.5 inch casing or from the 8.625 inch casing head. The well shall be equipped so that no gas is allowed to escape into the atmosphere with the exception of gas flares as per 1501:9-9-05 (B). I met in person with the well tender for Enervest, Dave Williams, and I explained the violation and that it needs to be fixed. |
1483130684 | 2016-12-30 | Production Wells | No Violations | During my inspection I witnessed that the well is now equipped to prevent the escaping of gas into the atmosphere. This resolves compliance notice 1483028958. |
1506089437 | 2017-09-21 | Plug / Plug Back | No Violations | During my inspection Chipco Oil and Gas Well Services had a service rig, cement truck, a bulk cement truck, and a pump truck on location to plug this well. The well was produced from the Clinton Formation with a total depth of 6036 feet, 8.625 inch diameter surface casing set at 1473 feet, and 4.5 inch diameter production casing set at 6014 feet. The well was producing through perforations in the 4.5 inch diameter production casing from 5946 feet to 5884 feet in depth. Chipco Oil and Gas had 1.5 inch diameter tubing at 6014 feet in depth and set a 400 foot plug consisting of 30 sacks of Class A cement for the bottom plug to cover the Clinton. The 1.5 inch tubing was pulled up to 5110 feet and gas started to flow from the wellbore insinuating that the perforations took a portion of the first plug. So an addition isolation plug was set from 5110 feet to 4844 feet in depth with 20 sacks of Class A cement. The 1.5 inch diameter tubing was tripped out of hole. The ripping tool was tripped down hole within the 4.5 inch diameter production casing. The casing was ripped at 3950 feet. The formation caved in on the 4.5 inch diameter casing. |
1506345064 | 2017-09-25 | Plug / Plug Back | No Violations | During my inspection the surface plug was completed cured and solid, 3 foot from surface grade. Chipco Oil and Gas Services was rigging down on location and the restoration plan was discussed. Chipco is going to dig down 30 inches around the surface casing, cut off the surface casing, install the identification plate, and restore the location. |
1890746953 | 2017-09-22 | Plug / Plug Back | No Violations | During my inspection I witnessed the 4.5 inch casing pulled up to 1573 feet and the bottom of the surface casing plug was set from 1573 feet to 1373 feet with 60 sacks of Class A cement. |
1999251364 | 2017-10-04 | Final Restoration | No Violations | The purpose of my inspection was a status check on a final restoration. During my inspection the location had been restored and the production equipment had been removed. Location will still need to be seeded to establish vegetation. A follow up inspection will be completed. |
2045680770 | 2017-09-20 | Plug / Plug Back | No Violations | |
544758992 | 2017-10-30 0:00 | FR | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1483028958 | US-OH-113749 | 2017-01-04 | Well insufficiently equipped to prevent escape of oil and gas |
For data sources see[9]