X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-21559

Well Details

Well ID: 34-121-21559
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Center Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: CATER BETTY
License Status: Producing
License Date: 2005-10-26
Spud Date: 1972-10-05
Spud Drilling Contractor:
Final Drill Date: 1972-10-11
Well Total Depth: 5700.00 ft
Configuration: Vertical
Latitude: 39.820000
Longitude: -81.480000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1972-10-05 REV. LOC. 10-4-72
Completed 1972-10-11 REV. LOC. 10-4-72
Reached Total Depth 1972-10-11 REV. LOC. 10-4-72
Completion Report Received 1973-01-30 REV. LOC. 10-4-72
Plugged Back 1977-05-28 REV. LOC. 10-4-72
Change of Owner 2005-10-12 Operator changed from 5417, GAS CORPORATION OF AMER. to 4540, PEOPLES PETROLEUM CORP.
APP 2005-10-26 Proposed Formations:CLINTON, Issued Date:10/26/2005, Expired Date:10/26/2006 6:00:00 AM, Drilling unit acres:97, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2006-03-30 Operator changed from 4540, PEOPLES PETROLEUM CORP. to 1634, NORTHWOOD ENERGY CORP
Construction Permit Expires 2006-10-26 REV. LOC. 10-4-72
Record Last Modified 2017-02-15 REV. LOC. 10-4-72

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5529 5539 0
2006-09-11 5638 5639 0
5529 5539 0
5529 5539 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1720 Bbl 26500 R.P. NSR

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 REDCO INC 0.00 0.00 365
1986 REDCO INC 0.00 0.00 365
1987 REDCO INC 0.00 0.00 365
1989 REDCO INC 0.00 0.00 365
1990 REDCO INC 0.00 0.00 365
1991 REDCO INC 0.00 0.00 365
2005 NORTHWOOD ENERGY CORP 0.00 0.00 0
2006 NORTHWOOD ENERGY CORP 0.00 0.00 0
2007 NORTHWOOD ENERGY CORP 0.00 0.00 0
2008 NORTHWOOD ENERGY CORP 0.00 0.00 0
2009 NORTHWOOD ENERGY CORP 0.00 0.00 0
2010 NORTHWOOD ENERGY CORP 0.00 0.00 0
2011 NORTHWOOD ENERGY CORP 0.00 0.00 0
2012 NORTHWOOD ENERGY CORP 0.00 0.00 0
2013 NORTHWOOD ENERGY CORP 0.00 0.00 0
2014 NORTHWOOD ENERGY CORP 0.00 0.00 0
2015 NORTHWOOD ENERGY CORP 0.00 0.00 0
2016 NORTHWOOD ENERGY CORP 0.00 0.00 0
2017 NORTHWOOD ENERGY CORP 0.00 0.00 0
2018 NORTHWOOD ENERGY CORP 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 REDCO INC Brine 0 365
1986 REDCO INC Brine 0 365
1987 REDCO INC Brine 0 365
1989 REDCO INC Brine 0 365
1990 REDCO INC Brine 0 365
1991 REDCO INC Brine 0 365
2005 NORTHWOOD ENERGY CORP Brine 0 0
2006 NORTHWOOD ENERGY CORP Brine 0 0
2007 NORTHWOOD ENERGY CORP Brine 0 0
2008 NORTHWOOD ENERGY CORP Brine 0 0
2009 NORTHWOOD ENERGY CORP Brine 0 0
2010 NORTHWOOD ENERGY CORP Brine 0 0
2011 NORTHWOOD ENERGY CORP Brine 0
2012 NORTHWOOD ENERGY CORP Brine 0 0
2013 NORTHWOOD ENERGY CORP Brine 0 0
2014 NORTHWOOD ENERGY CORP Brine 0 0
2015 NORTHWOOD ENERGY CORP Brine 140 0
2016 NORTHWOOD ENERGY CORP Brine 45 0
2017 NORTHWOOD ENERGY CORP Brine 0 0
2018 NORTHWOOD ENERGY CORP Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1612181450 2020-1-28 0:00: PW No Violations 0.50
-266376862 2016-1-19 0:00: PW No Violations 0.50
-316538076 2016-5-2 0:00:0 AM No Violations 0.50
-410007364 2016-1-27 0:00: AM No Violations 0.50
-414001073 2017-11-2 0:00: PW No Violations 1.00
-529615275 2015-10-8 0:00: PW No Violations 3.00
-569922016 2017-1-10 0:00: PW No Violations 0.50
0006770022 2015-11-30 Production Wells No Violations This inspection today is to follow up on a compliance notice. This is an idle well. The well head was equipped with 4.5 inch casing and 1.5 inch tubing. The production valves are closed and there has never been any production reported indicating that the well is not in production. Two 210 bbl. tanks, horizontal separator, and a chart meter are on site. The well is incapable of production. Since the compliance notice has been issued there have not been any changes to the well. Well shall be plugged. I will call Northwood Energy to discuss the plugging schedule.
0195108375 2016-04-25 Production Wells No Violations My inspection today is a follow up on a compliance notice -529615275 that was sent to Northwood 10-8-15 for an idle well. The compliance notice stated well shall be plugged within 180 days.180 days have expired. This well is equipped with a plunger lift system. All valves are shut and the well is still idle. Production equipment consist of two 210 bbl. tanks and one horizontal separator.
0266376862 2016-01-19 Production Wells No Violations My inspection today is to follow up on a compliance notice. There have not been any changes since my last inspection. This well is not in production. Northwood Energy will be contacted.
0316538076 2016-05-02 Administrative Inspection No Violations My inspection today is an Administrative Inspection, purpose being a Compliance Notice Follow up. I spoke with Corey McCudden from Northwood Energy explaining to him that this well was given 180 days to reach compliance and those days have expired. Mr. McCudden stated that they are negotiating a new lease with the land owner. Northwood Energy wants to get the well in production. An email was sent to Mr. McCudden following the phone call conversation containing pictures of the well, the date the compliance notice was sent, and the date of the required action. Mr. McCudden will contact me when he obtains more information regarding this well.
0345759505 2017-05-05 Production Wells No Violations The purpose of my inspection was to follow up on compliance notice -529615275. The compliance notice stated violation 1509.12B and the required action stated well shall be plugged. During my inspection the well was equipped with 4.5 inch diameter production casing with a tubing head, 1.5 inch diameter tubing, and a plunger lift system. All valves were in the closed position. No action has been taken to gain compliance and the original violation still exists.
0410007364 2016-01-27 Administrative Inspection No Violations Corey McCudden is ahead of drilling operations and the Geologist for Northwood Energy. I spoke with him on the phone today regarding the compliance notice sent to Northwood. The violation consisted of the well being idle. Corey stated that Northwood was trying to find an existing sales line to get the well hooked into.
0414001073 2017-11-02 Production Wells No Violations The purpose of my inspection was to follow up on compliance notice numbered -529615275. The compliance notice stated violation 1509.12 (B) well shall be plugged. During my inspection the well was equipped with 4.5 inch diameter production casing with a tubing head, 1.5 inch diameter tubing, and a plunger lift system. All production valves were in the closed position. The original violation still exists.
0529615275 2015-10-08 Production Wells Violations Noted During the time of my inspection the well head was equipped with 4.5 inch casing and 1.5 inch tubing. The production valves are closed and there has never been any production reported indicating that the well is not in production. Two 210 bbl. tanks, horizontal separator, and a chart meter are on site. Brush has overtaken the wellhead, separator and the tank ladder. Well shall be plugged. The well owner/operator shall submit a written plugging schedule to Austin Gutridge at 5880 Memory Rd., Zanesville Ohio 43701 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
0569922016 2017-01-10 Production Wells No Violations The purpose of my inspection today is to follow up on a compliance notice # -529615275. During my inspection the well is still shut in and not producing. No action has been taking to bring the well within compliance.
0615787157 2017-07-26 Production Wells No Violations The purpose of my inspection was to follow up on compliance notice numbered -529615275. The compliance notice stated violation 1509.12B and the required action stated well shall be plugged. During my inspection the well was equipped with 4.5 inch diameter production casing with a tubing head, 1.5 inch diameter tubing, and a plunger lift system. All production valves were in the closed position. The original violation still exists. On 7/25/17 I received a phone call from Corey McCudden with Northwood Energy. Mr. McCudden stated that Northwood Energy is searching for an economically efficient sales line for the well to sale natural gas into.
1333367867 2012-04-02 Production Wells No Violations Upon inspection of the well head the following equipment present -4.5 production casing -1.5 tubing -all valves are close and no reported production since 1985, 210 barrel tank and separator on site with no dike-active gas chart or identification present.
134799370 2019-8-1 0:00:0 PW No Violations 0.50
1462214580 2016-05-02 Administrative Inspection No Violations I spoke with Corey McCudden from Northwood Energy discussing the compliance notice on this well. In October of 2015 a compliance notice was issued to Northwood energy for an idle well. Mr. McCudden stated that they are in negotiation with the land owner to get a lease for the well. When Northwood gets a lease the well will be tied in with another well that belongs to Northwood with the permit #3412121571. The compliance notice stated the well shall be plugged within 180 days. Mr. McCudden is aware of the fact the 180 days have expired during April of 2016. No changes have been made, this well is still idle.
1465213821 2016-06-06 Production Wells No Violations The purpose of my inspection today is to follow up on a compliance notice # -529615275. According to Northwood, they are in a negotiation on a lease renewal with the land owners. During my inspection I witnessed the well is shut in and still idle. One 210 bbl. tank has been removed since my last inspection on 4/25/16. The remaining production equipment is one 210 bbl. tank and one horizontal separator. Compliance notice has not been resolved. Follow up inspections will be continued.
1598292984 2020-8-24 0:00: PW No Violations 1.50
195108375 2016-4-25 0:00: PW No Violations 1.00
2009875678 2018-01-23 Production Wells No Violations The purpose of my inspection was to follow up on compliance notice numbered -529615275. During my inspection the well was equipped with a plunger lift system. All production valves were in the closed position. The original violation still exists. Pictures were taken to assist this inspection.
345759505 2017-5-5 0:00:0 PW No Violations 1.00
615787157 2017-7-26 0:00: PW No Violations 2.50
6770022 2015-11-30 0:00 PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0529615275 US-OH-125784 2015-10-13 Well shall be plugged

For data sources see[9]

References