X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-119-28210

Well Details

Well ID: 34-119-28210
Loading map...
Country: United States
State: Ohio
County: Muskingum
Municipality: Salt Creek Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: MANN ED
License Status: Producing
License Date: 1999-02-02
Spud Date: 1999-02-04
Spud Drilling Contractor: PROFESSIONAL WELL SVC-PWS
Final Drill Date: 1999-02-10
Well Total Depth: 4245.00 ft
Configuration: Vertical
Latitude: 39.910000
Longitude: -81.890000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1999-02-02 Proposed Formations:CLINTON, Issued Date:2/2/99, Expired Date:2/2/00 6:00:00 AM, Drilling unit acres:285.136, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 1999-02-04 RBDMS Rec
Completed 1999-02-10 RBDMS Rec
Reached Total Depth 1999-02-10 RBDMS Rec
Completion Report Received 1999-04-30 RBDMS Rec
Construction Permit Expires 2000-02-02 RBDMS Rec
Change of Owner 2014-02-06 Operator changed from 79, OXFORD OIL to 9216, ECLIPSE RESOURCES-OHIO LLC
Change of Owner 2016-08-02 Operator changed from 9216, ECLIPSE RESOURCES-OHIO LLC to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2016-08-04 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-08-04 4031 4158 16
4031 4158 16
4031 4158 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 509 Bbl 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1999 OXFORD OIL 870.00 210.00 365
2000 OXFORD OIL 895.00 173.00 0
2001 OXFORD OIL 947.00 126.00 365
2002 OXFORD OIL 849.00 99.00 365
2003 OXFORD OIL 952.00 85.00 365
2004 OXFORD OIL 657.00 82.00 365
2005 OXFORD OIL 754.00 47.00 365
2006 OXFORD OIL 670.00 36.00 365
2007 OXFORD OIL 571.00 44.00 365
2008 OXFORD OIL 887.00 97.00 0
2009 OXFORD OIL 1184.00 164.00 0
2010 OXFORD OIL 1268.00 151.00 365
2011 OXFORD OIL 1075.00 134.00 0
2012 OXFORD OIL 948.00 132.00 0
2013 ECLIPSE RESOURCES-OHIO LLC 572.00 49.00 365
2014 ECLIPSE RESOURCES-OHIO LLC 576.00 79.00 365
2015 ECLIPSE RESOURCES-OHIO LLC 0.00 0.00 365
2016 ECLIPSE RESOURCES-OHIO LLC 0.00 0.00 365
2017 M & R INVESTMENTS OHIO LLC 368.00 0.00 365
2018 M & R INVESTMENTS OHIO LLC 16.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1999 OXFORD OIL Brine 47 365
2000 OXFORD OIL Brine 70
2001 OXFORD OIL Brine 135 365
2002 OXFORD OIL Brine 138 365
2003 OXFORD OIL Brine 136 365
2004 OXFORD OIL Brine 141 365
2005 OXFORD OIL Brine 158 365
2006 OXFORD OIL Brine 37 365
2007 OXFORD OIL Brine 28 365
2008 OXFORD OIL Brine 104
2009 OXFORD OIL Brine 83
2010 OXFORD OIL Brine 72 365
2011 OXFORD OIL Brine 80
2012 OXFORD OIL Brine 57
2013 ECLIPSE RESOURCES-OHIO LLC Brine 194 365
2014 ECLIPSE RESOURCES-OHIO LLC Brine 21 365
2015 ECLIPSE RESOURCES-OHIO LLC Brine 0 365
2016 M & R INVESTMENTS OHIO LLC Brine 0 365
2017 M & R INVESTMENTS OHIO LLC Brine 0 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1991626290 2004-3-10 0:00: PW No Violations
-2034089050 2019-5-30 0:00: PW No Violations 0.70
-932331493 2020-5-19 0:00: PW No Violations 0.20
0429326966 2018-01-25 Production Wells Violations Noted On the day of my inspection the well is not producing. The electric pole has been cut off and is lying on the unit. There is a pumping unit and a tubing head. The tubing valve is closed and the casing valve is open. There is a shared tank which consists of [1]210 barrel steel tank and [1]1100 gallon plastic tank with 800 gallon of fluid. There are [2] vertical separators that are on the production equipment site. All are enclosed within an earthen impoundment. There is an identification posted at the tank but not the well.
1144511711 2018-03-14 Production Wells No Violations The inspection is due to a compliance notice follow-up to number 429326966 [ General Safety, Identification]. I called Jody Jasper to on getting the power pole reset so the electric can be hooked up. On the day of my inspection the well is not producing. The electric pole has been moved off the unit and is lying on the ground. There is a pumping unit and a tubing head. The tubing valve is closed, and the casing valve is open. There is a shared tank which consists of [1]210-barrel steel tank and [1]1100-gallon plastic tank. There are [2] vertical separators that are on the production equipment site. All are enclosed within an earthen impoundment. There is an identification posted at the tank but not the well.
1518020947 2018-02-07 Production Wells No Violations The purpose of the inspection is due to a Compliance Notice Follow up to number 429326966. On the day of my inspection there was no change at the well. The identification was not updated from Eclipse to the Current Company. The power pole was still lying on the unit with the cut wires lying on the ground. Pictures were taken on the day of the inspection.
1954078898 2008-05-09 Production Wells No Violations Producing, no problems noted.
1991626290 2004-03-10 Production Wells No Violations
2034089050 2019-05-30 Production Wells No Violations The inspection is due to a Compliance Notice follow-up to number 429326966 [ General Safety]. I called Matt Kapunis the field Supervisor on getting the power pole reset so the electric can be hooked up. The electric pole has been moved off the unit and is lying on the ground. There is a pumping unit and a tubing head. The tubing valve is closed, and the casing valve is open. There is a shared tank which consists of [1]210-barrel steel tank and [1]1100-gallon plastic tank. There are [2] vertical separators that are on the production equipment site. All are enclosed within an earthen impoundment. There is an identification posted at the tank and at the well.
429326966 2018-1-25 0:00: PW No Violations
iDIAN00186 1999-09-21 Preliminary Restoration No Violations
iDIAN001867 1999-9-21 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0429326966 US-OH-124589 2018-02-06 General Safety
0429326966 US-OH-124590 2018-02-06 Failure to legibly identify well

For data sources see[9]

References