If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-115-24603 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.74,"lon":-82.04,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Morgan | |
Municipality: York Township | |
Operator Name: TEMPLE OIL & GAS CO | |
Well Pad ID: | |
Farm/Lease Name: HAMILTON JIM | |
License Status: Producing | |
License Date: 2007-08-23 | |
Spud Date: 2008-01-28 | |
Spud Drilling Contractor: TEMPLE OIL & GAS | |
Final Drill Date: 2008-02-22 | |
Well Total Depth: 1223.00 ft | |
Configuration: Vertical | |
Latitude: 39.740000 | |
Longitude: -82.040000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-08-23 | Proposed Formations:BEREA, Issued Date:8/23/2007, Expired Date:8/22/2008 6:00:00 AM, Drilling unit acres:35, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-02-22 | |
Construction Permit Expires | 2008-08-22 | |
Completion Report Received | 2008-10-16 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-12-03 | 1181 | 1199 | 20 |
1181 | 1199 | 20 | |
1181 | 1199 | 20 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 300 Gal | 11000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | TEMPLE OIL & GAS CO | 198.00 | 0.00 | 365 |
2009 | TEMPLE OIL & GAS CO | 1380.00 | 0.00 | 261 |
2010 | TEMPLE OIL & GAS CO | 951.00 | 0.00 | 313 |
2011 | TEMPLE OIL & GAS CO | 382.00 | 53.00 | 365 |
2012 | TEMPLE OIL & GAS CO | 492.00 | 0.00 | 366 |
2013 | TEMPLE OIL & GAS CO | 660.00 | 0.00 | 365 |
2014 | TEMPLE OIL & GAS CO | 170.00 | 0.00 | 365 |
2015 | TEMPLE OIL & GAS CO | 453.00 | 0.00 | 365 |
2016 | TEMPLE OIL & GAS CO | 735.00 | 0.00 | 365 |
2017 | TEMPLE OIL & GAS CO | 415.00 | 0.00 | 365 |
2018 | TEMPLE OIL & GAS CO | 421.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2009 | TEMPLE OIL & GAS CO | Brine | 60 | 261 |
2010 | TEMPLE OIL & GAS CO | Brine | 0 | 313 |
2011 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2012 | TEMPLE OIL & GAS CO | Brine | 0 | 366 |
2013 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2014 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2015 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2016 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2017 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2018 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-59773399 | 2009-4-6 0:00:0 | PL | No Violations | |
0059773399 | 2009-04-06 | Preliminary Restoration | No Violations | Restoration meets 1509.072(A) requirements. May need some remedial work later in summer. |
0806923804 | 2017-03-03 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a pumping unit, a 4 1/2 inch diameter wellhead, and a 1 1/2 inch diameter production tubing. The valves on the wellhead are open at the time of inspection. The tank battery for this well is equipped with a 100 barrel steel tank, and proper identification on the tank. There are no issues to report at this time and the well is currently in production at the time of inspection. |
806923804 | 2017-3-3 0:00:0 | PW | No Violations | 1.00 |
For data sources see[9]