X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-115-24271

Well Details

Well ID: 34-115-24271
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Union Township
Operator Name: ALTIER BROTHERS INC
Well Pad ID:
Farm/Lease Name: CHAPPELEAR UNIT
License Status: Final Restoration
License Date: 2014-05-07
Spud Date: 1992-07-02
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1992-07-07
Well Total Depth: 4370.00 ft
Configuration: Vertical
Latitude: 39.580000
Longitude: -82.000000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1992-06-04 Issued Date 6/4/92 Expired Date 6/4/93 Acres 0130331 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04370 Proposed Drill Depth 04370
Original Spud 1992-07-02 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014
Completed 1992-07-07 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014
Reached Total Depth 1992-07-07 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014
CO 1992-08-21 133 QUAKER STATE OIL REF CORP GeoDate 6/4/92
Completion Report Received 1992-11-13 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 6/4/92
Annular Disposal Well 1997-08-28
Change of Owner 2002-08-09 Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC
Change of Owner 2010-12-27 Operator changed from 1966, PETROX, INC to 1429, ALTIER BROTHERS INC
Revocation 2013-08-08 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014
APP 2014-05-07 Proposed Formations:CLINTON, Issued Date:5/7/2014, Expired Date:5/6/2016 12:00:00 PM, Drilling unit acres:130.331, Proposed Well Type:TAAD, Proposed Well Class:
Plugged/Abandoned 2014-10-01 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014
Last Compliance Report 2014-11-03 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014
Construction Permit Expires 2016-05-06 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014
Record Last Modified 2017-02-15 UPDATED TO PA WITNESSED BY JAKE GLASCOCK 10/01/2014

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-02-27 4154 4177 18
4154 4177 18
4154 4177 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 119000 Gal 0 TREATED AT 37.7 BPM

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 QUAKER STATE OIL REF CORP 23.00 0.00 365
1993 QUAKER STATE OIL REF CORP 29965.00 0.00 365
1994 QUAKER STATE OIL REF CORP 14534.00 0.00 365
1995 BELDEN & BLAKE CORPORATION 5784.00 0.00 130
1996 BELDEN & BLAKE CORPORATION 10371.00 53.00 326
1997 BELDEN & BLAKE CORPORATION 5109.00 0.00 306
1998 BELDEN & BLAKE CORPORATION 5468.00 0.00 350
1999 BELDEN & BLAKE CORPORATION 4302.00 0.00 345
2000 BELDEN & BLAKE CORPORATION 1932.00 0.00 320
2001 BELDEN & BLAKE CORPORATION 1577.00 0.00 256
2002 PETROX, INC 1421.00 33.00 59
2003 PETROX, INC 2232.00 0.00 365
2004 PETROX, INC 1869.00 0.00 365
2005 PETROX, INC 1480.00 0.00 365
2006 PETROX, INC 1723.00 0.00 365
2007 PETROX, INC 84.00 0.00 31
2008 PETROX, INC 79.00 0.00 88
2009 PETROX, INC 1673.00 0.00 365
2010 PETROX, INC 274.00 0.00 90
2014 ALTIER BROTHERS INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 QUAKER STATE OIL REF CORP Brine 1188 365
1993 QUAKER STATE OIL REF CORP Brine 2792 365
1994 QUAKER STATE OIL REF CORP Brine 2519 365
1995 BELDEN & BLAKE CORPORATION Brine 0 130
1996 BELDEN & BLAKE CORPORATION Brine 0 326
1997 BELDEN & BLAKE CORPORATION Brine 0 306
1998 BELDEN & BLAKE CORPORATION Brine 0 350
1999 BELDEN & BLAKE CORPORATION Brine 0 345
2000 BELDEN & BLAKE CORPORATION Brine 24 320
2001 BELDEN & BLAKE CORPORATION Brine 0 256
2002 BELDEN & BLAKE CORPORATION Brine 15 207
2003 PETROX, INC Brine 0 365
2004 PETROX, INC Brine 0 365
2005 PETROX, INC Brine 0 365
2006 PETROX, INC Brine 0 365
2007 PETROX, INC Brine 31
2008 PETROX, INC Brine 0 88
2009 PETROX, INC Brine 0 365
2010 PETROX, INC Brine 0 90
2014 ALTIER BROTHERS INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1044367607 2013-11-6 0:00: AD No Violations 2.00
-1555745324 2014-10-1 0:00: FR No Violations
-2053416436 2014-3-25 0:00: PW No Violations 1.00
-228033053 2003-7-11 0:00: PW No Violations
0019680527 2002-11-05 Annular Disposal No Violations CHECK WELL FOR A.D. NOT BEING USED FOR A.D.
0028384212 2003-10-17 Production Wells No Violations no violations noted on day of my inspection pump jack was working on day of my inspection.
0228033053 2003-07-11 Production Wells No Violations no violations noted,all production equiptment in place
0571022418 2014-02-13 Production Wells No Violations Compliance Action Follow-up -1044367607: The AD has been disconnected at the wellhead and to the tank. The well is still shut in and the chart on the meter is dated 10/2013. There is no motor on the pumpjack. The dike is covered with ice and snow so I will come back after a change in the weather to follow up on the contamination issues.
0654206761 2014-08-21 Plug / Plug Back No Violations I covered this plug job for inspector Jake Glascock. Altiers was on plugging the well. The plug report was done by inspector Glascock.
1044367607 2013-11-06 Annular Disposal Violations Noted This is an annular disposal inspection as part of a request from Columbus DOGRM. There is one 100bbl tank with a knockout and a separator in the tank battery. The annular disposal appears to be hooked up with an open valve, however there is another disconnected pipe sticking up on the backside of the wellhead which could be the actual line. There is no motor on the pumpjack. The dike does have contamination and several small line leaks. There is standing water on one side of the dike which Quantab (low range) tested >700ppm of chlorides. I called the operator and he stated the well tender had disconnected the annular disposal and are in the process of getting the well back into commercial production. Their motor was recently stolen and they just bought a new one. They will repair any leaks and cleanup any contamination. The operator stated the well tender Dave Paul will call me to discuss the annular disposal work. 11/8/2013: Tim Altier stated the AD was only disconnected at the tank battery. They called Columbus and plan on performing a mechanical integrity test on wellhead in order to maintain annular disposal opportunity. If this does not work for them then they will file for a plug permit.
1071570178 2003-12-15 Production Wells No Violations Pump jack stroking no violations noted today.
1077401155 2014-08-21 Plug / Plug Back No Violations I was on location to witness Formation set the surface casing plug using 55 sacks of Class A cement. Fluid level was around 275 so they set a brush and stone plug. Formation then set a 200 surface plug using 47 sacks of cement. The cement stayed at the surface.
1214651737 2008-06-27 Annular Disposal No Violations On site to witness MIT Test,Ohio Pump of Logan preformed test, worker pressured up on annulus to 445 psi with Nitrogen and we monitored pressure for 1 hr. no decline in pressure test passed,called company rep Jeff Marshall and requested cleanup around wellhead before placing well back into production he stated he would call after cleanup was done so I could inspect site for compliance.
1385392053 2013-11-25 Annular Disposal No Violations Compliance Action Follow-up -1044367607: There has been no resolution to any of the issues. Some lime was thrown down in various places in the dike but no contamination has been removed from area. AD is still hooked up at wellhead.
1408562173 2014-08-20 Plug / Plug Back No Violations I was on location to witness Altier Brothers and Formation set a 400 bottom hole plug from 3800-4200 using 30 sacks of Class A cement.
1555745324 2014-10-01 Final Restoration No Violations Location meets 1509.072 final restoration requirements.
1692745290 2014-04-22 Production Wells No Violations Compliance Action Follow-up -1044367607: There is still contamination in the dike. Benny stated that he will have the dike equipment removed and cleaned up on Thursday.
19680527 2002-11-5 0:00: AD No Violations
2053416436 2014-03-25 Production Wells No Violations Compliance Action Follow-up -1044367607: The well is currently shut in and there is an old chart in the meter box. There is no motor on the pumpjack and there is still contamination in the dike. I talked with the bookkeeper, Ernie, and stated they plan on plugging the well and will be sending in the plug permit this week. I told him about the dike issues and he said he would relay the information to Benny Altier. Benny called back and stated he would take care of the issues.
28384212 2003-10-17 0:00 PW No Violations
571022418 2014-2-13 0:00: PW No Violations 1.00
654206761 2014-8-21 0:00: PB No Violations 8.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1044367607 US-OH-100692 2014-09-05 Failure to keep SPCC dike/pit free of brine and other wastes

For data sources see[9]