If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-115-24261 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.57,"lon":-81.93,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Morgan | |
Municipality: Union Township | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: JANES MYRON & MARY HW 90-17 | |
License Status: Producing | |
License Date: 1992-04-27 | |
Spud Date: 1992-05-22 | |
Spud Drilling Contractor: DON WOOD | |
Final Drill Date: 1992-08-10 | |
Well Total Depth: 1420.00 ft | |
Configuration: Vertical | |
Latitude: 39.570000 | |
Longitude: -81.930000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1992-04-27 | Issued Date 4/27/92 Expired Date 4/27/93 Acres 0010000 Tool Type CT Proposed Formation BEREA Proposed Depth 01420 Proposed Drill Depth 01420 |
Original Spud | 1992-05-06 | |
Completed | 1992-08-10 | |
Reached Total Depth | 1992-08-10 | |
CO | 1992-09-10 | 1 HOPEWELL OIL & GAS DEV CO GeoDate 4/27/92 |
Completion Report Received | 1992-10-19 | |
Construction Permit Expires | 1993-04-27 | |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 1368 | 1370 | 2 |
1358 | 1375 | 0 | |
1997-06-29 | 1358 | 1375 | 0 |
1368 | 1370 | 2 | |
1358 | 1375 | 0 | |
2006-09-11 | 1424 | 1426 | 2 |
2006-09-11 | 1420 | 1422 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 500 Gal | 19000 | FRAC...WATER/SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000011735 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 6/19/96 INSPECTOR MIKE KAVAGE DATE 06/1919/96 DATA FROM OLD VAX INFO | |
0162126762 | 2016-03-04 | Production Wells | No Violations | On my inspection today I found this well to have no issues to report at the time of inspection. |
1013070455 | 2013-07-18 | Production Wells | Violations Noted | This was a tank battery inspection. There are two 100 bbl tanks and the tank on the right is leaking from the bottom. There are signs of a scald area all around the tanks and there is no dike. There is a current chart in the meter which is adjacent to the tanks. I called and talked to Howard Harrop and he stated he would remove the leaking tank and clean up area. He will also build up a dike when they are in that area with a swab rig in the next few weeks. |
11735 | PL | No Violations | ||
1377797330 | 2013-08-29 | Production Wells | No Violations | Compliance Action Follow-up 1013070455: Well is in compliance. There are no issues to report at this time. |
162126762 | 2016-3-4 0:00:0 | PW | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1013070455 | US-OH-100474 | 2013-10-22 | No SPCC dike/or failure to keep dike free of water or oil | |
1013070455 | US-OH-100475 | 2013-10-22 | Equipment pressure rated below operating pressure |
For data sources see[9]