Well Details

Well ID: 34-115-24256
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Union Township
Operator Name: WILSON GERTRUDE
Well Pad ID:
Farm/Lease Name: WILSON IVAN
License Status: Domestic Well
License Date: 1997-06-13
Spud Date: 1992-03-09
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1992-03-13
Well Total Depth: 4459.00 ft
Configuration: Vertical
Latitude: 39.630000
Longitude: -81.920000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1992-02-24 Issued Date 2/24/92 Expired Date Acres 0112000 Tool Type RTA Proposed Formation CLINTON Proposed Depth Proposed Drill Depth
Original Spud 1992-03-09
Completed 1992-03-13
Reached Total Depth 1992-03-13
Completion Report Received 1992-04-03
CO 1992-04-06 1675 KILBARGER EDWARD OR ANN GeoDate 2/24/92
Construction Permit Expires 1993-02-23
CO 1997-06-13 1675 KILBARGER EDWARD OR ANN GeoDt 6/13/97
Unknown 1997-06-13 Issued Date 6/13/97 Expired Date 6/13/98 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Change of Owner 2000-01-10 Operator changed from 1675, KILBARGER EDWARD OR ANN to 4926, WILSON J L
Change of Owner 2001-06-12 Operator changed from 4926, WILSON J L to 6997, WILSON GERTRUDE
Last Compliance Report 2016-11-10
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4268 4336 0
4268 4336 0
2006-09-11 4269 4276 32
4269 4276 32
4268 4336 0
2006-09-11 4305 4309 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 FRAC'D...WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 KILBARGER INVESTMENTS INC 2929.00 148.00 365
1993 KILBARGER INVESTMENTS INC 1987.00 207.00 365
1994 KILBARGER INVESTMENTS INC 1057.00 135.00 365
1995 KILBARGER INVESTMENTS INC 780.00 132.00 365
1996 KILBARGER INVESTMENTS INC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 KILBARGER INVESTMENTS INC Brine 600 365
1993 KILBARGER INVESTMENTS INC Brine 400 365
1994 KILBARGER INVESTMENTS INC Brine 300 365
1995 KILBARGER INVESTMENTS INC Brine 1000 365
1996 KILBARGER INVESTMENTS INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1642941279 2011-9-7 0:00:0 PW No Violations 0.50
-384463173 2016-9-21 0:00: TD No Violations
-862865589 2008-9-23 0:00: AD No Violations
0000002302 Preliminary Restoration No Violations PASSED Y WITNESSED 5/28/92 INSPECTOR DAN GOINS DATE 05/2819/92 DATA FROM OLD VAX INFO
001289i324 2002-04-23 Annular Disposal No Violations T.A.A.D WELL, DOMESTIC WELL
0157166437 2015-05-20 Production Wells No Violations This well is a domestic well. The well has a pumping unit on it with rods and tubing in it. The valves are open making the well capable of providing house gas. There are no violations at this time.
0384463173 2016-09-21 Temporary Abandoned Annular Disposal No Violations This inspection was conducted as a TAAD status check. It appears that the owner is getting gas off of the 8 casing. A 2 line was observed coming from the 8 and connected to the separator. Well does not appear to be hooked up for annular disposal use. A business card was left at the well for the owner to call. Time of inspection: 9:05 AM.
0862865589 2008-09-23 Annular Disposal No Violations A.D. not hooked up well is equipped with pumping unit with motor missing and 1-100 bbl tank,well is being used for domestic purposes only.
1289i324 2002-4-23 0:00: AD No Violations
157166437 2015-5-20 0:00: PW No Violations 1.00
1642941279 2011-09-07 Production Wells No Violations Inspection this day found well with operational pumpjack with valves open. Tank battery very overgrown, could not get close, no IDs found. This is a landowner well.
1754649108 2016-09-08 Temporary Abandoned Annular Disposal No Violations This inspection was conducted as a TAAD status check. The inspection revealed a 2 line connected to the 8 diameter casing. A valve on the 2 line was in the closed position. The line ran towards the direction of the tank battery and was buried once it went past the pumping unit. It did not appear to be connected to the tank battery. The tank battery consists of (2) 100 barrel tanks and a separator. Identification was not posted at the well or tank battery. A flow line leak was observed between the well and the tank battery. It was not leaking during inspection. The well owner will be contacted regarding this inspection. Time of inspection: 1:30 PM.
2302 PL No Violations

For data sources see[9]