X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-115-23765

Well Details

Well ID: 34-115-23765
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Windsor Township
Operator Name: GENESIS RESOURCES LLC
Well Pad ID:
Farm/Lease Name: CHIPPS UNIT
License Status: Producing
License Date: 1984-12-26
Spud Date: 1985-02-18
Spud Drilling Contractor: PERKINS DRLG
Final Drill Date: 1985-02-21
Well Total Depth: 5253.00 ft
Configuration: Vertical
Latitude: 39.590000
Longitude: -81.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-12-26 471 EAGLE MOUNTAIN ENERGY GeoDate 12/26/84
Oil and Gas 1984-12-26 Issued Date 12/26/84 Expired Date 6/24/85 Acres 0160000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05253 Proposed Drill Depth 05253
Original Spud 1985-02-18
Completed 1985-02-21
Reached Total Depth 1985-02-21
Completion Report Received 1985-03-29
Construction Permit Expires 1985-06-24
CO 1996-07-24 4801 BANCEQUITY PETROLEUM CORP GeoDate 12/26/84
Last Compliance Report 2016-11-10
Change of Owner 2018-05-04 Operator changed from 4801, BANCEQUITY PETROLEUM CORP to 9086, GENESIS RESOURCES LLC
Record Last Modified 2018-05-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4948 5036 0
4948 5036 0
2006-09-11 4990 5092 43
4990 5092 43
4948 5036 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 720 Mscf 0
H2O 0 300 Bbl 48000 FRAC: H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 EAGLE MOUNTAIN ENERGY 20287.00 0.00 250
1986 EAGLE MOUNTAIN ENERGY 14523.00 0.00 365
1987 EAGLE MOUNTAIN ENERGY 12928.00 0.00 365
1988 EAGLE MOUNTAIN ENERGY 9545.00 0.00 365
1989 SCION ENERGY INC 5997.00 0.00 365
1990 EAGLE MOUNTAIN ENERGY 4455.00 0.00 365
1991 EAGLE MOUNTAIN ENERGY 4010.00 0.00 365
1993 EAGLE MOUNTAIN ENERGY 2049.00 0.00 365
1994 EAGLE MOUNTAIN ENERGY 1334.00 0.00 365
1996 BANCEQUITY PETROLEUM CORPORATI 1450.00 0.00 365
1997 BANCEQUITY PETROLEUM CORPORATI 1450.00 0.00 365
1998 BANCEQUITY PETROLEUM CORPORATI 964.00 0.00 365
2000 BANCEQUITY PETROLEUM CORPORATI 1045.00 0.00 365
2001 BANCEQUITY PETROLEUM CORPORATI 998.00 0.00 365
2002 BANCEQUITY PETROLEUM CORPORATI 785.00 0.00 365
2003 BANCEQUITY PETROLEUM CORPORATI 809.00 0.00 365
2004 BANCEQUITY PETROLEUM CORPORATI 430.00 0.00 365
2005 BANCEQUITY PETROLEUM CORPORATI 1189.00 198.00 365
2006 BANCEQUITY PETROLEUM CORPORATI 899.00 0.00 365
2007 BANCEQUITY PETROLEUM CORPORATI 1099.00 0.00 365
2008 BANCEQUITY PETROLEUM CORPORATI 1229.00 0.00 365
2009 BANCEQUITY PETROLEUM CORPORATI 925.00 0.00 365
2010 BANCEQUITY PETROLEUM CORPORATI 1001.00 0.00 365
2011 BANCEQUITY PETROLEUM CORPORATI 830.00 0.00 0
2012 BANCEQUITY PETROLEUM CORPORATI 835.00 0.00 366
2013 BANCEQUITY PETROLEUM CORPORATI 750.00 0.00 365
2014 BANCEQUITY PETROLEUM CORPORATI 680.00 0.00 365
2015 BANCEQUITY PETROLEUM CORPORATI 565.00 0.00 365
2016 BANCEQUITY PETROLEUM CORPORATI 484.00 0.00 365
2017 BANCEQUITY PETROLEUM CORPORATI 496.00 0.00 365
2018 BANCEQUITY PETROLEUM CORPORATI 274.00 0.00 120

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 EAGLE MOUNTAIN ENERGY Brine 107 250
1986 EAGLE MOUNTAIN ENERGY Brine 94 365
1987 EAGLE MOUNTAIN ENERGY Brine 48 365
1988 EAGLE MOUNTAIN ENERGY Brine 70 365
1989 SCION ENERGY INC Brine 16 365
1990 EAGLE MOUNTAIN ENERGY Brine 0 365
1991 EAGLE MOUNTAIN ENERGY Brine 6 365
1993 EAGLE MOUNTAIN ENERGY Brine 0 365
1994 EAGLE MOUNTAIN ENERGY Brine 186 365
1996 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
1997 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
1998 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2000 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2001 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2002 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2003 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2004 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2005 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2006 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2007 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2008 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2009 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2010 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2011 BANCEQUITY PETROLEUM CORPORATI Brine 0
2012 BANCEQUITY PETROLEUM CORPORATI Brine 0 366
2013 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2014 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2015 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2016 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2017 BANCEQUITY PETROLEUM CORPORATI Brine 0 365
2018 BANCEQUITY PETROLEUM CORPORATI Brine 0 120

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1401611569 2020-6-2 0:00:0 PW No Violations 0.50
-153589405 2019-2-19 0:00: PW No Violations 0.50
-1720804251 2016-9-7 0:00:0 TD No Violations 1.00
-1738049493 2017-3-1 0:00:0 PW No Violations 3.00
0000PL9442 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0001289i89 2002-02-05 Production Wells No Violations T.A.A.D WELL
0011748378 2019-01-16 Production Wells Violations Noted I was on location today to do a field inspection on this well. During my inspection I found the identification for this well is incorrect. The owner has changed and needs to be updated on the identification posted for this well. The well is required to have legible identification posted either at the well or at the production tank. If there is more than one well producing into the same production tank the identification is required to be at both the well and the production tank. The identification must have the following on it. The owner, lease name, well number, permit number, county and emergency contact number.
0016510776 2011-08-29 Production Wells No Violations Inspection this day found well producing with rabbit - tank has good IDs, separator & well also, current chart in meter. Pumper on location.
0153589405 2019-02-19 Production Wells No Violations I was on location today to do a follow-up inspection on this well for the identification for it. At this time the identification has not been fixed or corrected. The well is still currently in violation.
0236921828 2015-03-06 Production Wells No Violations There are no issues to report at this time.
0393833714 2019-05-06 Production Wells No Violations I am back on location today to follow-up on the identification on this well. The identification has still not been fixed. I will contact the company again about the issue.
11748378 2019-1-16 0:00: PW No Violations 0.50
1210622120 2008-05-12 Annular Disposal No Violations A.D. not being used,well is equipped with production casing and 1.5tubing and separator&2-100 bbl tanks in need of proper dike construction.
1289i89 2002-2-5 0:00:0 PW No Violations
1387288670 2019-6-18 0:00: PW No Violations 0.50
1553772995 2019-03-28 Production Wells No Violations I was back on location today to follow-up on the identification for this well. The identification has still not been corrected to the new owner. I will reach out to the company again to let them know it still needs done.
16510776 2011-8-29 0:00: PW No Violations 0.50
1720804251 2016-09-07 Temporary Abandoned Annular Disposal No Violations The inspection today revealed that this well is capable of production through the 4 1/2 inch diameter casing. The annular disposal is not hooked up at the time of inspection and there are no issues to report at this time.
1738049493 2017-03-01 Production Wells No Violations The inspection this day revealed that this well is equipped with a plunger lift system, a 4 1/2 inch diameter wellhead, and 1 1/2 inch diameter production tubing. The valves on the wellhead were closed at the time of inspection but the valve leading from the production tubing was open at the time of inspection. The tank battery is equipped with a 100 barrel steel tank and a horizontal separator with a current chart in it. There are no issues to report at this time and this well is in production at the time of inspection.
236921828 2015-3-6 0:00:0 PW No Violations 0.30
393833714 2019-5-6 0:00:0 PW No Violations 0.50
632690609 2019-7-9 0:00:0 PW No Violations 0.50
PL9442 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0011748378 US-OH-104620 2019-01-17 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]

References