34-111-63116

Well Details

Well ID: 34-111-63116
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Malaga Township
Operator Name: C G O INC
Well Pad ID:
Farm/Lease Name: ACKERMAN BEN P
License Status: Final Restoration
License Date: 2015-12-23
Spud Date: 1948-08-20
Spud Drilling Contractor:
Final Drill Date: 1948-09-26
Well Total Depth: 1889.00 ft
Configuration: Vertical
Latitude: 39.820000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Reached Total Depth 1948-09-26 DEEPENED FROM 1080' IN MAXTON TO 1889' IN BEREA GMM WELL WAS CHANGED TO PA STATUS BASED ON PLUG REPORT
Completion Report Received 1948-11-03 DEEPENED FROM 1080' IN MAXTON TO 1889' IN BEREA GMM WELL WAS CHANGED TO PA STATUS BASED ON PLUG REPORT
APP 2015-12-23 Proposed Formations:BEREA, Issued Date:12/23/2015, Expired Date:12/22/2017 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2016-01-06 DEEPENED FROM 1080' IN MAXTON TO 1889' IN BEREA GMM WELL WAS CHANGED TO PA STATUS BASED ON PLUG REPORT
Record Last Modified 2017-02-15 DEEPENED FROM 1080' IN MAXTON TO 1889' IN BEREA GMM WELL WAS CHANGED TO PA STATUS BASED ON PLUG REPORT
Construction Permit Expires 2017-12-22 DEEPENED FROM 1080' IN MAXTON TO 1889' IN BEREA GMM WELL WAS CHANGED TO PA STATUS BASED ON PLUG REPORT

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1999 C G O INC 9.00 0.00 365
2000 C G O INC 31.00 0.00 365
2001 C G O INC 40.00 0.00 365
2002 C G O INC 23.00 0.00 365
2003 C G O INC 47.00 0.00 365
2004 C G O INC 28.00 0.00 365
2005 C G O INC 32.00 0.00 365
2006 C G O INC 16.00 0.00 365
2007 C G O INC 29.00 0.00 365
2008 C G O INC 33.00 0.00 365
2009 C G O INC 22.00 0.00 365
2010 C G O INC 201.00 0.00 365
2011 C G O INC 114.00 0.00 365
2015 C G O INC 75.00 0.00 290
2016 C G O INC 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1999 C G O INC Brine 0 365
2000 C G O INC Brine 0 365
2001 C G O INC Brine 0 365
2002 C G O INC Brine 0 365
2003 C G O INC Brine 0 365
2004 C G O INC Brine 0 365
2005 C G O INC Brine 0 365
2006 C G O INC Brine 0 365
2007 C G O INC Brine 0 365
2008 C G O INC Brine 0 365
2009 C G O INC Brine 0 365
2010 C G O INC Brine 0 365
2011 C G O INC Brine 0 365
2015 C G O INC Brine 0 290
2016 C G O INC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1136548004 2010-3-16 0:00: PW No Violations
-127234896 2015-12-31 0:00 PW No Violations
-1464392574 2012-2-13 0:00: PW No Violations 0.50
-1487862935 2016-1-6 0:00:0 PB No Violations
-1525810583 2016-9-22 0:00: FR No Violations 1.00
-389981594 2012-2-13 0:00: PW No Violations 0.50
-508185111 2016-1-5 0:00:0 PB No Violations
-542156170 2016-9-22 0:00: FR No Violations 1.00
0078948384 2010-10-29 Production Wells No Violations On day of inspection well is capable and id is present and production has been filed.NOV is resolved.
0127234896 2015-12-31 Production Wells No Violations On the day of my inspection I witnessed Harmon Well Service and Timco Inc. was onsite. Timco tripped inside the 2 inch tubing and found total depth at 1885 feet and open hole packer was found set from 1820 feet to 1818 feet. HWS will trip 1 inch tubing in the wellbore today with plans to commence plugging on Tuesday.
0389981594 2012-02-13 Production Wells Violations Noted FOLLOW UP TO NOV # -1464392574 I received a call from John Ackerman who is concerned about the production of this well. Production has not been submitted for two years. The production that is submitted shows a history of production under the minimum standard. Mr. Ackerman states he has requested a report of production and has not received one in two years. This well is owned by C G O INC. Well shall be plugged or application shall be submitted for temporary inactive status.
0508185111 2016-01-05 Plug / Plug Back No Violations On 12/31/2015 the well was logged by Timco Inc with a total depth recorded of 1,885 a packer is set on the 2 tubing and was marked at 1,820, 2 holes were perforated in the 2 tubing below the packer and 1 tubing was ran into the well bore. 01/05/2016 A bottom plug was set through the 1 tubing set at 1864 and a 11 sack plug was set to isolate the area below the packer set at 1,820, the 1 will then be pulled out of the hole and the 2 cut off above the packer and a 100 plug set above the packer to isolate he top of the formation. The plugging process was done in such a way as to isolate the packer and producing formation and abandon the packer in the well bore.
0518460205 2010-03-16 Production Wells Violations Noted Well has no id. Well is supplied with a 2tubing and a valve.
0542156170 2016-09-22 Final Restoration No Violations Final Restoration status check inspection accompanying Inspector Bill Stolarik found the well has been plugged and the site restored according to ORC 1509.072.
1086686619 2016-01-06 Plug / Plug Back No Violations On this day I accompanied ODNR Inspectors Bill Stolarik and Eric Conrad for the plugging of this well as follows: With the bottom hole plug set in place the previous day, Timco Wireline shot 5 shots in the 2 inch tubing at 1426 feet, followed by 1 shot at 942 feet and one shot at 932 feet, also into the 2 inch tubing. Then, Formation Cementing placed three 500 foot cement plugs inside the 2 inch tubing, in lifts, until cement reached surface. Finally a 100 foot cement placement was pumped down 1inch tubing placed outside the 2 inch tubing, bringing cement to surface. The service rig onsite was operated by Harmon Well Service.
1136548004 2010-03-16 Production Wells Violations Noted John Ackerman called with a complaint on the idle well. I will call Ed Crum on the complaint. The well is shut in. The well needs on the CGO bond. The records show never filing production reports. Need to file form 10.
1166474172 2016-01-07 Plug / Plug Back No Violations On this day I was on site along with MRI 2 Jim Nicholson to witness the plugging process in part with Formation Cementing on location and pressure testing the 2 tubing string to 250 psi verify integrity. The service rig verified a top of cement at 1,482 along with Timcos wireline service. The tubing was then perforated with 5 shots at a collar closest to the cement top. Inspector Eric Conrad arrived as my relief at 11:30 am.
1352309270 2012-11-07 Production Wells No Violations Inspection per request of Steve Opritza and the landowner John Ackerman. Upon inspection a well with 2 tubing only was found and proper identification was present. The production valves were open and a pressure gauge read 6psi.
1464392574 2012-02-13 Production Wells Violations Noted I received a call from John Ackerman who is concerned about the production of this well. Production has not been submitted for two years. The production that is submitted shows a history of production under the minimum standard. Mr. Ackerman states he has requested a report of production and has not received one in two years. This well is owned by C G O INC. Well shall be plugged or application shall be submitted for temporary inactive status.
1487862935 2016-01-06 Plug / Plug Back No Violations I am accompanied by inspector Jim Nicholson today our inspection finds the bottom hole plug was set in place the previous day. Timco Wireline shot five shots in the two inch tubing at 1426 feet, followed by one shot at 942 feet and one shot at 932 feet, also into the two inch tubing. Then, Formation Cementing placed three 500 foot cement plugs inside the two inch tubing, in lifts, until cement reached surface. Finally, a 100 foot cement plug was pumped down one inch tubing placed outside the two inch tubing, bringing cement to surface. The service rig onsite was operated by Harmon Well Service.
1525810583 2016-09-22 Final Restoration No Violations Final Restoration status check inspection accompanied by ODNR Division staff member Jimmy Wiles with the following being observed at the former well site. The well site has been restored according ORC 1509.072 with erosion control in place and vegetation established.
518460205 2010-3-16 0:00: PW No Violations 1.00
78948384 2010-10-29 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0389981594 US-OH-124126 2016-06-03 Statement of annual production not filed
0518460205 US-OH-125655 2010-04-20 Failure to legibly identify well
1136548004 US-OH-103444 2010-04-20 Well shall be plugged
1136548004 US-OH-103445 2010-04-20 Failure to register/obtain or maintain bond/insurance
1136548004 US-OH-103446 2010-04-20 Statement of annual production not filed
1464392574 US-OH-113442 2016-06-06 Nonproduction; well shall be plugged or placed in temporary inactive status
1464392574 US-OH-113443 2016-06-06 Statement of annual production not filed
1464392574 US-OH-113444 2016-06-06 Failure to report production to royalty holders

For data sources see[7]