If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-111-24352 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.78,"lon":-81.07,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Monroe | |
Municipality: Center Township | |
Operator Name: BECK ENERGY CORPORATION | |
Well Pad ID: | |
Farm/Lease Name: PNIACZEK | |
License Status: Producing | |
License Date: 2012-08-01 | |
Spud Date: 2012-08-30 | |
Spud Drilling Contractor: MONROE DRILLING OPERATION, LLC | |
Final Drill Date: 2013-10-31 | |
Well Total Depth: 2610.00 ft | |
Configuration: Vertical | |
Latitude: 39.780000 | |
Longitude: -81.070000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-08-01 | Proposed Formations:BEREA/30 FOOT/GORDON, Issued Date:8/1/2012, Expired Date:8/1/2014 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2013-10-31 | |
Completion Report Received | 2014-07-07 | |
Construction Permit Expires | 2014-08-01 | |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-07-09 | 1672 | 2351 | 51 |
1672 | 2351 | 51 | |
1672 | 2351 | 51 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-11-11 | H2O | 0 | 166883 Gal | 0 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | BECK ENERGY CORPORATION | 439.00 | 119.00 | 352 |
2015 | BECK ENERGY CORPORATION | 185.00 | 104.00 | 365 |
2016 | BECK ENERGY CORPORATION | 111.00 | 0.00 | 365 |
2017 | BECK ENERGY CORPORATION | 29.00 | 0.00 | 365 |
2018 | BECK ENERGY CORPORATION | 78.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | BECK ENERGY CORPORATION | Brine | 927 | 352 |
2015 | BECK ENERGY CORPORATION | Brine | 150 | 365 |
2016 | BECK ENERGY CORPORATION | Brine | 0 | 365 |
2017 | BECK ENERGY CORPORATION | Brine | 0 | 365 |
2018 | BECK ENERGY CORPORATION | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1346698721 | 2012-08-30 | Drill / Deepen / Reopen | No Violations | Inspector called for 12pm to witness Conductor pipe being run and set, Monroe Drilling Rig on hole and encountered an underground aquifer at a depth of 23 and continuing on until approximately 58. Drilling rig using a air rotary method with large amounts of river gravel, sandstone and water being circulated out of the borehole. 64 of 9.625 conductor was run into hole and after several attempts the cement crew was able to break circulation but not establish circulation to surface. A attempt was made to cement conductor pipe. The job called for 18 sacks of cement and a total of 85 sacks was used with no returns to surface. With the remaining upper portion of the conductor being sealed by grouting from surface with a quick Crete mix per instruction of Southeast supervisor Rocky King. |
1347556301 | 2012-09-13 | Drill / Deepen / Reopen | No Violations | Status check on well location, 9.625 Conductor has been set, pit is open, Monroe drilling rig moved off of the hole due to injunction by landowner disputing lease. |
1363812620 | 2013-03-20 | Administrative Inspection | No Violations | Status report on well that was not completed after the conductor pipe was set due to a court ordered injunction, Ray Beck said the court action with the current landowner has been resolved but a second lawsuit filed that is currently unresolved has the well and least tied up in the civil matter to be resolved at a later date. |
1369246802 | 2013-05-22 | Administrative Inspection | No Violations | Status check inspection on the well drilling process that has not been completed. In my conversation with Ray Beck He indication that the lease is in legal litigation and He is waiting on the attorneys to come up with a legal resolution. The well has been spudded and the conductor has been set. |
1382372036 | 2013-10-21 | Drill / Deepen / Reopen | No Violations | Notification was received on this day from Kerry Brown with Monroe Drilling that they would be moving on the said well later this week to complete the drilling process after being on hold since last year after setting the conductor casing because of legal lease issues. |
1383056615 | 2013-10-28 | Casing String Witnessed | No Violations | On site inspection to witness to running and cementing of 550 of 7 surface casing, Universal well services cemented the casing with 115 sacks of Type 1 cement with 6 barrels of cement returns to surface and the casing pressure tested to 500 psi over lift pressure. |
1406819069 | 2014-07-31 | Preliminary Restoration | No Violations | Preliminary Restoration status check inspection found the well site restoration meets ORC 1509.072 with proper vegetation established on location and the following equipment present at the well head 4.5 production casing- 1.5 tubing and pumping rods with the production valves open and the well set up to be produced by the means of a pumping unit, at the production fluid storage area 2-100 barrel production tanks are presen along with a mechanical separator and gas sales meter with a current sales chart all located in an established dike area with proper well identification posted. |
For data sources see[9]