X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-24071

Well Details

Well ID: 34-111-24071
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Center Township
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: MONROE COUNTY COMMISSIONERS
License Status: Producing
License Date: 2006-12-21
Spud Date: 2007-04-16
Spud Drilling Contractor: MONROE DRILLING OPERATION, LLC
Final Drill Date: 2007-04-19
Well Total Depth: 2715.00 ft
Configuration: Vertical
Latitude: 39.770000
Longitude: -81.100000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-12-21 Proposed Formations:BEREA/30 FOOT/GORDON, Issued Date:12/21/2006, Expired Date:12/21/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-04-19
Reached Total Depth 2007-04-19
Completion Report Received 2007-10-30
Construction Permit Expires 2007-12-21
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-02-13 2362 2390 65
2008-02-13 2104 2111 28
2104 2111 28
2362 2390 65
2522 2538 49
2628 2640 7
2104 2111 28
2008-02-13 2628 2640 7
2008-02-13 2522 2538 49

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 THIS IS THE 2ND STAGE OF A 3-STAGE FRAC … NO SAND USED IN FRAC; ONLY A SINGLE FRAC WATER VOLUME WAS REPORTED… GM
H2O 0 0 0 THIS IS THE 3RD STAGE OF A 3-STAGE FRAC… NO SAND USED IN FRAC; ONLY A SINGLE FRAC WATER VOLUME WAS REPORTED FOR THE 3-STAGE FRAC… NO PRESSURES WERE REPORTED… GM
H2O 0 184000 Gal 0 THIS IS THE 1ST STAGE OF A 3-STAGE FRAC & ALSO INVOLVES THE FIFTH SAND… NO SAND USED IN FRAC; ONLY A SINGLE FRAC WATER VOLUME WAS REPORTED FOR THE 3-STAGE FRAC… NO PRESSURES WERE REPORTED… GM

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 BECK ENERGY CORPORATION 4205.00 605.00 0
2008 BECK ENERGY CORPORATION 2373.00 527.00 365
2009 BECK ENERGY CORPORATION 1923.00 655.00 365
2010 BECK ENERGY CORPORATION 1976.00 453.00 365
2011 BECK ENERGY CORPORATION 1405.00 389.00 365
2012 BECK ENERGY CORPORATION 1194.00 389.00 366
2013 BECK ENERGY CORPORATION 857.00 317.00 365
2014 BECK ENERGY CORPORATION 755.00 394.00 365
2015 BECK ENERGY CORPORATION 744.00 236.00 365
2016 BECK ENERGY CORPORATION 628.00 246.00 365
2017 BECK ENERGY CORPORATION 601.00 254.00 365
2018 BECK ENERGY CORPORATION 584.00 292.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 BECK ENERGY CORPORATION Brine 0
2008 BECK ENERGY CORPORATION Brine 42 365
2009 BECK ENERGY CORPORATION Brine 100 365
2010 BECK ENERGY CORPORATION Brine 71 365
2011 BECK ENERGY CORPORATION Brine 47 365
2012 BECK ENERGY CORPORATION Brine 38 366
2013 BECK ENERGY CORPORATION Brine 27 365
2014 BECK ENERGY CORPORATION Brine 44 365
2015 BECK ENERGY CORPORATION Brine 23 365
2016 BECK ENERGY CORPORATION Brine 18 365
2017 BECK ENERGY CORPORATION Brine 12 365
2018 BECK ENERGY CORPORATION Brine 12 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1536987849 2020-6-24 0:00: PW No Violations 0.80
-1735042153 2007-10-29 0:00 PL No Violations
-963689211 2008-10-23 0:00 PW No Violations
0963689211 2008-10-23 Production Wells No Violations WELL IS SUPPLIED WITH PUMP JACK AND 100BBL TANK.WELL HAS 2LINE COMING OFF OF HILL THE LINE NEEDS REMOVED.TALKED TO PUMPER BOGUSS.WELL HEAD NEEDS BULL PLUG.
1356618345 2012-12-27 Production Wells No Violations Inspection of the well head found the following equipment present- 4.5 production casing-1.5 tubing and pumping rods with the production valves open and the well being produced by the means of a pumping unit. At the production fluid storage area the following equipment was found in an established dike area with proper well identification present- A single 100 barrel production tank along with a separator and production gas sales meter with a active gas sales chart.
1371578648 2013-06-18 Production Wells No Violations On this day I received notification from Becky Sims at 12:26 PM that at 7:30 Am they found that the electrical timer had malfunctioned and not shut the well off allowing the 100 barrel production tank to overflow approximately 2 barrels in which was contained inside the dike area, Becky stated that crews were cleaning up the oil by means of a vacuum truck and would remain on site until they are complete. I responded and was on site at 1:50 Pm and witnessed select energys vacuum truck pulling the small amounts of oil out of hand dug holes in the surface of the dike area, no oil was present above the surface, only saturated amounts inside the gravel in the dike.
1375739165 2013-08-05 Production Wells No Violations Status check on tank battery that had the tank overflow showed the spill had been cleaned up and no signs of contamination present.
1735042153 2007-10-29 Preliminary Restoration No Violations Restoration work at site satisfactory,pit has been filled in and site restored and vegetation is starting to grow will need to be looked at again in the spring too ensure proper growth.

For data sources see[9]

References