Well Details

Well ID: 34-111-22620
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Malaga Township
Operator Name: C G O INC
Well Pad ID:
Farm/Lease Name: BLOCK ARTHUR
License Status: Producing
License Date: 1981-10-21
Spud Date: 1981-10-20
Spud Drilling Contractor:
Final Drill Date: 1981-10-25
Well Total Depth: 2592.00 ft
Configuration: Vertical
Latitude: 39.820000
Longitude: -81.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1981-10-20
CO 1981-10-21 30 BANDS CO INC GeoDate 10/21/81
Completed 1981-10-25
Reached Total Depth 1981-10-25
CO 1993-11-22 2849 C G O INC GeoDate 10/21/81
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2326 2496 2
2326 2496 2
2326 2496 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 BANDS COMPANY INC 1111.00 0.00 365
1993 C G O INC 146.00 0.00 250
1994 C G O INC 139.00 0.00 365
1995 C G O INC 105.00 0.00 365
1996 C G O INC 196.00 0.00 365
1997 C G O INC 232.00 0.00 365
1998 C G O INC 176.00 0.00 365
1999 C G O INC 128.00 0.00 365
2000 C G O INC 147.00 0.00 365
2001 C G O INC 161.00 0.00 365
2002 C G O INC 187.00 0.00 365
2003 C G O INC 172.00 0.00 365
2004 C G O INC 87.00 0.00 180
2005 C G O INC 132.00 0.00 365
2006 C G O INC 123.00 0.00 300
2007 C G O INC 113.00 0.00 180
2008 C G O INC 0.00 0.00 0
2009 C G O INC 107.00 0.00 121
2010 C G O INC 321.00 0.00 365
2011 C G O INC 243.00 0.00 365
2012 C G O INC 272.00 1.00 365
2013 C G O INC 114.00 0.00 180
2014 C G O INC 118.00 0.00 300
2015 C G O INC 157.00 0.00 365
2016 C G O INC 132.00 18.00 350
2017 C G O INC 139.00 11.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 BANDS COMPANY INC Brine 0 365
1993 C G O INC Brine 0 250
1994 C G O INC Brine 0 365
1995 C G O INC Brine 0 365
1996 C G O INC Brine 0 365
1997 C G O INC Brine 0 365
1998 C G O INC Brine 0 365
1999 C G O INC Brine 0 365
2000 C G O INC Brine 0 365
2001 C G O INC Brine 0 365
2002 C G O INC Brine 0 365
2003 C G O INC Brine 0 365
2004 C G O INC Brine 0 180
2005 C G O INC Brine 0 365
2006 C G O INC Brine 0 300
2007 C G O INC Brine 0 180
2008 C G O INC Brine 0 0
2009 C G O INC Brine 0 121
2010 C G O INC Brine 0 365
2011 C G O INC Brine 0 365
2012 C G O INC Brine 3 365
2013 C G O INC Brine 0 180
2014 C G O INC Brine 0 300
2015 C G O INC Brine 0 365
2016 C G O INC Brine 10 350
2017 C G O INC Brine 2 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1129019409 2012-3-21 0:00: PW No Violations 1.00
-54654690 2017-4-11 0:00: PW No Violations 1.50
0054654690 2017-04-11 Production Wells No Violations Compliance notice # 234208599 follow up inspection found the following present at the well head. The well is equipped with 4.5 diameter production casing and 1.5 diameter production tubing with tubing and casing well heads present. There is 2 valves attached to the casing well head with no flow lines present. Attached to the 1.5 tubing is a production cross tee with a rabbit catcher standing atop the cross and a 2 production flow line attached to the side port out of the cross tee selling into a 1.5 diameter plastic flow line with the production valve in the open position. Missing from the 1.5 production tubing well head is the time delay mechanical device to allow the plunger lift system to operate. There is no production tank or gas sales meter on site associated with the said well. No well identification is posted.
0234208599 2012-03-21 Production Wells Violations Noted On the day of my inspection well was capable of production. Well was complete with a plunger lift system. There was a 100 barrel oil storage tank beside the well. The well owner has not submitted production on this well since 1993. I contacted the owner and advised him of the violations noted.
1072965056 2018-11-06 Production Wells No Violations On this day, I am conducting a compliance notice follow-up inspection. There appears to be no change in status since the previous inspection. The well is equipped with an 8.625 inch diameter surface casing head, 4.5 inch diameter production casing, and 1.9 inch diameter tubing. It is setup to be produced by means of a plunger lift system. There are no flowlines present on the 4.5 inch casing head, but a pressure gauge is attached, reading 160 psi. There is a production cross tee attached to the 1.9 inch tubing, with a flowline connected on one side with the production valve open. No plunger lift timer is attached to the wellhead. The production facility consists of (1) 100 barrel steel tank, (2) drip tanks, a vertical separator, and a domestic meter all contained within an earthen dike. It will be noted that the facility is shared with permit number 2-1984. The production records are current and the tank is properly identified. Updated pictures were taken. I spoke with landowner, Charles Edwards, during the inspection and he indicated that he doesnt receive domestic gas from the well. No identification is present at the wellhead. Updated pictures were taken.
1129019409 2012-03-21 Production Wells No Violations FOLLOW UP TO NOV # 234208599 On the day of my inspection well was capable of production. Well was complete with a plunger lift system. There was a 100 barrel oil storage tank beside the well. The well owner has not submitted production on this well since 1993. I contacted the owner and advised him of the violations noted. 10/03/13 production records have been reported on the well, Inspector Bill Stolarik.
234208599 2012-3-21 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0234208599 US-OH-122330 2012-03-26 Nonproduction; well shall be plugged or placed in temporary inactive status
0234208599 US-OH-122331 2012-03-26 Statement of annual production not filed

For data sources see[9]