X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-22554

Well Details

Well ID: 34-111-22554
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Malaga Township
Operator Name: C G O INC
Well Pad ID:
Farm/Lease Name: REISHMAN VERNON
License Status: Producing
License Date: 1981-08-31
Spud Date: 1981-10-01
Spud Drilling Contractor:
Final Drill Date: 1981-10-06
Well Total Depth: 2470.00 ft
Configuration: Vertical
Latitude: 39.810000
Longitude: -81.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-08-31 30 BANDS CO INC GeoDate 8/31/81
Original Spud 1981-10-01
Completed 1981-10-06
Reached Total Depth 1981-10-06
CO 1993-09-28 2849 C G O INC GeoDate 8/31/81
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2042 2049 6
2042 2049 6
2042 2049 6

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BANDS COMPANY INC 850.00 119.00 0
1985 BANDS COMPANY INC 10785.00 257.00 365
1986 BANDS COMPANY INC 3490.00 117.00 365
1987 BANDS COMPANY INC 2348.00 77.00 365
1988 BANDS COMPANY INC 2279.00 78.00 365
1989 BANDS COMPANY INC 1639.00 35.00 365
1990 BANDS COMPANY INC 993.00 21.00 365
1991 BANDS COMPANY INC 883.00 0.00 365
1992 BANDS COMPANY INC 671.00 0.00 365
1993 BANDS COMPANY INC 496.00 0.00 365
1994 C G O INC 381.00 0.00 365
1995 C G O INC 490.00 0.00 365
1996 C G O INC 382.00 0.00 365
1997 C G O INC 372.00 0.00 365
1998 C G O INC 401.00 0.00 365
1999 C G O INC 387.00 0.00 365
2000 C G O INC 487.00 0.00 365
2001 C G O INC 492.00 0.00 365
2002 C G O INC 521.00 0.00 365
2003 C G O INC 402.00 0.00 365
2004 C G O INC 307.00 0.00 365
2005 C G O INC 170.00 0.00 365
2006 C G O INC 241.00 0.00 365
2007 C G O INC 312.00 0.00 365
2008 C G O INC 287.00 0.00 365
2009 C G O INC 303.00 0.00 365
2010 C G O INC 432.00 0.00 365
2011 C G O INC 328.00 0.00 365
2012 C G O INC 372.00 0.00 365
2013 C G O INC 311.00 0.00 340
2014 C G O INC 232.00 0.00 365
2015 C G O INC 278.00 0.00 365
2016 C G O INC 223.00 2.00 350
2017 C G O INC 124.00 5.00 360

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BANDS COMPANY INC Brine 0 0
1985 BANDS COMPANY INC Brine 0 365
1986 BANDS COMPANY INC Brine 0 365
1987 BANDS COMPANY INC Brine 0 365
1988 BANDS COMPANY INC Brine 0 365
1989 BANDS COMPANY INC Brine 0 365
1990 BANDS COMPANY INC Brine 0 365
1991 BANDS COMPANY INC Brine 0 365
1992 BANDS COMPANY INC Brine 0 365
1993 BANDS COMPANY INC Brine 0 365
1994 C G O INC Brine 0 365
1995 C G O INC Brine 0 365
1996 C G O INC Brine 0 365
1997 C G O INC Brine 0 365
1998 C G O INC Brine 0 365
1999 C G O INC Brine 0 365
2000 C G O INC Brine 0 365
2001 C G O INC Brine 0 365
2002 C G O INC Brine 0 365
2003 C G O INC Brine 0 365
2004 C G O INC Brine 0 365
2005 C G O INC Brine 0 365
2006 C G O INC Brine 0 365
2007 C G O INC Brine 0 365
2008 C G O INC Brine 0 365
2009 C G O INC Brine 0 365
2010 C G O INC Brine 0 365
2011 C G O INC Brine 0 365
2012 C G O INC Brine 0 365
2013 C G O INC Brine 0 340
2014 C G O INC Brine 0 365
2015 C G O INC Brine 0 365
2016 C G O INC Brine 1 350
2017 C G O INC Brine 2 360

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2125322439 2012-3-21 0:00: PW No Violations 2.00
-918198138 2013-4-10 0:00: PW No Violations
0918198138 2013-04-10 Production Wells No Violations Inspection found the prior compliance agreement 2125322439 for no well identification resolved at this time. Inspection of the well head found the following equipment present 2.875 intermediate casing string- 1.5 production tubing with the production valves open and the well being produced by the means of a plunger lift system. A single 100 barrel production tank is present in an established dike along with a mechanical separator and gas sales meter with a current sales chart. Proper well identification is posted.
1432718261 2012-03-21 Production Wells No Violations FOLLOW UP TO NOV # -2125322439 On the day of my inspection the well was complete with a plunger lift system. All wells on this lease (1986, 2553, 2554) feed into same tank battery which contains one 100 barrel oil storage tank and a mechanical separator. This does not have an ID at the well head to distinguish from other wells. Owner has not submitted production reports.
2125322439 2012-03-21 Production Wells Violations Noted On the day of my inspection the well was complete with a plunger lift system. All wells on this lease (1986, 2553, 2554) feed into same tank battery which contains one 100 barrel oil storage tank and a mechanical separator. This does not have an ID at the well head to distinguish from other wells. Owner has not submitted production reports.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2125322439 US-OH-121768 2012-03-26 Failure to legibly identify well
2125322439 US-OH-121769 2012-03-26 Nonproduction; well shall be plugged or placed in temporary inactive status
2125322439 US-OH-121770 2012-03-26 Statement of annual production not filed

For data sources see[9]

References