34-105-23689

Well Details

Well ID: 34-105-23689
Loading map...
Country: United States
State: Ohio
County: Meigs
Municipality: Orange Township
Operator Name: DURST OIL & GAS INC
Well Pad ID:
Farm/Lease Name: DURST RONALD W JR
License Status: Producing
License Date: 2011-11-02
Spud Date: 2011-12-12
Spud Drilling Contractor: MONROE DRILLING OPERATION, LLC
Final Drill Date: 2011-12-15
Well Total Depth: 1800.00 ft
Configuration: Vertical
Latitude: 39.140000
Longitude: -81.930000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-11-02 Proposed Formations:BEREA, Issued Date:11/2/2011, Expired Date:11/1/2013 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-12-15 BASED ON CHIEF'S ORDER 2017-289 AD AUTHORIZATION IS REVOKED. WELL TYPE WAS CHANGED TO TAAD ON 8/21/2017|
Completion Report Received 2013-03-15 BASED ON CHIEF'S ORDER 2017-289 AD AUTHORIZATION IS REVOKED. WELL TYPE WAS CHANGED TO TAAD ON 8/21/2017|
Construction Permit Expires 2013-11-01 BASED ON CHIEF'S ORDER 2017-289 AD AUTHORIZATION IS REVOKED. WELL TYPE WAS CHANGED TO TAAD ON 8/21/2017|
Revocation 2017-08-16 BASED ON CHIEF'S ORDER 2017-289 AD AUTHORIZATION IS REVOKED. WELL TYPE WAS CHANGED TO TAAD ON 8/21/2017|
Last Compliance Report 2017-08-21 BASED ON CHIEF'S ORDER 2017-289 AD AUTHORIZATION IS REVOKED. WELL TYPE WAS CHANGED TO TAAD ON 8/21/2017|
Record Last Modified 2017-10-24 BASED ON CHIEF'S ORDER 2017-289 AD AUTHORIZATION IS REVOKED. WELL TYPE WAS CHANGED TO TAAD ON 8/21/2017|

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2013-03-18 1586 1590 17
1586 1590 17
1586 1590 17

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-01-12 H2O 15 34836 Gal 23500 Universal Well Services Inc.
0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 DURST OIL & GAS INC 1305.00 30.00 240
2013 DURST OIL & GAS INC 619.00 47.00 365
2014 DURST OIL & GAS INC 953.00 0.00 360
2015 DURST OIL & GAS INC 1013.00 0.00 360
2016 DURST OIL & GAS INC 941.00 0.00 360
2017 DURST OIL & GAS INC 410.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 DURST OIL & GAS INC Brine 120 240
2013 DURST OIL & GAS INC Brine 150 365
2014 DURST OIL & GAS INC Brine 75 360
2015 DURST OIL & GAS INC Brine 80 360
2016 DURST OIL & GAS INC Brine 150 360
2017 DURST OIL & GAS INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1092223988 2011-12-14 0:00 AD No Violations
-157529946 2012-10-11 0:00 DD No Violations 0.30
-1634903817 2012-4-27 0:00: PL No Violations 0.80
-1827042758 2020-7-29 0:00: AD No Violations 1.50
-1891285481 2011-12-13 0:00 AD No Violations
-278718191 2012-2-27 0:00: AD No Violations
-307276367 2017-7-5 0:00:0 PW No Violations 0.50
-352565403 2012-11-13 0:00 PL No Violations 1.00
0014534757 2011-11-29 Drill / Deepen / Reopen No Violations Site moved to be farther from creek and toward higher ground. New stake is roughly 50 feet from GPS position in RBDMS.
0060929195 2017-07-20 Production Wells No Violations Well has been properly identified.
0157529946 2012-10-11 Drill / Deepen / Reopen No Violations Grass seed had not been laid down yet. I spoke with Ron Durst in the field and he assured me grass would be laid down next week.
0278718191 2012-02-27 Annular Disposal No Violations Annular disposal test. 329 psi nitrogen test for one hour. Dropped 1 psi in an hour. Blew down the annulus after the test.
0307276367 2017-07-05 Production Wells Violations Noted This well was not properly identified. I texted Mr. Durst about this and other wells and asked if he could identify them. He texted back and stated he was consulting out of state for Columbia gas and said the wells would be identified in 2.5 weeks when he was done.
0352565403 2012-11-13 Preliminary Restoration No Violations Follow up to inspection 1231388534. The pits have been filled, there is no drilling equipment on site, the area has been graded, and vegetative cover is returning.
0865097542 2012-01-12 Drill / Deepen / Reopen No Violations Witnessed well stimulation. Hydro Frac.
1092223988 2011-12-14 Annular Disposal No Violations Accompanied by Josh Garland MRI. Fresh water annular disposal test. Hydrostatic test of the surface casing using fresh water. 645 feet of surface casing cemented with 243 sacks. Test pressure 329 psi. Allowed air to work out of surface casing water over night. Tested 3 additional times (not counting 4 tests on 12-13-11) and failed all tests. Water level in casing stayed at surface. Test equipment was checked for leaks, none found.
1231388534 2012-09-12 Preliminary Restoration Violations Noted Pits filled, drilling equipment removed, area has been graded off. Vegetative cover has not been established. I spoke with Ron Durst about his restoration plans for the well as well as others in the area.
1323784241 2011-12-13 Drill / Deepen / Reopen No Violations 645 feet of 8 5/8 inch surface casing set in 690 feet of 11 inch borehole. Circulation established with good cement returns staying at surface with 243 sacks of Class A neat cement. 300 lbs gel, 700 lbs accelerator, and 200 lbs cottonseed hulls.
1323836814 2011-12-13 Annular Disposal No Violations 645 feet of 8 5/8 surface casing. 330 psi minimum for freshwater mechanical integrity test. Attempted test four times and failed each time. Will return tomorrow to try alternative.
1324001994 2011-12-15 Drill / Deepen / Reopen No Violations Witnessed longstring cement job. 1736 feet of 5 1/2 casing cemented into 7 7/8 borehole. Total depth 1799 feet. 70 sacks class A regular cement, 50lb gel, 25 lb LCM.
1330447598 2012-02-27 Annular Disposal No Violations Witnessed Annular Disposal test with Jon Scott. 331 psi was held on the annulus with Nitrogen for one hour. The test passed on the third attempt. Witnessed the blow down afterwards.
1330455247 2012-02-28 Annular Disposal No Violations Tested line from tanks to wellhead for integrity. Held 35 psi for 15 minutes with no drop in pressure.
1353199231 2011-12-14 Annular Disposal No Violations Attempted freshwater mechanical integrity test again with an alternative pump. Unable to hold minimum pressure for required time with out a loss of 5% or more.
14534757 2011-11-29 0:00 DD No Violations 0.50
1615392508 2012-10-18 Drill / Deepen / Reopen No Violations Grass seed had been laid down and the area has been mulched. The drilling pits are closed and the area has been graded, there is no drilling equipment on site. Waiting on vegetative cover to be established to pass restoration.
1634903817 2012-04-27 Preliminary Restoration No Violations Pit has been closed for 2 month restoration requirements.
1788614981 2011-12-05 Drill / Deepen / Reopen No Violations Building location today. Reviewed pit location with Jason Meadows of Meadows construction.
1891285481 2011-12-13 Annular Disposal No Violations Accompanied by Josh Garland MRI. Fresh water annular disposal test. Hydrostatic test of the surface casing using fresh water. 645 feet of surface casing cemented with 243 sacks. Test pressure 329 psi. Tested 4 times and failed all tests. Water level in casing stayed at surface. Test equipment was checked for leaks, none found.
2102851760 2012-07-05 Preliminary Restoration No Violations Preliminary restoration check. Pits have been filled and the area has been graded. The area has not been seeded and mulched. Dry conditions made establishing vegetative cover unlikely. Extension granted due to weather.
60929195 2017-7-20 0:00: PW No Violations 0.50
707661045 2020-9-3 0:00:0 AD No Violations 3.00
865097542 2012-1-12 0:00: DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0307276367 US-OH-123196 2017-09-19 9-9-05(A)10 Failure to legibly identify well
1231388534 US-OH-106225 2012-11-14 Failure to restore within six months

For data sources see[9]

References