If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-105-23652 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":38.93,"lon":-81.78,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Meigs | |
Municipality: Lebanon Township | |
Operator Name: ROSCOE MILLS JR TRUST | |
Well Pad ID: | |
Farm/Lease Name: MILLS ROSCOE (SWIW #21) | |
License Status: Active Injection | |
License Date: 2013-12-20 | |
Spud Date: 2009-09-30 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2009-10-07 | |
Well Total Depth: 5835.00 ft | |
Configuration: Vertical | |
Latitude: 38.930000 | |
Longitude: -81.780000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-02-20 | Proposed Formations:NEWBURG, CLINTON, MEDINA, Issued Date:2/20/2009, Expired Date:2/20/2010 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:OG, Proposed Well Class:EDPW |
Reached Total Depth | 2009-10-07 | |
Completion Report Received | 2009-12-16 | |
Change of Owner | 2013-08-21 | Operator changed from 490, HILL DAVID R INC to 8272, MILLS ROSCOE |
Annulus Pressure Monitoring Approved | 2013-10-09 | |
APP | 2013-12-20 | Proposed Formations:CLINTON, Issued Date:12/20/2013, Expired Date:12/20/2015 12:00:00 PM, Drilling unit acres:50, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Last Compliance Report | 2014-02-14 | |
Construction Permit Expires | 2015-12-20 | |
Change of Owner | 2016-08-03 | Operator changed from 8272, MILLS ROSCOE to 9731, ROSCOE MILLS JR TRUST |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-02-19 | 5593 | 5656 | 76 |
5593 | 5656 | 76 | |
5593 | 5656 | 76 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 79000 Gal | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | DAVID R HILL INC | 733.00 | 0.00 | 15 |
2010 | DAVID R HILL INC | 6825.00 | 0.00 | 365 |
2011 | DAVID R HILL INC | 4897.00 | 0.00 | 365 |
2012 | DAVID R HILL INC | 4897.00 | 0.00 | 366 |
2013 | DAVID R HILL INC | 3342.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | DAVID R HILL INC | Brine | 0 | 15 |
2010 | DAVID R HILL INC | Brine | 151 | 365 |
2011 | DAVID R HILL INC | Brine | 92 | 365 |
2012 | DAVID R HILL INC | Brine | 0 | 366 |
2013 | DAVID R HILL INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1060835555 | 2009-11-6 0:00: | DD | No Violations | |
-1079477400 | 2019-5-22 0:00: | SW | No Violations | 1.00 |
-1081935178 | 2020-6-15 0:00: | SW | No Violations | 1.00 |
-113345529 | 2018-8-22 0:00: | SW | No Violations | 0.50 |
-1194780916 | 2018-11-5 0:00: | SW | No Violations | 2.00 |
-1219320065 | 2018-12-11 0:00 | SW | No Violations | 1.00 |
-1294796579 | 2014-1-2 0:00:0 | SC | No Violations | 2.00 |
-1422353299 | 2014-2-20 0:00: | SW | No Violations | 2.00 |
-1434134457 | 2019-7-18 0:00: | SW | No Violations | 1.00 |
-146070768 | 2014-2-27 0:00: | SW | No Violations | 8.00 |
-1528571756 | 2014-10-20 0:00 | SW | No Violations | 1.00 |
-1626691300 | 2019-4-9 0:00:0 | SW | No Violations | 0.50 |
-1637404941 | 2015-2-26 0:00: | SW | No Violations | 3.20 |
-1792643094 | 2015-2-23 0:00: | SW | No Violations | 1.00 |
-1798700790 | 2014-8-26 0:00: | SW | No Violations | 1.50 |
-1889847227 | 2019-4-17 0:00: | SW | No Violations | 2.50 |
-2086414910 | 2013-10-15 0:00 | PW | No Violations | 3.00 |
-26957590 | 2014-6-17 0:00: | SW | No Violations | 1.50 |
-324702917 | 2014-12-4 0:00: | SW | No Violations | 1.50 |
-401003955 | 2015-5-13 0:00: | SW | No Violations | 1.50 |
-468917344 | 2020-2-19 0:00: | SW | No Violations | 1.00 |
-501480068 | 2019-2-7 0:00:0 | SW | No Violations | 0.70 |
-553401678 | 2019-6-10 0:00: | SW | No Violations | 1.00 |
-568667521 | 2019-12-9 0:00: | SW | No Violations | 0.50 |
-583138494 | 2015-5-14 0:00: | SW | No Violations | 4.50 |
-687907736 | 2017-8-29 0:00: | SW | No Violations | 2.40 |
-75808506 | 2018-3-26 0:00: | SW | No Violations | 2.00 |
-774757336 | 2015-11-24 0:00 | SW | No Violations | 1.00 |
-79709946 | 2019-1-7 0:00:0 | SW | No Violations | 0.70 |
-860667344 | 2015-5-12 0:00: | SW | No Violations | 1.50 |
-878693094 | 2014-9-2 0:00:0 | SW | No Violations | 3.00 |
-903796160 | 2017-6-28 0:00: | SW | No Violations | 1.40 |
-982301935 | 2019-12-24 0:00 | SW | No Violations | 0.50 |
0026957590 | 2014-06-17 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Good identification at the wellhead. |
0044916739 | 2015-09-01 | Salt Water Injection Well | No Violations | Inspected the Mills API# 3410523619 facility, injection pump, injection pressure and annulus pressure. |
0054234083 | 2014-10-15 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification posted at well. |
0064059656 | 2017-11-16 | Salt Water Injection Well | No Violations | My inspection revealed the salt water injection well had 360 psi on the annulus and 1140 psi on the injection tubing. The well has a legible identification. |
0075808506 | 2018-03-26 | Salt Water Injection Well | No Violations | The salt water injection well had 360 psi on the injection tubing and 55 psi on the annulus. The dike was free of fluids. Legible identification was posted. |
0079709946 | 2019-01-07 | Salt Water Injection Well | No Violations | Inspected the Mills surface facility, injection pressure and annulus pressure. Identification is posted. |
0112760287 | 2013-10-07 | Production Wells | No Violations | Authorization to run an injectivity test was granted on 9-12-2013 expires on 10-13-13. Witnessed new Baker Hughes A3 LOK Set Packer with ON /OFF Tool ran with new 2 3/8 4.7 lb tubing. Packer ran to 5532.65 (center of element). Packer was not set. Waiting on pump truck to set packer. Scheduled for 10-9-13. |
0113345529 | 2018-08-22 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification is posted. |
0139860596 | 2013-10-10 | Production Wells | No Violations | Authorization to run an injectivity test was granted on 9-12-2013 expires on 10-13-13. 1200 psi injection pressure. Mud pump had multiple leaks and had to be shut down to repair the leaks. Injection resumed after repairs were made and 4 hose was replaced. |
0146070768 | 2014-02-27 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 506440311 Inspection of the well site during the initial injection revealed a brine contaminated area extending 30 feet by 20 feet from the wellhead. The well casing had salt crystals and the wellhead ring contained brine. A field test of the contaminated soil with a High Range Quantab revealed a Chloride level over 6508 ppm Cl (highest level of the Quantab). Another High Range Quantab was placed in the brine on the wellhead it revealed a Chloride level over 6508 ppm Cl (highest level of the Quantab). I called the South West Region Supervisor and was told to collect 2 soil samples from the contaminated area and 1 control sample. I also collected a brine sample from the brine pooled on the wellhead. The samples were taken to the ODNR Lab. Wes Harmon and Rick Zickefoose (both from Green Hunter Water) were told on site to remove the contaminated soil. The contaminated soil must be hauled to an approved EPA landfill for disposal. |
0148689753 | 2017-01-17 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Inspected the Mills surface facility. |
0324141076 | 2017-03-10 | Salt Water Injection Well | No Violations | Inspected the Mills Facility 34-105-23619, injection pressure and annulus pressure. Identification posted. |
0324702917 | 2014-12-04 | Salt Water Injection Well | No Violations | Inspected the injection pressure, annulus pressure, and the surface facility of #34-105-23619 Mills # 2. |
0356074292 | 2016-03-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED |
0401003955 | 2015-05-13 | Salt Water Injection Well | No Violations | Inspected the Mills #1 facility, Injection pressure and annulus pressure. |
0501480068 | 2019-02-07 | Salt Water Injection Well | No Violations | Inspected the Mills surface facility, injection pressure and annulus pressure. Identification is posted. |
0506440311 | 2014-02-27 | Salt Water Injection Well | Violations Noted | Inspection of the well site during the initial injection revealed a brine contaminated area extending 30 feet by 20 feet from the wellhead. The well casing had salt crystals and the wellhead ring contained brine. A field test of the contaminated soil with a High Range Quantab revealed a Chloride level over 6508 ppm Cl (highest level of the Quantab). Another High Range Quantab was placed in the brine on the wellhead it revealed a Chloride level over 6508 ppm Cl (highest level of the Quantab). I called the South West Region Supervisor and was told to collect 2 soil samples from the contaminated area and 1 control sample. I also collected a brine sample from the brine pooled on the wellhead. The samples were taken to the ODNR Lab. Wes Harmon and Rick Zickefoose (both from Green Hunter Water) were told on site to remove the contaminated soil. The contaminated soil must be hauled to an approved EPA landfill for disposal. |
0583138494 | 2015-05-14 | Salt Water Injection Well | No Violations | Witnessed an acid stimulation by Producers Service Co. |
0616791392 | 2014-11-03 | Salt Water Injection Well | No Violations | Inspected the unloading pad, containment dike, tanks, and checked injection pressure and annulus pressure. |
0617771301 | 2017-02-21 | Salt Water Injection Well | No Violations | Inspected the Mills Surface Facility 34-105-23619, injection pressure and annulus pressure. Identification posted. |
0687907736 | 2017-08-29 | Salt Water Injection Well | No Violations | My inspection today revealed the injection well has 470 PSI on the annulus and 5 PSI on the injection tubing. Legible identification was posted. No violations noted. |
0774757336 | 2015-11-24 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification posted. Inspected the Mills Facility 3410523619. |
0860667344 | 2015-05-12 | Salt Water Injection Well | No Violations | Inspected the Mills #1 Surface Facility. The Murphy pressure cut off switch on the injection pump for the Mills #2 was set at 1370 psi. I told Wes Harmon to set it at the max injection pressure of 1290 psi. Inspected the injection pressure and annulus pressure. Identification was posted at the well site. |
0878693094 | 2014-09-02 | Salt Water Injection Well | No Violations | Acid treatment. Producers Service Corp. Pumped 2000 gallons of 28% HCL. Inspected the containment dike, tanks, injection pump, unloading pad, injection pressure and annulus pressure. |
0903796160 | 2017-06-28 | Salt Water Injection Well | No Violations | Salt water injection well inspection. The annulus pressure was 441 psi, the injection tubing pressure was 353 psi. No violations were noted during my inspection. |
0911679806 | 2016-10-18 | Salt Water Injection Well | No Violations | Compliance Notice # 1476727620 follow up inspection. The leak has been repaired. Wellhead has been cleaned up and painted. No leaks observed. |
1060835555 | 2009-11-06 | Drill / Deepen / Reopen | No Violations | Kilbarger service rig is on location. Drill pit has been closed. Mud pit is being used by service rig. No problems observed during inspection. |
1102044127 | 2018-02-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. REPORTS RECEIVED BY THE DIVISION ON FEBRUARY 26, 2018 |
112760287 | 2013-10-7 0:00: | PW | No Violations | 11.00 |
1173837769 | 2013-10-09 | Production Wells | No Violations | Authorization to run an injectivity test was granted on 9-12-2013 expires on 10-13-13. New Baker Hughes A3 LOK Set Packer with ON /OFF Tool ran with new 2 3/8 4.7 lb tubing. Packer ran to 5532.65 (center of element). Packer set with 5000 lbs compression. Tubing was released after setting the packer and fresh water with inhibitor was pumped through the tubing and circulated to a tank at the surface. Pumped 80.2 barrels fresh water with 10 gallons inhibitor. Sting tubing back onto packer and pressure up the tubing to 2257 psi to open the disk in packer. When disk was removed the tubing pressure went to vacuum. Tested annulus at 1360 psi for 15 minutes with a loss of 60 psi. Started injectivity test at 3:15 pm. |
1194780916 | 2018-11-05 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification is posted. |
1219320065 | 2018-12-11 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification is posted. |
1243408115 | 2018-09-28 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification is posted. |
1294796579 | 2014-01-02 | Surface Facility Construction | No Violations | Meet on location with Roscoe Mills, John Jack (Green Hunter) and Contractor to review injection line installation and proposed route including utilizing an existing 7 steel conduit that runs under Route 33. Installation of a centralizer or other form of barrier between the Fiber spar Injection line and the 7 steel conduit was discussed. |
1315224135 | 2016-07-07 | Salt Water Injection Well | No Violations | Inspected the Mills Surface facility, injection pump, injection pressure and annulus pressure. Identification posted. |
1317834954 | 2011-10-05 | Preliminary Restoration | No Violations | Pits have been filled and the area graded and seeded with good vegetative cover and no erosion. Preliminary Restoration passed. |
1332837059 | 2018-03-05 | Salt Water Injection Well | No Violations | The salt water injection well had 372 psi on the injection tubing and 174 psi on the annulus. The well has a legible identification. |
1340188238 | 2020-1-14 0:00: | SW | No Violations | 8.70 |
1378746221 | 2013-09-09 | Completion Testing | No Violations | Witnessed 500 gallons 15% HCl being spot to perforations. Pressure and rate recorded. |
1386771723 | 2013-12-09 | Production Wells | No Violations | Request for inspection from Andrew Adgate ODNR DOGRM Geologist UIC Section. Site evaluation for salt water injection well permit. Located and collected GPS coordinates on Water wells within close proximity to the proposed injection well. 1st water well at Roscoe Mills residence N38.93013 / W 081.78795, 957 feet from the proposed injection well. 2nd water well N38.93076 / W081.78745, 747 feet from the proposed injection well. 3rd water well N38.93464 / W081.79388, 1757 feet from the proposed injection well. 4th water well N38.93140 / W081.78984, 681 feet from the proposed injection well. 5th water well N38.935704 / W081.78835, 2056 feet from the proposed injection well. The Ohio River is 1365 feet South West of the proposed injection well. |
1393550350 | 2014-02-27 | Salt Water Injection Well | Violations Noted | Convert to Salt Water Injection Well Permit Issued on 12-20-13. Permit and Constructional Conditions Number 4. State that the Mineral Resources Inspector must be notified at a minimum of 48 hours in advance of the time of initial injection so that a representative of the Division can be present to witness the operations. I was notified by Wes Harmon (Green Hunter Water) on 2-26-14 at 2:09 pm that they received the Chiefs Order to inject. Wes wanted me to come to the site on 2-26-14. I told Wes that I was currently in Vinton County and could not come to the well on 2-26-14. I said that I could be there first thing in the morning on 2-27-14. At 3:49 pm. On 2-26-14 I received a voice message from John Jack (Green Hunter Water) That said that they are going to start injection tonight 2-26-14. I responded (as soon as I had a clear cell signal) that The permit conditions require 48 hours notice. I did again offer to be at the well on 2-27-14 in the morning. I received no other messages in regards to the issue until 8:11 am on 2-27-14 when Wes Harmon called and asked if I was coming to the well. I arrived at the surface facility at 9:40 am on 2-27-14. The pumps were off and I was told that they did inject 300 barrels on 2-26-14. |
1394035819 | 2014-03-05 | Salt Water Injection Well | No Violations | Compliance Notice Follow Up to Compliance Notice Issued on 2-27-14. Well site is snow covered. Wes Harmon (Green Hunter Water) told me that they removed approximately 8 tons of soil from the location. The soil was placed in a roll off dumpster and taken to landfill. Well site is graded. No leaks were observed on the injection line, or injection tubing. Injection psi during inspection was 1220 psi. I told Wes Harmon and Roscoe Mills that they need identification at the wellhead and the surface facility. Currently there is identification at the 100 barrel production tank beside the lease road. This tank and equipment are not part of the injection operations. |
1394554744 | 2014-03-11 | Salt Water Injection Well | No Violations | Witnessed injectivity test at well. Pressures and rates recorded. 1000 gallons of 15% HCl displaced to perforations with 12 Barrels (Bbl) filtered brine. Allowed to set for 30 minutes, and then another 1000 gallons 15% HCl displaced with another 68 bbl filtered brine. Total volume used 119 Bbl, at an average rate of 1.4 Bbl/minute. Average psi of treatment was 1270, with an Instantaneous Shut-in pressure of 1006 psi and a 5 minute shut-in of 943 psi. the pressure on the annulus was measured at 480 psi after the treatment. |
139860596 | 2013-10-10 0:00 | PW | No Violations | |
1404149332 | 2014-06-30 | Salt Water Injection Well | No Violations | Follow up to 2117246597. Fittings replaced. |
1412607460 | 2014-10-06 | Salt Water Injection Well | No Violations | Inspected the injection pressure, and annulus pressure. Identification posted on wellhead. |
1416143396 | 2016-03-02 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd, & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016.REPORTS RECEIVED 3/8/2016. |
1418756719 | 2014-12-16 | Salt Water Injection Well | No Violations | Inspected the injection pressure, annulus pressure and the surface facility at the Mills # 1 API #34-105-23619. |
1420829955 | 2015-01-09 | Salt Water Injection Well | No Violations | Inspected the injection well site, checked the injection pressure and annulus pressure. Inspected the Mills # 1 surface facility. Checked the containment dike, tanks, injection pumps, and unloading pads. |
1422353299 | 2014-02-20 | Salt Water Injection Well | No Violations | Inspected status of the well. Currently annulus is pressurized and injection line is connected to the Mills # 1 surface facility. Injection line valves are closed. |
1428926672 | 2015-04-09 | Surface Facility Construction | No Violations | On site meeting with Green Hunter and UIC Section staff. Discussed proposed additions to facility and pipelines to proposed injection wells. |
1434563617 | 2015-06-17 | Salt Water Injection Well | No Violations | Inspected the surface facility of the Mills # 1 and 2. Witnessed brine trucks unloading on the pad. Inspected the injection pressure and annulus pressure. Identification posted at the well and on the facility access road. |
1437464960 | 2016-05-23 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification posted. The entrance to the access road was blocked off with a metal tank ladder and a 6 steel pipe. |
1445604518 | 2015-10-21 | Salt Water Injection Well | No Violations | Inspected the Mills Facility API# 34-105-23619. Inspected the injection pressure and annulus pressure. Wes Harmon was on site and we discussed the corroded 2 tee with salt build up on the injection tubing. Wes said that they will replace the fittings. |
1460020401 | 2014-07-21 | Salt Water Injection Well | No Violations | Inspected the injection pressure, annulus pressure, containment dike, tanks, injection pump, and the unloading pad. Good identification at the well. Containment dike is free of fluids. |
1476727620 | 2016-10-17 | Salt Water Injection Well | Violations Noted | Inspected the Mills surface facility 3410523619. Inspected the injection pressure and annulus pressure. A small seep was observed on the injection line connecting to the injection tubing. A 4 inch nipple connecting two tees has evidence of a leak with salt build up on the lower fittings and wellhead. Wes Harmon was contacted about the seep. Wes sent a crew to repair the seep. |
148689753 | 2017-1-17 0:00: | SW | No Violations | 1.00 |
1524948225 | 2014-02-27 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 1393550350 Convert to Salt Water Injection Well Permit Issued on 12-20-13. Permit and Constructional Conditions Number 4. State that the Mineral Resources Inspector must be notified at a minimum of 48 hours in advance of the time of initial injection so that a representative of the Division can be present to witness the operations. I was notified by Wes Harmon (Green Hunter Water) on 2-26-14 at 2:09 pm that they received the Chiefs Order to inject. Wes wanted me to come to the site on 2-26-14. I told Wes that I was currently in Vinton County and could not come to the well on 2-26-14. I said that I could be there first thing in the morning on 2-27-14. At 3:49 pm. On 2-26-14 I received a voice message from John Jack (Green Hunter Water) That said that they are going to start injection tonight 2-26-14. I responded (as soon as I had a clear cell signal) that The permit conditions require 48 hours notice. I did again offer to be at the well on 2-27-14 in the morning. I received no other messages in regards to the issue until 8:11 am on 2-27-14 when Wes Harmon called and asked if I was coming to the well. I arrived at the surface facility at 9:40 am on 2-27-14. The pumps were off and I was told that they did inject 300 barrels on 2-26-14. |
1525700502 | 2018-05-03 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification posted. Accompanied by UIC Geologist. |
1528571756 | 2014-10-20 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification posted at well. |
1572620674 | 2020-4-6 0:00:0 | SW | No Violations | 1.00 |
1573155057 | 2019-10-30 0:00 | SW | No Violations | 1.00 |
1579611297 | 2020-1-8 0:00:0 | SW | No Violations | 6.50 |
1599240054 | 2016-12-14 | Salt Water Injection Well | No Violations | Inspected the Mills Surface Facility (34-105-23619), Injection pressure and annulus pressure. Identification posted. |
1626691300 | 2019-04-09 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification is posted. |
1637404941 | 2015-02-26 | Salt Water Injection Well | No Violations | Witnessed acid job on the Roscoe Mills #2. 1000 gallons of HCl were displaced through the tubing at 5532 feet and allowed to sit for 1/2 hour, then another 500 gallons of HCl were displaced to the perfs and allowed to sit for 1/2 an hour, then another 500 gallons were displaced. A total of 200 gallons used for the job. |
1717079268 | 2019-03-05 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. The annulus is frozen. Identification is posted. The 100 barrel production tank is still on the lease and appears to have fluid in it. A small wet area has formed on the tank at 30 inches off the ground with salt residue. I called Roscoe Mills Jr Trust phone number and left a message inquiring about the tank status. |
1792643094 | 2015-02-23 | Salt Water Injection Well | No Violations | Follow up on the repairs being made to the fire damaged unloading pad containment vault at the Roscoe Mills Surface facility 34-105-23619. The injection operations are shut down until the repairs are made to the vault. Excavation and removal of the damaged vault are on going. All fluids from the vault are being removed by a Roscoe Mills vacuum truck. Inspected the unloading pad, containment dike, tanks, injection pumps, injection pressure and annulus pressure. |
1798700790 | 2014-08-26 | Salt Water Injection Well | No Violations | Inspected the injection pressure, annulus pressure, injection line, injection pump, containment dike, and unloading pad. Identification posted at the well. A brine drip was observed on the 2 hammer union on the injection line. Another brine drip was observed at the 2 tee on top of the injection tubing. I talked to Wes Harmon (Green Hunter Water) about the brine drips. Wes is going to replace the fittings. |
184168542 | 2019-5-9 0:00:0 | SW | No Violations | 0.80 |
1889847227 | 2019-04-17 | Salt Water Injection Well | No Violations | Inspected the Injection pressure and Annulus pressure. Identification is posted. A new 1/4 inch needle valve has been installed on the injection tubing. |
2015554045 | 2018-04-30 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification is posted. |
2037340176 | 2019-04-04 | Salt Water Injection Well | No Violations | Inspected the injection pressure and annulus pressure. Identification posted. The 100 barrel production tank located at GPS N38.93159/W081.78831 has been emptied by Harmon Well Services Brine truck. |
2080856300 | 2015-06-02 | Salt Water Injection Well | No Violations | Inspected the Mills surface facility 3619, injection pressure and annulus pressure. |
2086414910 | 2013-10-15 | Production Wells | No Violations | All equipment for the injectivity test has been removed from the location. Site has been graded. Well is located in a corn field and no grass seed or mulch has been applied to the affected area. Tubing pressure was 520 and annulus pressure was 325. |
2117246597 | 2014-06-24 | Salt Water Injection Well | Violations Noted | Fittings too corroded to test injection or annulus. Well shall be equipped with functioning fitting and valves in order to monitor for mechanical integrity. Spoke to Wes Harmon over the phone and notified him of the violations. Notified Wes Harmon of violations by phone. |
2137846191 | 2014-01-21 | Surface Facility Construction | No Violations | Injection line test. Installed 3 Fiber Spar injection line from the pump house (Roscoe Mills # 1 34-105-23619) to the well. One under ground connection was made near the Mills # 1 injection well. The remaining injection line is continuous. The injection line was filled with fresh water and tested to 1380 psi for 15 minutes with no loss in pressure. While monitoring the gauge at the surface facility The master valve at the well was opened and the injection line pressure was observed to drop to zero. |
269259632 | 2019-6-5 0:00:0 | SW | No Violations | 0.50 |
324141076 | 2017-3-10 0:00: | SW | No Violations | 1.00 |
356074292 | 2016-3-16 0:00: | SW | No Violations | |
44916739 | 2015-9-1 0:00:0 | SW | No Violations | 1.50 |
506440311 | 2014-2-27 0:00: | SW | No Violations | 8.00 |
54234083 | 2014-10-15 0:00 | SW | No Violations | 1.00 |
616791392 | 2014-11-3 0:00: | SW | No Violations | 1.00 |
617771301 | 2017-2-21 0:00: | SW | No Violations | 1.00 |
64059656 | 2017-11-16 0:00 | SW | No Violations | 0.30 |
677102450 | 2020-7-23 0:00: | SW | No Violations | 1.00 |
911679806 | 2016-10-18 0:00 | SW | No Violations | 0.50 |
963200527 | 2019-11-7 0:00: | SW | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0356074292 | US-OH-123745 | 2016-04-04 | Failure to file salt water injection annual report | |
0506440311 | US-OH-125527 | 2014-04-10 | Pollution/Contamination | |
1102044127 | US-OH-102486 | 2018-03-21 | NONE | Failure to report disposal fees |
1393550350 | US-OH-111620 | 2014-04-10 | Failure to notify inspector before starting injection | |
1476727620 | US-OH-113637 | 2016-11-23 | Pollution/Contamination | |
2117246597 | US-OH-121684 | 2014-10-01 | Violation of injection tubing/fitting requirements |
For data sources see[9]