Well Details

Well ID: 34-105-23652
Loading map...
Country: United States
State: Ohio
County: Meigs
Municipality: Lebanon Township
Operator Name: ROSCOE MILLS JR TRUST
Well Pad ID:
Farm/Lease Name: MILLS ROSCOE (SWIW #21)
License Status: Active Injection
License Date: 2013-12-20
Spud Date: 2009-09-30
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2009-10-07
Well Total Depth: 5835.00 ft
Configuration: Vertical
Latitude: 38.930000
Longitude: -81.780000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-02-20 Proposed Formations:NEWBURG, CLINTON, MEDINA, Issued Date:2/20/2009, Expired Date:2/20/2010 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2009-10-07
Completion Report Received 2009-12-16
Change of Owner 2013-08-21 Operator changed from 490, HILL DAVID R INC to 8272, MILLS ROSCOE
Annulus Pressure Monitoring Approved 2013-10-09
APP 2013-12-20 Proposed Formations:CLINTON, Issued Date:12/20/2013, Expired Date:12/20/2015 12:00:00 PM, Drilling unit acres:50, Proposed Well Type:SWD, Proposed Well Class:SWIW
Last Compliance Report 2014-02-14
Construction Permit Expires 2015-12-20
Change of Owner 2016-08-03 Operator changed from 8272, MILLS ROSCOE to 9731, ROSCOE MILLS JR TRUST
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-02-19 5593 5656 76
5593 5656 76
5593 5656 76

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 79000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 DAVID R HILL INC 733.00 0.00 15
2010 DAVID R HILL INC 6825.00 0.00 365
2011 DAVID R HILL INC 4897.00 0.00 365
2012 DAVID R HILL INC 4897.00 0.00 366
2013 DAVID R HILL INC 3342.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 DAVID R HILL INC Brine 0 15
2010 DAVID R HILL INC Brine 151 365
2011 DAVID R HILL INC Brine 92 365
2012 DAVID R HILL INC Brine 0 366
2013 DAVID R HILL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1060835555 2009-11-6 0:00: DD No Violations
-1079477400 2019-5-22 0:00: SW No Violations 1.00
-1081935178 2020-6-15 0:00: SW No Violations 1.00
-113345529 2018-8-22 0:00: SW No Violations 0.50
-1194780916 2018-11-5 0:00: SW No Violations 2.00
-1219320065 2018-12-11 0:00 SW No Violations 1.00
-1294796579 2014-1-2 0:00:0 SC No Violations 2.00
-1422353299 2014-2-20 0:00: SW No Violations 2.00
-1434134457 2019-7-18 0:00: SW No Violations 1.00
-146070768 2014-2-27 0:00: SW No Violations 8.00
-1528571756 2014-10-20 0:00 SW No Violations 1.00
-1626691300 2019-4-9 0:00:0 SW No Violations 0.50
-1637404941 2015-2-26 0:00: SW No Violations 3.20
-1792643094 2015-2-23 0:00: SW No Violations 1.00
-1798700790 2014-8-26 0:00: SW No Violations 1.50
-1889847227 2019-4-17 0:00: SW No Violations 2.50
-2086414910 2013-10-15 0:00 PW No Violations 3.00
-26957590 2014-6-17 0:00: SW No Violations 1.50
-324702917 2014-12-4 0:00: SW No Violations 1.50
-401003955 2015-5-13 0:00: SW No Violations 1.50
-468917344 2020-2-19 0:00: SW No Violations 1.00
-501480068 2019-2-7 0:00:0 SW No Violations 0.70
-553401678 2019-6-10 0:00: SW No Violations 1.00
-568667521 2019-12-9 0:00: SW No Violations 0.50
-583138494 2015-5-14 0:00: SW No Violations 4.50
-687907736 2017-8-29 0:00: SW No Violations 2.40
-75808506 2018-3-26 0:00: SW No Violations 2.00
-774757336 2015-11-24 0:00 SW No Violations 1.00
-79709946 2019-1-7 0:00:0 SW No Violations 0.70
-860667344 2015-5-12 0:00: SW No Violations 1.50
-878693094 2014-9-2 0:00:0 SW No Violations 3.00
-903796160 2017-6-28 0:00: SW No Violations 1.40
-982301935 2019-12-24 0:00 SW No Violations 0.50
0026957590 2014-06-17 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Good identification at the wellhead.
0044916739 2015-09-01 Salt Water Injection Well No Violations Inspected the Mills API# 3410523619 facility, injection pump, injection pressure and annulus pressure.
0054234083 2014-10-15 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted at well.
0064059656 2017-11-16 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 360 psi on the annulus and 1140 psi on the injection tubing. The well has a legible identification.
0075808506 2018-03-26 Salt Water Injection Well No Violations The salt water injection well had 360 psi on the injection tubing and 55 psi on the annulus. The dike was free of fluids. Legible identification was posted.
0079709946 2019-01-07 Salt Water Injection Well No Violations Inspected the Mills surface facility, injection pressure and annulus pressure. Identification is posted.
0112760287 2013-10-07 Production Wells No Violations Authorization to run an injectivity test was granted on 9-12-2013 expires on 10-13-13. Witnessed new Baker Hughes A3 LOK Set Packer with ON /OFF Tool ran with new 2 3/8 4.7 lb tubing. Packer ran to 5532.65 (center of element). Packer was not set. Waiting on pump truck to set packer. Scheduled for 10-9-13.
0113345529 2018-08-22 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification is posted.
0139860596 2013-10-10 Production Wells No Violations Authorization to run an injectivity test was granted on 9-12-2013 expires on 10-13-13. 1200 psi injection pressure. Mud pump had multiple leaks and had to be shut down to repair the leaks. Injection resumed after repairs were made and 4 hose was replaced.
0146070768 2014-02-27 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 506440311 Inspection of the well site during the initial injection revealed a brine contaminated area extending 30 feet by 20 feet from the wellhead. The well casing had salt crystals and the wellhead ring contained brine. A field test of the contaminated soil with a High Range Quantab revealed a Chloride level over 6508 ppm Cl (highest level of the Quantab). Another High Range Quantab was placed in the brine on the wellhead it revealed a Chloride level over 6508 ppm Cl (highest level of the Quantab). I called the South West Region Supervisor and was told to collect 2 soil samples from the contaminated area and 1 control sample. I also collected a brine sample from the brine pooled on the wellhead. The samples were taken to the ODNR Lab. Wes Harmon and Rick Zickefoose (both from Green Hunter Water) were told on site to remove the contaminated soil. The contaminated soil must be hauled to an approved EPA landfill for disposal.
0148689753 2017-01-17 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Inspected the Mills surface facility.
0324141076 2017-03-10 Salt Water Injection Well No Violations Inspected the Mills Facility 34-105-23619, injection pressure and annulus pressure. Identification posted.
0324702917 2014-12-04 Salt Water Injection Well No Violations Inspected the injection pressure, annulus pressure, and the surface facility of #34-105-23619 Mills # 2.
0356074292 2016-03-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED
0401003955 2015-05-13 Salt Water Injection Well No Violations Inspected the Mills #1 facility, Injection pressure and annulus pressure.
0501480068 2019-02-07 Salt Water Injection Well No Violations Inspected the Mills surface facility, injection pressure and annulus pressure. Identification is posted.
0506440311 2014-02-27 Salt Water Injection Well Violations Noted Inspection of the well site during the initial injection revealed a brine contaminated area extending 30 feet by 20 feet from the wellhead. The well casing had salt crystals and the wellhead ring contained brine. A field test of the contaminated soil with a High Range Quantab revealed a Chloride level over 6508 ppm Cl (highest level of the Quantab). Another High Range Quantab was placed in the brine on the wellhead it revealed a Chloride level over 6508 ppm Cl (highest level of the Quantab). I called the South West Region Supervisor and was told to collect 2 soil samples from the contaminated area and 1 control sample. I also collected a brine sample from the brine pooled on the wellhead. The samples were taken to the ODNR Lab. Wes Harmon and Rick Zickefoose (both from Green Hunter Water) were told on site to remove the contaminated soil. The contaminated soil must be hauled to an approved EPA landfill for disposal.
0583138494 2015-05-14 Salt Water Injection Well No Violations Witnessed an acid stimulation by Producers Service Co.
0616791392 2014-11-03 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, and checked injection pressure and annulus pressure.
0617771301 2017-02-21 Salt Water Injection Well No Violations Inspected the Mills Surface Facility 34-105-23619, injection pressure and annulus pressure. Identification posted.
0687907736 2017-08-29 Salt Water Injection Well No Violations My inspection today revealed the injection well has 470 PSI on the annulus and 5 PSI on the injection tubing. Legible identification was posted. No violations noted.
0774757336 2015-11-24 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted. Inspected the Mills Facility 3410523619.
0860667344 2015-05-12 Salt Water Injection Well No Violations Inspected the Mills #1 Surface Facility. The Murphy pressure cut off switch on the injection pump for the Mills #2 was set at 1370 psi. I told Wes Harmon to set it at the max injection pressure of 1290 psi. Inspected the injection pressure and annulus pressure. Identification was posted at the well site.
0878693094 2014-09-02 Salt Water Injection Well No Violations Acid treatment. Producers Service Corp. Pumped 2000 gallons of 28% HCL. Inspected the containment dike, tanks, injection pump, unloading pad, injection pressure and annulus pressure.
0903796160 2017-06-28 Salt Water Injection Well No Violations Salt water injection well inspection. The annulus pressure was 441 psi, the injection tubing pressure was 353 psi. No violations were noted during my inspection.
0911679806 2016-10-18 Salt Water Injection Well No Violations Compliance Notice # 1476727620 follow up inspection. The leak has been repaired. Wellhead has been cleaned up and painted. No leaks observed.
1060835555 2009-11-06 Drill / Deepen / Reopen No Violations Kilbarger service rig is on location. Drill pit has been closed. Mud pit is being used by service rig. No problems observed during inspection.
1102044127 2018-02-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. REPORTS RECEIVED BY THE DIVISION ON FEBRUARY 26, 2018
112760287 2013-10-7 0:00: PW No Violations 11.00
1173837769 2013-10-09 Production Wells No Violations Authorization to run an injectivity test was granted on 9-12-2013 expires on 10-13-13. New Baker Hughes A3 LOK Set Packer with ON /OFF Tool ran with new 2 3/8 4.7 lb tubing. Packer ran to 5532.65 (center of element). Packer set with 5000 lbs compression. Tubing was released after setting the packer and fresh water with inhibitor was pumped through the tubing and circulated to a tank at the surface. Pumped 80.2 barrels fresh water with 10 gallons inhibitor. Sting tubing back onto packer and pressure up the tubing to 2257 psi to open the disk in packer. When disk was removed the tubing pressure went to vacuum. Tested annulus at 1360 psi for 15 minutes with a loss of 60 psi. Started injectivity test at 3:15 pm.
1194780916 2018-11-05 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification is posted.
1219320065 2018-12-11 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification is posted.
1243408115 2018-09-28 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification is posted.
1294796579 2014-01-02 Surface Facility Construction No Violations Meet on location with Roscoe Mills, John Jack (Green Hunter) and Contractor to review injection line installation and proposed route including utilizing an existing 7 steel conduit that runs under Route 33. Installation of a centralizer or other form of barrier between the Fiber spar Injection line and the 7 steel conduit was discussed.
1315224135 2016-07-07 Salt Water Injection Well No Violations Inspected the Mills Surface facility, injection pump, injection pressure and annulus pressure. Identification posted.
1317834954 2011-10-05 Preliminary Restoration No Violations Pits have been filled and the area graded and seeded with good vegetative cover and no erosion. Preliminary Restoration passed.
1332837059 2018-03-05 Salt Water Injection Well No Violations The salt water injection well had 372 psi on the injection tubing and 174 psi on the annulus. The well has a legible identification.
1340188238 2020-1-14 0:00: SW No Violations 8.70
1378746221 2013-09-09 Completion Testing No Violations Witnessed 500 gallons 15% HCl being spot to perforations. Pressure and rate recorded.
1386771723 2013-12-09 Production Wells No Violations Request for inspection from Andrew Adgate ODNR DOGRM Geologist UIC Section. Site evaluation for salt water injection well permit. Located and collected GPS coordinates on Water wells within close proximity to the proposed injection well. 1st water well at Roscoe Mills residence N38.93013 / W 081.78795, 957 feet from the proposed injection well. 2nd water well N38.93076 / W081.78745, 747 feet from the proposed injection well. 3rd water well N38.93464 / W081.79388, 1757 feet from the proposed injection well. 4th water well N38.93140 / W081.78984, 681 feet from the proposed injection well. 5th water well N38.935704 / W081.78835, 2056 feet from the proposed injection well. The Ohio River is 1365 feet South West of the proposed injection well.
1393550350 2014-02-27 Salt Water Injection Well Violations Noted Convert to Salt Water Injection Well Permit Issued on 12-20-13. Permit and Constructional Conditions Number 4. State that the Mineral Resources Inspector must be notified at a minimum of 48 hours in advance of the time of initial injection so that a representative of the Division can be present to witness the operations. I was notified by Wes Harmon (Green Hunter Water) on 2-26-14 at 2:09 pm that they received the Chiefs Order to inject. Wes wanted me to come to the site on 2-26-14. I told Wes that I was currently in Vinton County and could not come to the well on 2-26-14. I said that I could be there first thing in the morning on 2-27-14. At 3:49 pm. On 2-26-14 I received a voice message from John Jack (Green Hunter Water) That said that they are going to start injection tonight 2-26-14. I responded (as soon as I had a clear cell signal) that The permit conditions require 48 hours notice. I did again offer to be at the well on 2-27-14 in the morning. I received no other messages in regards to the issue until 8:11 am on 2-27-14 when Wes Harmon called and asked if I was coming to the well. I arrived at the surface facility at 9:40 am on 2-27-14. The pumps were off and I was told that they did inject 300 barrels on 2-26-14.
1394035819 2014-03-05 Salt Water Injection Well No Violations Compliance Notice Follow Up to Compliance Notice Issued on 2-27-14. Well site is snow covered. Wes Harmon (Green Hunter Water) told me that they removed approximately 8 tons of soil from the location. The soil was placed in a roll off dumpster and taken to landfill. Well site is graded. No leaks were observed on the injection line, or injection tubing. Injection psi during inspection was 1220 psi. I told Wes Harmon and Roscoe Mills that they need identification at the wellhead and the surface facility. Currently there is identification at the 100 barrel production tank beside the lease road. This tank and equipment are not part of the injection operations.
1394554744 2014-03-11 Salt Water Injection Well No Violations Witnessed injectivity test at well. Pressures and rates recorded. 1000 gallons of 15% HCl displaced to perforations with 12 Barrels (Bbl) filtered brine. Allowed to set for 30 minutes, and then another 1000 gallons 15% HCl displaced with another 68 bbl filtered brine. Total volume used 119 Bbl, at an average rate of 1.4 Bbl/minute. Average psi of treatment was 1270, with an Instantaneous Shut-in pressure of 1006 psi and a 5 minute shut-in of 943 psi. the pressure on the annulus was measured at 480 psi after the treatment.
139860596 2013-10-10 0:00 PW No Violations
1404149332 2014-06-30 Salt Water Injection Well No Violations Follow up to 2117246597. Fittings replaced.
1412607460 2014-10-06 Salt Water Injection Well No Violations Inspected the injection pressure, and annulus pressure. Identification posted on wellhead.
1416143396 2016-03-02 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd, & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016.REPORTS RECEIVED 3/8/2016.
1418756719 2014-12-16 Salt Water Injection Well No Violations Inspected the injection pressure, annulus pressure and the surface facility at the Mills # 1 API #34-105-23619.
1420829955 2015-01-09 Salt Water Injection Well No Violations Inspected the injection well site, checked the injection pressure and annulus pressure. Inspected the Mills # 1 surface facility. Checked the containment dike, tanks, injection pumps, and unloading pads.
1422353299 2014-02-20 Salt Water Injection Well No Violations Inspected status of the well. Currently annulus is pressurized and injection line is connected to the Mills # 1 surface facility. Injection line valves are closed.
1428926672 2015-04-09 Surface Facility Construction No Violations On site meeting with Green Hunter and UIC Section staff. Discussed proposed additions to facility and pipelines to proposed injection wells.
1434563617 2015-06-17 Salt Water Injection Well No Violations Inspected the surface facility of the Mills # 1 and 2. Witnessed brine trucks unloading on the pad. Inspected the injection pressure and annulus pressure. Identification posted at the well and on the facility access road.
1437464960 2016-05-23 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted. The entrance to the access road was blocked off with a metal tank ladder and a 6 steel pipe.
1445604518 2015-10-21 Salt Water Injection Well No Violations Inspected the Mills Facility API# 34-105-23619. Inspected the injection pressure and annulus pressure. Wes Harmon was on site and we discussed the corroded 2 tee with salt build up on the injection tubing. Wes said that they will replace the fittings.
1460020401 2014-07-21 Salt Water Injection Well No Violations Inspected the injection pressure, annulus pressure, containment dike, tanks, injection pump, and the unloading pad. Good identification at the well. Containment dike is free of fluids.
1476727620 2016-10-17 Salt Water Injection Well Violations Noted Inspected the Mills surface facility 3410523619. Inspected the injection pressure and annulus pressure. A small seep was observed on the injection line connecting to the injection tubing. A 4 inch nipple connecting two tees has evidence of a leak with salt build up on the lower fittings and wellhead. Wes Harmon was contacted about the seep. Wes sent a crew to repair the seep.
148689753 2017-1-17 0:00: SW No Violations 1.00
1524948225 2014-02-27 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 1393550350 Convert to Salt Water Injection Well Permit Issued on 12-20-13. Permit and Constructional Conditions Number 4. State that the Mineral Resources Inspector must be notified at a minimum of 48 hours in advance of the time of initial injection so that a representative of the Division can be present to witness the operations. I was notified by Wes Harmon (Green Hunter Water) on 2-26-14 at 2:09 pm that they received the Chiefs Order to inject. Wes wanted me to come to the site on 2-26-14. I told Wes that I was currently in Vinton County and could not come to the well on 2-26-14. I said that I could be there first thing in the morning on 2-27-14. At 3:49 pm. On 2-26-14 I received a voice message from John Jack (Green Hunter Water) That said that they are going to start injection tonight 2-26-14. I responded (as soon as I had a clear cell signal) that The permit conditions require 48 hours notice. I did again offer to be at the well on 2-27-14 in the morning. I received no other messages in regards to the issue until 8:11 am on 2-27-14 when Wes Harmon called and asked if I was coming to the well. I arrived at the surface facility at 9:40 am on 2-27-14. The pumps were off and I was told that they did inject 300 barrels on 2-26-14.
1525700502 2018-05-03 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted. Accompanied by UIC Geologist.
1528571756 2014-10-20 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted at well.
1572620674 2020-4-6 0:00:0 SW No Violations 1.00
1573155057 2019-10-30 0:00 SW No Violations 1.00
1579611297 2020-1-8 0:00:0 SW No Violations 6.50
1599240054 2016-12-14 Salt Water Injection Well No Violations Inspected the Mills Surface Facility (34-105-23619), Injection pressure and annulus pressure. Identification posted.
1626691300 2019-04-09 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification is posted.
1637404941 2015-02-26 Salt Water Injection Well No Violations Witnessed acid job on the Roscoe Mills #2. 1000 gallons of HCl were displaced through the tubing at 5532 feet and allowed to sit for 1/2 hour, then another 500 gallons of HCl were displaced to the perfs and allowed to sit for 1/2 an hour, then another 500 gallons were displaced. A total of 200 gallons used for the job.
1717079268 2019-03-05 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. The annulus is frozen. Identification is posted. The 100 barrel production tank is still on the lease and appears to have fluid in it. A small wet area has formed on the tank at 30 inches off the ground with salt residue. I called Roscoe Mills Jr Trust phone number and left a message inquiring about the tank status.
1792643094 2015-02-23 Salt Water Injection Well No Violations Follow up on the repairs being made to the fire damaged unloading pad containment vault at the Roscoe Mills Surface facility 34-105-23619. The injection operations are shut down until the repairs are made to the vault. Excavation and removal of the damaged vault are on going. All fluids from the vault are being removed by a Roscoe Mills vacuum truck. Inspected the unloading pad, containment dike, tanks, injection pumps, injection pressure and annulus pressure.
1798700790 2014-08-26 Salt Water Injection Well No Violations Inspected the injection pressure, annulus pressure, injection line, injection pump, containment dike, and unloading pad. Identification posted at the well. A brine drip was observed on the 2 hammer union on the injection line. Another brine drip was observed at the 2 tee on top of the injection tubing. I talked to Wes Harmon (Green Hunter Water) about the brine drips. Wes is going to replace the fittings.
184168542 2019-5-9 0:00:0 SW No Violations 0.80
1889847227 2019-04-17 Salt Water Injection Well No Violations Inspected the Injection pressure and Annulus pressure. Identification is posted. A new 1/4 inch needle valve has been installed on the injection tubing.
2015554045 2018-04-30 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification is posted.
2037340176 2019-04-04 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted. The 100 barrel production tank located at GPS N38.93159/W081.78831 has been emptied by Harmon Well Services Brine truck.
2080856300 2015-06-02 Salt Water Injection Well No Violations Inspected the Mills surface facility 3619, injection pressure and annulus pressure.
2086414910 2013-10-15 Production Wells No Violations All equipment for the injectivity test has been removed from the location. Site has been graded. Well is located in a corn field and no grass seed or mulch has been applied to the affected area. Tubing pressure was 520 and annulus pressure was 325.
2117246597 2014-06-24 Salt Water Injection Well Violations Noted Fittings too corroded to test injection or annulus. Well shall be equipped with functioning fitting and valves in order to monitor for mechanical integrity. Spoke to Wes Harmon over the phone and notified him of the violations. Notified Wes Harmon of violations by phone.
2137846191 2014-01-21 Surface Facility Construction No Violations Injection line test. Installed 3 Fiber Spar injection line from the pump house (Roscoe Mills # 1 34-105-23619) to the well. One under ground connection was made near the Mills # 1 injection well. The remaining injection line is continuous. The injection line was filled with fresh water and tested to 1380 psi for 15 minutes with no loss in pressure. While monitoring the gauge at the surface facility The master valve at the well was opened and the injection line pressure was observed to drop to zero.
269259632 2019-6-5 0:00:0 SW No Violations 0.50
324141076 2017-3-10 0:00: SW No Violations 1.00
356074292 2016-3-16 0:00: SW No Violations
44916739 2015-9-1 0:00:0 SW No Violations 1.50
506440311 2014-2-27 0:00: SW No Violations 8.00
54234083 2014-10-15 0:00 SW No Violations 1.00
616791392 2014-11-3 0:00: SW No Violations 1.00
617771301 2017-2-21 0:00: SW No Violations 1.00
64059656 2017-11-16 0:00 SW No Violations 0.30
677102450 2020-7-23 0:00: SW No Violations 1.00
911679806 2016-10-18 0:00 SW No Violations 0.50
963200527 2019-11-7 0:00: SW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0356074292 US-OH-123745 2016-04-04 Failure to file salt water injection annual report
0506440311 US-OH-125527 2014-04-10 Pollution/Contamination
1102044127 US-OH-102486 2018-03-21 NONE Failure to report disposal fees
1393550350 US-OH-111620 2014-04-10 Failure to notify inspector before starting injection
1476727620 US-OH-113637 2016-11-23 Pollution/Contamination
2117246597 US-OH-121684 2014-10-01 Violation of injection tubing/fitting requirements

For data sources see[9]