X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-105-23060

Well Details

Well ID: 34-105-23060
Loading map...
Country: United States
State: Ohio
County: Meigs
Municipality: Chester Township
Operator Name: J D DRILLING COMPANY
Well Pad ID:
Farm/Lease Name: JESSIE WEBER
License Status: Producing
License Date: 2013-02-19
Spud Date: 1984-08-04
Spud Drilling Contractor:
Final Drill Date: 1984-08-07
Well Total Depth: 3800.00 ft
Configuration: Vertical
Latitude: 39.080000
Longitude: -81.900000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-03-16 116 J D DRILLING CO GeoDate 3/16/84
Oil and Gas 1984-03-16 Issued Date 3/16/84 Expired Date 9/12/84 Acres 0040000 Tool Type RTA Proposed Formation OHIO SHALE Proposed Depth 03800 Proposed Drill Depth 03800
Original Spud 1984-08-04 DD 8-31-85
Completed 1984-08-07 DD 8-31-85
Reached Total Depth 1984-08-07 DD 8-31-85
Completion Report Received 1984-08-31 DD 8-31-85
CO 1985-08-27 116 J D DRILLING CO GeoDate 8/27/85
Oil and Gas 1985-08-27 Issued Date 8/27/85 Expired Date 8/27/86 Acres 0040000 Tool Type RTA Proposed Formation ORISKANY Proposed Depth 00000 Proposed Drill Depth 00000
APP 2013-02-19 Proposed Formations:OHIO SHALE, Issued Date:2/19/2013, Expired Date:2/19/2015 12:00:00 PM, Drilling unit acres:130, Proposed Well Type:SWD, Proposed Well Class:SWIW
Last Compliance Report 2015-02-12 DD 8-31-85
Construction Permit Expires 2015-02-19 DD 8-31-85
Record Last Modified 2017-07-06 DD 8-31-85

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3050 3785 2
3050 3785 2
3050 3785 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0 1.2 MILLION GAS FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 J D DRILLING COMPANY 889.00 0.00 325
1986 J D DRILLING COMPANY 4106.00 0.00 365
1987 J D DRILLING COMPANY 5136.00 0.00 365
1988 J D DRILLING COMPANY 3078.00 0.00 365
1989 J D DRILLING COMPANY 3434.00 0.00 365
1990 J D DRILLING COMPANY 2701.00 0.00 365
1991 FREDEBAUGH WELL DRLG CO 26.00 0.00 365
1992 J D DRILLING COMPANY 1796.00 0.00 365
1993 J D DRILLING COMPANY 1956.00 0.00 365
1994 J D DRILLING COMPANY 2152.00 0.00 365
1995 J D DRILLING COMPANY 2243.00 0.00 360
1996 J D DRILLING COMPANY 1968.00 0.00 365
1997 J D DRILLING COMPANY 2052.00 0.00 365
1998 J D DRILLING COMPANY 2143.00 0.00 365
1999 J D DRILLING COMPANY 1621.00 0.00 365
2000 J D DRILLING COMPANY 1520.00 0.00 365
2001 J D DRILLING COMPANY 1936.00 0.00 365
2002 J D DRILLING COMPANY 1592.00 0.00 365
2003 J D DRILLING COMPANY 853.00 0.00 365
2004 J D DRILLING COMPANY 887.00 0.00 365
2005 J D DRILLING COMPANY 1060.00 0.00 365
2006 J D DRILLING COMPANY 913.00 0.00 365
2007 J D DRILLING COMPANY 807.00 0.00 365
2008 J D DRILLING COMPANY 854.00 0.00 365
2009 J D DRILLING COMPANY 573.00 0.00 365
2010 J D DRILLING COMPANY 0.00 0.00 365
2011 J D DRILLING COMPANY 50.00 0.00 0
2012 J D DRILLING COMPANY 0.00 0.00 0
2013 J D DRILLING COMPANY 0.00 0.00 0
2015 J D DRILLING COMPANY 0.00 0.00 365
2016 J D DRILLING COMPANY 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 J D DRILLING COMPANY Brine 35 325
1986 J D DRILLING COMPANY Brine 142 365
1987 J D DRILLING COMPANY Brine 0 365
1988 J D DRILLING COMPANY Brine 46 365
1989 J D DRILLING COMPANY Brine 0 365
1990 J D DRILLING COMPANY Brine 0 365
1991 FREDEBAUGH WELL DRLG CO Brine 72 365
1992 J D DRILLING COMPANY Brine 0 365
1993 J D DRILLING COMPANY Brine 0 365
1994 J D DRILLING COMPANY Brine 83 365
1995 J D DRILLING COMPANY Brine 0 360
1996 J D DRILLING COMPANY Brine 55 365
1997 J D DRILLING COMPANY Brine 365
1998 J D DRILLING COMPANY Brine 365
1999 J D DRILLING COMPANY Brine 365
2000 J D DRILLING COMPANY Brine 365
2001 J D DRILLING COMPANY Brine 55 365
2002 J D DRILLING COMPANY Brine 0 365
2003 J D DRILLING COMPANY Brine 0 365
2004 J D DRILLING COMPANY Brine 0 365
2005 J D DRILLING COMPANY Brine 30 365
2006 J D DRILLING COMPANY Brine 0 365
2007 J D DRILLING COMPANY Brine 0 365
2008 J D DRILLING COMPANY Brine 0 365
2009 J D DRILLING COMPANY Brine 0 365
2010 J D DRILLING COMPANY Brine 0 365
2011 J D DRILLING COMPANY Brine 0
2012 J D DRILLING COMPANY Brine 0 0
2013 J D DRILLING COMPANY Brine 0 0
2015 J D DRILLING COMPANY Brine 0 365
2016 J D DRILLING COMPANY Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1380627711 2017-9-25 0:00: PW No Violations 1.00
-1462797698 2014-11-19 0:00 SW No Violations 2.50
-1769428270 2015-2-10 0:00: AM No Violations
-243391034 2015-5-7 0:00:0 PW No Violations 10.50
-286842022 2015-2-5 0:00:0 PW No Violations 2.60
-588108379 2015-1-7 0:00:0 SW No Violations 1.00
-760458959 2016-2-29 0:00: PW No Violations 1.00
0050129682 2015-11-18 Production Wells No Violations Conversion to salt water injection well. Tubing and packer have been removed from the well. Two joints of tubing were installed to lock the wellhead in. Valve was installed on the tubing. The remaining tubing has been loaded on a truck. A load of water was taken from the lined pit and taken to the Conroy SWIW facility.
0128707739 2015-02-12 Production Wells No Violations Tripping packer into hole to be set in accordance with the permit variance specifications.
0243391034 2015-05-07 Production Wells No Violations Convert to salt water injection well. Ran used 2 3/8 tubing and rebuilt Halliburton R-4 packer set at 2914. Packer had three shear pins installed. Pulled 28,000 lbs. tension. Filled annulus with fresh water and inhibitor. Annulus water level continued to drop and work air out of annulus. Company decided to shut in wellhead and install master valve on tubing and resume filling annulus on 5-8-15.
0268086441 2015-05-04 Production Wells No Violations Conversion to salt water injection well. Service rig is on the well. Company tried a new tool to attempt to fix the sharp area that has been cutting the rubber element on the packers. The new tool was to large to fit in the casing. Tool has been taken back for more machining.
0286842022 2015-02-05 Production Wells No Violations Witnessed partial injection well conversion operations. The well is being swabbed in order to determine depth of the potential holes in the production casing.
0588108379 2015-01-07 Salt Water Injection Well No Violations Conversion to salt water injection well. Service rig is on the well. Company crew were not on site. Currently waiting on down hole camera.
0760458959 2016-02-29 Production Wells No Violations Compliance Notice # 1446813527 follow up inspection. Wellhead is assembled with a master valve on the tubing (closed). Service rig has been moved from location. One 210 barrel tank on skids is on site and empty.
0839362490 2015-11-17 Production Wells No Violations Convert to salt water injection well. The parted tubing at 2469 was retrieved with an over shot tool. The company pulled two joints of tubing and then shut in the well.
0940905359 2016-05-25 Production Wells No Violations Compliance Notice # 1446813527 follow up inspection. The well has not been converted to an injection well. The well is equipped with a master valve on the tubing (shut off). The well is not connected to production equipment.
1228069340 2006-06-23 Production Wells No Violations There were no violations at the time of inspection.
1229385970 2014-09-18 Salt Water Injection Well No Violations Convert to saltwater injection well. Company service rig is installing a Halliburton R-4 Packer (rebuilt) and 2992 of 2 3/8 Tubing. Packer set at 2995. Filled annulus with 32 barrels fresh water and 1 gallon inhibitor.
128707739 2015-2-12 0:00: PW No Violations 2.00
1356036715 2012-12-19 Production Wells No Violations Site evaluation for a Conversion to Salt Water Injection Well Permit. Well is located on the top of a rolling hill top. Located with in a hay field. Well has identification. Well is disconnected from production equipment and production line. A 100 barrel steel tank is on site. A 1/2 mile radius search for water wells revealed: 4 wells: 307804, 275656,265603 and 289145. 307804 is 1245 feet South West of the proposed injection well. 275656 is 1617 feet South West of the proposed injection well. 265603 is 1577 feet North West of the proposed injection well. 289145 is 2873 feet South East of the proposed injection well. A pond is located 1085 feet to the South West of the proposed injection well.
1380627711 2017-09-25 Production Wells No Violations
1409065132 2014-08-26 Salt Water Injection Well No Violations Conversion to salt water injection well. Service rig is on the well. Pulled 99 joints of tubing from the well. Currently waiting in a new cable for the service rig.
1410354281 2014-09-10 Salt Water Injection Well No Violations Appalachian Well Surveys wire line on site to perforate the production casing 3802 to 3792 (20 shots) 3772 to 3732 (80 shots).
1411484988 2014-09-23 Salt Water Injection Well No Violations Mechanical integrity test. Tested annulus at 760 psi for 15 minutes. Total loss in 15 minutes was 15 psi. Packer is set at 2995
1412619585 2014-10-06 Salt Water Injection Well No Violations Convert to salt water injection well. Well is not connected to injection line or injection facility. Checked the annulus pressure and it was on a slight vacuum then equalized to zero psi. Injection tubing has a master valve that is closed. I contacted Jonathan Reese and told him that the annulus had a slight vacuum and that they need to fill the annulus with fresh water and test the annulus. Jonathan said they will do that and schedule a test.
1413299095 2014-10-14 Salt Water Injection Well No Violations (Inspection on 10-6-14 revealed slight vacuum then zero pressure on the annulus.) Filled annulus to surface with 12 gallons fresh water and attempted to test the annulus, Annulus would not pressure up past 700 psi and would drop off while the test pump was running to 80 psi and stay at 80 psi. The pressure was let off the annulus and an attempt to fill the annulus was attempted. The annulus was full to the surface. Another attempt was made to test the annulus. The second test had the same results. Pressure would not go above 700 and would drop off while the test pump was running. Multiple gauges were used during this process. No leaks were observed on the tubing or wellhead. Tubing pressure was on vacuum during the entire test. The injection tubing is not connected to an injection line. The injection line has not been installed to the well at this time. Jonathan Reese is going to move their service rig back on the well as soon as possible.
1413818729 2014-10-20 Salt Water Injection Well No Violations Canceled service rig for today. Company did not call and inform me that they were not going to move the rig today. The work on the packer has been rescheduled.
1414086859 2014-10-23 Surface Facility Construction No Violations Installing injection line from the Conroy salt water injection well. Service rig has been moved on location to work on the packer and tubing.
1414502646 2014-10-28 Salt Water Injection Well No Violations Service rig pulled 10,000 lbs. over string weight and filled annulus with 20 gallons fresh water. Was only able to pressure up to 520 psi and then the pressure would decline steady. The annulus test was attempted twice and then the decision was made to release the packer and trip the packer and tubing out of the well. The injection tubing is not connected to the new injection line from the Conroy surface facility.
1414599884 2014-10-29 Salt Water Injection Well No Violations Witness rebuilt Halliburton R-4 packer (with 3 shear pins installed) and 2 3/8 tubing being installed in the well. Set packer at 2964. Pulled tubing tension 6,000lbs over string weight. Filled annulus with fresh water and inhibitor. Unable to fill annulus, attempted multiple times to reset packer and pull more tension. None of the efforts resulted in a good pressure test of the annulus. Spence Carpenter decided to release the packer and pull the packer and tubing out of the well.
1414689487 2014-10-30 Salt Water Injection Well No Violations Witness new Parmaco packer and 2/38 tubing (2064 new, and 900 used ) Packer set at 2964(pulled 15,000 lbs. over string weight). Filled annulus with 32 barrels fresh water and inhibitor. Was unable to fill annulus, the fluid level dropped at a steady rate. Released packer and pulled up one joint of tubing reset packer and currently filling annulus with fresh water. Test is scheduled for 10-31-14.
1415123650 2014-11-04 Salt Water Injection Well No Violations Company ran a casing scraper inside the 4.5 casing on 11-3-14. Witnessed a rebuilt Parmaco packer (same packer that was installed new in this well on 10-30-14. The rubber element was replaced) and new 2 3/8 R-2, 10 round tubing being ran in the well. Packer set at 2951. MIT scheduled for 11-6-14.
1416240047 2014-11-13 Salt Water Injection Well No Violations Witnessed the Haliburton G-6 packer ran into hole and set at 2954 feet. Corrosion inhibitor and 32 bbl fresh water used to fill annular space. Annular space would not hold fluid, packer unset, two joints pulled and reset. Annulus still unable to hold fluuids. Tubing and packer pulled.
1421770647 2015-01-20 Production Wells No Violations Conversion to Salt water injection well. Appalachian well surveys ran a downhole camera. They were unable to see below the fluid level at 1180 feet. The camera was extracted from the 4.5 casing. The wellhead was shut in and the tubing was collar locked with a valve installed on the top. All valves were closed. Company is evaluating remedial options at this time.
1423165060 2015-02-05 Production Wells No Violations Conversion to salt water injection well. JD Drilling service rig on the well. Gravity fed 35 barrels fresh water down the 4.5 casing to get fluid moving out of the perforations. Well went on vacuum for a brief time then went static. Company currently is running swab tools in 4.5 casing. They are connected from the wellhead to a vacuum truck with hoses. The objective of swabbing is to remove fluid to allow another attempt with a down hole camera and to try and determine where the area is located that is cutting the rubber elements on the packers. Met with Spence Carpenter and Jonathan Reese on site to go over the plans for converting this well.
1423764166 2015-02-12 Salt Water Injection Well No Violations Conversion to salt water injection well. Installed rebuilt Halliburton R-4 packer (3) and 2911 feet of 2 3/8 10 round tubing. Packer set at 2914 with 26,000 lbs. tension. Packer has 3 shear pins installed. Spence Carpenter had a cement bond log for this well. I told Spence to send a copy of the bond log to the UIC section along with his letter requesting a variance in the packer setting depth. Spence explained that the problem they were having with the packers being damaged was discovered at 2928 a collar had a sharp piece of steel that was cutting the rubber elements as they passed below it. They have ran a casing scraper and swab tools down the well multiple times and it seems that this piece of steel has been sent to the bottom of the casing. After setting the packer they filled the annulus with 31.5 barrels fresh water and 1 gallon inhibitor. Tested annulus at 800 psi for 15 minutes with no loss in pressure.
1439564811 2015-08-14 Production Wells No Violations Conversion to salt water injection well. Appalachian well surveys set bridge plug in 4.5: casing at 2590 feet. Shot 4 holes in 4.5 casing between 2584 feet and 2586 feet. C&J Energy Services cement pump truck and bulk truck on site to pump the cement squeeze job through perforations. Circulate water to surface prior to pumping gel and cement. Water circulated into a lined pit during the entire cement job. Wire line tagged top of cement wiper plug at 2475 feet.
1439820145 2015-08-17 Production Wells No Violations Convert to salt water injection well. Witnessed cement bond log by Appalachian Well Surveys. Tag top of cement wiper plug at 2426 inside 4.5 casing.
1441910207 2015-09-10 Production Wells No Violations Conversion to salt water injection well. JD Drilling service rig and water truck are on location. Tubing and packer have been extracted from the well. Well is shut in with one joint of tubing and a valve. Talked to Jonathan Reese and they are planning to replace the tubing and try to set the packer again. Packer job has not been scheduled.
1445618111 2015-10-23 Production Wells No Violations Convert to saltwater injection well. JD Drilling service rig is on the well. A truck is on site with a load of used tubing. Another stack of tubing is by the well. The lined pit has water in it and the liner is falling in in two places. I contacted Jonathan Reese and told him that the pit needs to be emptied.
1446813527 2015-11-05 Production Wells Violations Noted Permit to convert to salt water injection well issued 2-19-2013, Permit Expired 2-19-2015. OAC 1501:9-3-06 (L) operations shall continue with due diligence or the permit shall expire. The last witnessed attempt to set the packer and tubing was on 9-3-2015. The attempt was not successful and the tubing and packer were extracted from the well. JD Drilling has 30days to submit a plugging plan for the Jessie Weber # 1 to the UIC Section at ODNR/DOGRM, 2045 Morse Road, Building F2, Columbus, Ohio 43229-6693.
1447181467 2015-11-10 Production Wells No Violations Convert to salt water injection well. Inspected the rebuilt Haliburton R-4 packer and used 2 3/8 tubing. Ran tubing and packer to 1032(preliminary test of casing while tripping in the well). Set packer with 11,000 lbs. tension. Attempted to fill annulus with fresh water. Annulus would fill up to surface then drop back at a steady rate. Spence Carpenter and Jim Diddle decided to release the packer and let it hang in casing. Job has been rescheduled for 11-13-15.
1447418289 2015-11-12 Production Wells No Violations Convert to salt water injection well. Continued running the used 2 3/8 tubing and packer from 1032 (ran on 11-10-15) to 2550. Set the Halliburton R-4 (rebuilt) packer at 2550 with 20,000 lbs tension. Started filling the annulus with fresh water and inhibitor. Approximately 40 minutes after setting the packer and while filling the annulus, the 2 3/8 tubing jumped up at the surface. The rig weight indicator showed less weight than the entire tubing string. Company pulled 1536 of tubing out. The last joint of tubing had 1/2 of threads left on the joint. The threads broke off in a collar. Ran tools in the 4 1/2 casing and TD top of the parted tubing at 2469. Company is planning on retrieving the tubing and packer next week.
1462797698 2014-11-19 Salt Water Injection Well No Violations Service rig is on the well. Packer has been released.
1467392611 2016-06-29 Administrative Inspection No Violations Compliance Notice # 1446813527 follow up. Received notification by email that JD Drilling wants to change the well status from convert to saltwater injection well to production well.
1769428270 2015-02-10 Administrative Inspection No Violations Spence Carpenter called and told me that they have found the area in the casing that has been damaging the packers. He wants to install the packer and tubing on 2-12-15 and set the packer at 2928. I told Spence that they will need to request a variance to set the packer at 2928.
1983658772 2015-09-03 Production Wells No Violations Convert to salt water injection well. Witnessed a rebuilt Halliburton R-4 packer and used 2 3/8 tubing being installed in the 4.5 casing. Packer was set at 2917 with 26,000 lbs. tension. Variance was granted on 3-6-2015. The annulus took more than 31.5 barrels and was not filling up. Spence Carpenter decided to release the packer and pull it up to 2549. Packer was set at 2549 and an attempt was made to fill the annulus. The annulus fluid level was dropping at a steady rate. The well was shut in and an attempt will be made to fill the annulus on 9-4-15.
2004617703 2016-07-25 Production Wells No Violations JD Drilling crew on site installing gas line and gas meter. Connecting to the 2 3/8 inch tubing with a 2 inch production line.
2035893515 2014-11-26 Salt Water Injection Well No Violations Service rig on location. Halliburton R-6 packer and tubing have been pulled from the well. The lower rubber element was cut up. Spence Carpenter told me that they plan to run a down hole camera the 2nd week of December.
268086441 2015-5-4 0:00:0 PW No Violations 1.50
50129682 2015-11-18 0:00 PW No Violations 2.50
839362490 2015-11-17 0:00 PW No Violations 3.00
940905359 2016-5-25 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1446813527 US-OH-112981 2016-07-21 Well shall be plugged

For data sources see[9]