If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-105-22738 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.05,"lon":-82.09,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Meigs | |
Municipality: Salisbury Township | |
Operator Name: J D DRILLING COMPANY | |
Well Pad ID: | |
Farm/Lease Name: CLONCH LELAND & RETHA | |
License Status: Active Injection | |
License Date: 2006-04-12 | |
Spud Date: 2006-07-05 | |
Spud Drilling Contractor: D H F DRILLING | |
Final Drill Date: 2006-08-10 | |
Well Total Depth: 4395.00 ft | |
Configuration: Vertical | |
Latitude: 39.050000 | |
Longitude: -82.090000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1983-07-14 | 116 J D DRILLING CO GeoDate 7/14/83 |
Conversion to Injector | 1983-07-14 | |
Salt Water Injection Well | 1983-07-14 | Issued Date 7/14/83 Expired Date 1/10/84 Acres 0050000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04395 Proposed Drill Depth 04395 |
Storage Well | 1983-07-14 | Issued Date 7/14/83 Expired Date 1/10/84 Acres 0050000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04395 Proposed Drill Depth 04395 |
Original Spud | 1984-01-24 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
Completed | 1984-01-29 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
First Injection | 1984-04-01 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
CO | 1991-03-04 | 116 J D DRILLING CO GeoDate 3/4/91 |
Salt Water Injection Well | 1991-03-04 | Issued Date 3/4/91 Expired Date Acres 0050000 Tool Type RTA Proposed Formation MARCELLUS SH Proposed Depth Proposed Drill Depth |
Storage Well | 1991-03-04 | Issued Date 3/4/91 Expired Date Acres 0050000 Tool Type RTA Proposed Formation MARCELLUS SH Proposed Depth Proposed Drill Depth |
Annulus Pressure Monitoring Approved | 1992-07-01 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
CO | 1994-05-02 | 4807 OHIO BEAR INC GeoDate 3/4/91 |
CO | 1996-07-05 | 116 J D DRILLING CO GeoDate 3/4/91 |
APP | 1998-03-16 | Proposed Formations:OHIO SHALE, Issued Date:3/16/98, Expired Date:3/16/99 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:SWD, Proposed Well Class:SWIW |
APP | 2005-02-15 | Proposed Formations:OHIO SHALE, Issued Date:2/15/2005, Expired Date:2/15/2006 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:SWD, Proposed Well Class:SWIW |
APP | 2006-04-12 | Proposed Formations:OHIO SHALE, Issued Date:4/12/2006, Expired Date:4/12/2007 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Plugged Back | 2006-07-26 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
Reached Total Depth | 2006-08-10 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
Construction Permit Expires | 2007-04-12 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
Last Compliance Report | 2008-02-15 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
Completion Report Received | 2008-02-21 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
Record Last Modified | 2015-09-24 | CHG IN DEPTH/FORM 10-01-83, R.I. 3-20-98 PERMIT EXPIRED - INJECTION WELL PLUGGED BACK TO OHIO SHALE ON 7/26/06 - |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-06-06 | 2740 | 3040 | 82 |
2008-06-06 | 4279 | 4299 | 4 |
2740 | 3040 | 82 | |
4279 | 4299 | 4 | |
2740 | 3040 | 82 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 600 Gal | 0 | |||
H2O | 0 | 235 Bbl | 7500 | ACID |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1015311589 | 2006-8-10 0:00: | SW | No Violations | |
-1019772435 | 2006-5-17 0:00: | SW | No Violations | |
-1031969427 | 2004-2-5 0:00:0 | SW | No Violations | |
-1087055346 | 2018-10-15 0:00 | SW | No Violations | 1.00 |
-1117869689 | 2019-5-23 0:00: | SW | No Violations | 1.00 |
-1134615602 | 2011-10-25 0:00 | SW | No Violations | 2.50 |
-1248148422 | 2016-4-14 0:00: | SW | No Violations | 1.50 |
-1253271848 | 2003-3-5 0:00:0 | SW | No Violations | |
-1274758837 | 2014-10-7 0:00: | SW | No Violations | |
-1329981190 | 2015-6-2 0:00:0 | SW | No Violations | 2.00 |
-1496623811 | 2014-5-20 0:00: | SW | No Violations | 1.30 |
-1516547420 | 2014-12-16 0:00 | SW | No Violations | 1.00 |
-160658252 | 2016-10-27 0:00 | SW | No Violations | |
-1618094538 | 2013-1-18 0:00: | SW | No Violations | 1.50 |
-1618102059 | 2019-4-29 0:00: | SW | No Violations | |
-1649795380 | 2012-8-22 0:00: | SW | No Violations | 0.50 |
-1680881677 | 2005-6-16 0:00: | SW | No Violations | |
-1685942370 | 2008-12-3 0:00: | SW | No Violations | |
-1689183921 | 2007-9-10 0:00: | SW | No Violations | |
-1717519550 | 2018-3-14 0:00: | SW | No Violations | 0.40 |
-1743473294 | 2019-1-8 0:00:0 | SW | No Violations | 2.00 |
-1802200386 | 2016-12-20 0:00 | SW | No Violations | 1.00 |
-1942848369 | 2015-4-23 0:00: | SW | No Violations | 1.50 |
-1969404457 | 2018-9-18 0:00: | SW | No Violations | 1.00 |
-2142887619 | 2018-6-6 0:00:0 | SW | No Violations | 3.00 |
-216142501 | 2005-1-13 0:00: | SW | No Violations | |
-305957938 | 2019-8-5 0:00:0 | SW | No Violations | 1.00 |
-309365208 | 2013-10-28 0:00 | SW | No Violations | 1.00 |
-314250351 | 2011-3-8 0:00:0 | SW | No Violations | |
-403589900 | 2013-7-17 0:00: | SW | No Violations | 0.30 |
-458835377 | 2004-7-15 0:00: | SW | No Violations | |
-468537078 | 2014-2-20 0:00: | SW | No Violations | 0.70 |
-479986209 | 2006-6-27 0:00: | SW | No Violations | |
-492626496 | 2006-8-11 0:00: | SW | No Violations | |
-753672285 | 2006-7-31 0:00: | SW | No Violations | |
-760721356 | 2008-2-25 0:00: | SW | No Violations | |
-766873628 | 2016-7-18 0:00: | SW | No Violations | 1.20 |
-869167061 | 2019-3-7 0:00:0 | SW | No Violations | 1.00 |
-895875091 | 2006-3-29 0:00: | SW | No Violations | |
-954425920 | 2006-7-14 0:00: | SW | No Violations | |
-954425920193713 | 2006-7-14 0:00: | PB | No Violations | |
-954425920196463 | 2006-7-14 0:00: | SW | No Violations | |
-966095518 | 2005-5-6 0:00:0 | SW | No Violations | |
-97918536 | 2007-2-16 0:00: | SW | No Violations | |
-985386220 | 2003-7-11 0:00: | PW | No Violations | |
0000UIC119 | 1987-03-09 | Salt Water Injection Well | No Violations | 1501:9-3-07(E)&(F) |
0007890950 | 2003-12-04 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
0026148579 | 2006-07-11 | Plug / Plug Back | No Violations | The wire line tool (tubing cutter) got hung inside the tubing and lost at approximately 1120 feet. The job was postponed. |
0034888376 | 2006-06-30 | Plug / Plug Back | No Violations | Pumped cement plug through the tubing into the injection zone. |
0097918536 | 2007-02-16 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0160658252 | 2016-10-27 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted on the tank. The containment dike is free of fluids. |
0162411494 | 2006-09-12 | Surface Facility Construction | No Violations | Old tanks and concrete dike have been removed. Approximately half the site was graded. Upper concrete pad was constructed with a new 210 bbl tank in place. Work on hold due to rain. |
0184754198 | 2006-08-03 | Salt Water Injection Well | No Violations | Witnessed a cement squeeze job on the 4 1/2 inch casing. Wiper plug sent to 2630 feet. |
0208058352 | 2005-07-28 | Salt Water Injection Well | No Violations | Oil and water inside dike. Notified the operator that the dike needed cleaned-up. |
0216142501 | 2005-01-13 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0264255952 | 2006-06-14 | Salt Water Injection Well | No Violations | No action has been taken to remedy the violations. |
0266102610 | 2004-08-17 | Salt Water Injection Well | Violations Noted | Oil pooling inside dike. Notified well tender. |
0309365208 | 2013-10-28 | Salt Water Injection Well | No Violations | Inspected containment dike, tanks, annulus pressure, injection pressure and injection pump. Dike is free of water. Identification is on tank. |
0314250351 | 2011-03-08 | Salt Water Injection Well | No Violations | Dike free of fresh water. |
0348166438 | 2007-07-17 | Salt Water Injection Well | No Violations | No violations were found at the time of inspection. |
0403589900 | 2013-07-17 | Salt Water Injection Well | No Violations | No violations. |
0405495453 | 2010-11-24 | Salt Water Injection Well | No Violations | Dike is free of water. New injection line connections are not leaking. |
0434129276 | 2006-08-30 | Surface Facility Construction | No Violations | Work on the surface facility progressing. |
0447080295 | 2016-12-20 | Surface Facility Construction | No Violations | Currently installing concrete forms for a new unloading pad. (Approval for the unloading bad was granted June,24, 2015) |
0447604848 | 2006-10-17 | Salt Water Injection Well | No Violations | No violations. Accompanied by Jon Scott. |
0458835377 | 2004-07-15 | Salt Water Injection Well | No Violations | NOV FOLLOW-UP The well is in noncompliance. The valve on the annulus needs replaced. Spoke with the well tender regarding the required remedy. |
0468537078 | 2014-02-20 | Salt Water Injection Well | No Violations | Follow up to 935681809. Dike repairs not made yet. |
0479986209 | 2006-06-27 | Salt Water Injection Well | No Violations | The well was in compliance. |
0482382786 | 2016-03-02 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016. REPORTS RECEIVED 3/18/2016. |
0492626496 | 2006-08-11 | Salt Water Injection Well | No Violations | Preformed a mechanical integrity test on the well. Started the test with an annular pressure of 836 psi.. The well passed with a 0.6% loss in pressure, over a 15 minute period. |
0532289267 | 2006-07-26 | Plug / Plug Back | No Violations | Completed the plug-back of the well. |
0546468863 | 2006-09-07 | Surface Facility Construction | No Violations | Work on the surface facility progressing. |
0560004650 | 2008-09-11 | Salt Water Injection Well | No Violations | No violations were found at the time of inspection. |
0584938746 | 2010-03-18 | Salt Water Injection Well | No Violations | Good identification. Dike is clean with no water in it. |
0586316528 | 2008-04-21 | Salt Water Injection Well | No Violations | There were no violations at the time at the time of inspection. |
0606662405 | 2007-10-22 | Salt Water Injection Well | No Violations | There were no violations. |
0612619482 | 2006-07-18 | Plug / Plug Back | No Violations | Washing out the tubing (just below 900 feet) in order to retrieve the wire line tool at 1120 feet. |
0644379105 | 2015-10-23 | Salt Water Injection Well | No Violations | No noted violations. |
0734557798 | 2013-06-06 | Salt Water Injection Well | No Violations | Follow up to -1618094538. The cracks in the dikes have been sealed. |
0753672285 | 2006-07-31 | Salt Water Injection Well | No Violations | |
0760721356 | 2008-02-25 | Salt Water Injection Well | Violations Noted | An inspection found that there was no fittings to monitor the annulus pressure. All other conditions were acceptable. |
0766873628 | 2016-07-18 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted on the tank. Containment dike is free of fluids. |
0780271050 | 2012-06-25 | Salt Water Injection Well | No Violations | No violations. |
0869167061 | 2019-03-07 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
0876056634 | 2015-09-21 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Construction on the unloading pad has not commenced. |
0895875091 | 2006-03-29 | Salt Water Injection Well | Violations Noted | Oil and water pooling inside the dike. The threads, inside the 1/4 inch needle valve on the backside, were corroded and no longer operational. |
0905121282 | 2004-10-08 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0908607114 | 2009-08-18 | Salt Water Injection Well | No Violations | Good identification. No violations at the time of inspection. |
0915878355 | 2008-11-06 | Salt Water Injection Well | No Violations | Notified the well tender that the gauge on the annulus was started to round-off. |
0935681809 | 2013-11-26 | Salt Water Injection Well | Violations Noted | Flow meter at well read 2242 Barrels. A small crack was noticed in the dike and water was flowing into dike. Dike shall be repaired or replaced in order to be water tight. Spoke with field manager on site and discussed repairs. |
0954425920 | 2006-07-14 | Salt Water Injection Well | No Violations | No one onsite. |
0966095518 | 2005-05-06 | Salt Water Injection Well | Violations Noted | Measured pressures while pump was off. The well was pumping at 830 psi.. |
0985386220 | 2003-07-11 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 1058282884 An inspection of the well site revealed the following:
A storage tank was leaking a stream of brine. The dike was half full of brine. There were several cracks in the dike walls. The two 1/4 inch valves on the well were inoperative. R |
0994581678 | 2011-10-25 | Salt Water Injection Well | No Violations | No violations observed during inspection. |
1009030321 | 2009-11-24 | Salt Water Injection Well | No Violations | Has identification. No violations observed during inspection. |
1013875276 | 2011-08-24 | Salt Water Injection Well | No Violations | Water truck on site. |
1015311589 | 2006-08-10 | Salt Water Injection Well | No Violations | No one on site. |
1019772435 | 2006-05-17 | Salt Water Injection Well | No Violations | The needle valve was replaced. However, the 2 inch valve on the annulus will not open. The dike needs further cleanup. |
1031969427 | 2004-02-05 | Salt Water Injection Well | No Violations | Well pressures were measured just after pump had shut off. No violations at the time of inspection. |
1046566042 | 2017-02-23 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure, and annulus pressure. Identification is posted. The containment dike is free of fluids. The new unloading pad is formed up for concrete. I asked Jonathan Reese when they plan to pour the concrete for the unloading pad. He told me that it has not been scheduled. |
1051658233 | 2007-06-04 | Salt Water Injection Well | No Violations | No violations were found at the time. |
1058282884 | 2003-07-11 | Production Wells | Violations Noted | An inspection of the well site revealed the following:
A storage tank was leaking a stream of brine. The dike was half full of brine. There were several cracks in the dike walls. The two 1/4 inch valves on the well were inoperative. Repair or replace leaking storage tank. Remove brine and oil from inside the dike. Seal cracks in order to make the dike watertight. Repair or replace the valves to allow monitoring. |
1087055346 | 2018-10-15 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike sump pit is full of fluid with an oil coating. I contacted Butch Barton to see if there was an issue with the sump pump. |
1117869689 | 2019-05-23 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. Jonathan Reese was notified that the concrete dike has some cracks that need to be patched. |
1132155442 | 2005-11-15 | Salt Water Injection Well | Violations Noted | Unable to screw gauge into the needle valve on annulus. |
1134615602 | 2011-10-25 | Salt Water Injection Well | No Violations | Accompanied J. Scott on SWIW inspection. No violations, loading pad may need have cement and drain installed. |
1154680320 | 2017-04-06 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. The new unloading pad is formed up for concrete. The concrete for the unloading pad has not been scheduled. |
1159462003 | 2006-09-28 | Surface Facility Construction | No Violations | Plumbing in the flow lines. |
1166557908 | 2006-12-18 | Salt Water Injection Well | No Violations | The pressures were measured, while the pump was operating. |
1186407148 | 2007-04-12 | Salt Water Injection Well | No Violations | No violations were found. |
1211154843 | 2017-08-30 | Salt Water Injection Well | No Violations | My inspection today revealed the salt water injection well had 265 psi on the annulus and 225 psi on the injection tubing. Legible identification was posted. |
1223813687 | 2004-07-20 | Salt Water Injection Well | No Violations | NOV FOLLOW-UP The well has a new needle valve, on the annulus. The dike will require some clean-up work. |
1233436912 | 2017-05-15 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2016, despite a letter that was sent April 28, 2017 with a deadline of May 12, 2017 to submit the reports requested. please submit the requested Forms to the Division by 5/26/2017. REPORTS RECEIVED 7/3/2017 |
1244932222 | 2016-02-08 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted on the tank. |
1248148422 | 2016-04-14 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure, and annulus pressure. Identification posted on the tank, the containment dike is free of fluids. |
1253271848 | 2003-03-05 | Salt Water Injection Well | No Violations | No violations, unable to check pressures need small wrench. |
1260645893 | 2009-03-11 | Salt Water Injection Well | No Violations | The two inch annulus valve froze and broke. Therefore, the annulus pressure was not gauged. |
1274758837 | 2014-10-07 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2010, 2011, 2012 and 2013. The Disposal Fee Report for the 3rd and 4th quarter of 2013 also needs to be reported. |
1279819432 | 2010-07-14 | Salt Water Injection Well | Violations Noted | Pump is dripping. 2 steel line is leaking between 90 and hammer union. I have talked to Jonathan Reese and it will be repaired next week. Parts have to be ordered. All brine drips are being contained with in the dike. |
1305032450 | 2015-03-12 | Salt Water Injection Well | No Violations | No noted violations. Pump running during inspection. |
1313315948 | 2010-09-27 | Salt Water Injection Well | Violations Noted | New 2 pipe from the union to flex line has multiple leaks. One major leak is on the welded 90 ELL. The Other major leak has a rag (held in place with black tape) covering the leak. The leaks must be fixed. All materials used on the line must be able to with stand the max injection pressures of 1245 psi. Please provide documentation on the flex stainless steel line as to pressure rating. |
1329981190 | 2015-06-02 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Verified quantity of tanks for UIC section. |
138173182 | 2020-3-5 0:00:0 | SW | No Violations | |
1390711440 | 2014-11-24 | Salt Water Injection Well | Violations Noted | Two large areas of contaminated soils were noted outside the containment dike at the facility. Company was not offloading brine over top concrete pad. The first area was roughly 35x15 feet and was field tested and found to have more than 6864 ppm Cl- content. The second area was roughly 20x20 feet and was field tested and found to have 3102 ppm Cl- content. All contaminated soils shall be removed and disposed of properly, affected areas shall have topsoil restored and seeded and mulched in order to establish vegetative cover. If company is to continue offloading brine at facility, trucks shall be offloaded in the approved area. I spoke with Tom Schoonover of JD Drilling about remediating the violations. |
1391522268 | 2014-02-04 | Salt Water Injection Well | No Violations | Follow up to 935681809. Unable to verify dike repairs due to frozen conditions. No noted violations, pump running at time of inspection. |
1406232116 | 2014-07-24 | Salt Water Injection Well | No Violations | No noted violations. |
1440344665 | 2009-06-08 | Salt Water Injection Well | No Violations | There were no violations at the time. |
144053350 | 2019-10-8 0:00: | SW | No Violations | 1.50 |
1484468400 | 2004-04-08 | Salt Water Injection Well | No Violations | Bad valve on annulus. |
1488255564 | 2008-06-02 | Salt Water Injection Well | No Violations | There were no violations found at the time of inspection. |
1496623811 | 2014-05-20 | Salt Water Injection Well | No Violations | Follow up to 935681809. Dike patched. No noted violations. Flow meter read 7256 Barrels at 15 gallons/minutes. |
1516547420 | 2014-12-16 | Salt Water Injection Well | No Violations | Follow up to 1390711440. The areas of contamination remain on the outside of the dike. |
1525438829 | 2018-05-04 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the 2017 Salt Water Injection Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. Form 204 received 6/21/2018. |
1529149513 | 2014-12-18 | Salt Water Injection Well | No Violations | Follow up to 1390711440. Contamination near dike has been removed and stone has been laid down to provide an area to park company service vehicles. The salt water load line has been removed. The area in the field has had the soil worked and has been treated with lime. |
1555341606 | 2019-04-03 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted on tank. The containment dike is free of fluids although there is oil residue in the low portion of the dike near the sump pit. Jonathan Reese was contacted about the oil residue. |
1574195057 | 2013-11-26 | Salt Water Injection Well | No Violations | Accompanied Inspector Josh Garland on inspection. He checked pressures on the well. Water was flowing into tank battery containment via a crack in the concrete. The pumper stopped by and we talked with him about repair options. |
1618094538 | 2013-01-18 | Salt Water Injection Well | Violations Noted | Pump running during inspection. The upper dike with the 210 Barrel steel tank is developing small cracks in the bottom. The dike shall be repaired or replaced so that it is water tight. |
1618102059 | 2019-04-29 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019. |
1621905531 | 2010-09-30 | Salt Water Injection Well | No Violations | Replaced leaking fittings and pipe with yellow flex pipe. Writing on side of yellow flex pipe is: 4805 wire air 600 psi wp 40 bar. No leaks observed. |
162411494 | 2006-9-12 0:00: | SC | No Violations | |
1649795380 | 2012-08-22 | Salt Water Injection Well | No Violations | No violations. |
1680881677 | 2005-06-16 | Salt Water Injection Well | No Violations | The owners representative increased the pressure on the annulus to 1220 psi. The pressures on both sides were monitored for 30 minutes. As the tubing pressure dropped, the annular pressure increased 25 psi. Overall, the well demonstrated mechanical integrity.
(Injection: start 758 psi / stop 738 psi Annulus: start 1220 psi / stop 1245 psi) |
1681259005 | 2006-10-04 | Surface Facility Construction | No Violations | Surface facility construction was complete. |
1685942370 | 2008-12-03 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1689183921 | 2007-09-10 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. Pump was operating. |
1704791323 | 2014-10-27 | Salt Water Injection Well | No Violations | Compliance Notice satisfied. All reports requested received. |
1717519550 | 2018-03-14 | Salt Water Injection Well | No Violations | My inspection revealed the salt water injection well had 350 psi on the tubing and 280 psi on the annulus. The dike was free of fluids. Legible identification was posted. |
1723700535 | 2013-12-19 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure, and annulus pressure. Identification is posted on the 1st tank. Dike is free of water. |
1743473294 | 2019-01-08 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
1745430411 | 2018-02-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. Reports received 5/11/2018 |
1752871480 | 2006-09-21 | Surface Facility Construction | No Violations | Concrete dike completed. In the process of setting the tanks (a 210 bbl knockout, two 210 bbl brine tanks and one 100 bbl oil tank.) |
1764112445 | 2017-02-28 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarters of 2016. Please submit the appropriate reports by March 14, 2017. Fees and Fee reports received 7/3/2017 |
1783769261 | 2016-03-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. Form 204 received 7/13/2017 |
1802200386 | 2016-12-20 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
184754198 | 2006-8-3 0:00:0 | SW | No Violations | |
1847702381 | 2011-08-09 | Preliminary Restoration | No Violations | Vegetation reestablished, no erosion, no drilling equipment, good ID. PR passed. |
1902001620 | 2013-04-08 | Salt Water Injection Well | No Violations | Inspected containment dike, injection pressure and annulus pressure. Good identification on tank. Dike is free of water. |
1942848369 | 2015-04-23 | Salt Water Injection Well | No Violations | No noted violations at time of inspection. |
1969404457 | 2018-09-18 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
1974093826 | 2015-10-06 | Surface Facility Construction | No Violations | Inspected the surface facility with UIC Section Geologist. Measured containment dike and documented tank connections. |
2009016423 | 2018-08-13 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
2018145642 | 2006-07-27 | Salt Water Injection Well | No Violations | Tested the well (bottom plug) with 1810 psi. on the 4 1/2 inch casing. The well passed, losing 5 psi. total over a 15 minutes period. |
2025019888 | 2004-05-03 | Salt Water Injection Well | Violations Noted | Unable to measure the pressure on the annulus, because the valve is corroded shut. |
2026233351 | 2020-4-15 0:00: | SW | No Violations | 1.00 |
208058352 | 2005-7-28 0:00: | SW | No Violations | |
2083295145 | 2006-10-18 | Salt Water Injection Well | No Violations | No violations at the time. Spoke with Spence Carpenter, regarding the rainwater run-off. |
2142887619 | 2018-06-06 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
26148579 | 2006-7-11 0:00: | PB | No Violations | |
264255952 | 2006-6-14 0:00: | SW | No Violations | |
266102610 | 2004-8-17 0:00: | SW | No Violations | |
348166438 | 2007-7-17 0:00: | SW | No Violations | |
34888376 | 2006-6-30 0:00: | PB | No Violations | |
405495453 | 2010-11-24 0:00 | SW | No Violations | |
434129276 | 2006-8-30 0:00: | SC | No Violations | |
447080295 | 2016-12-20 0:00 | SC | No Violations | 0.50 |
447604848 | 2006-10-17 0:00 | SW | No Violations | |
482382786 | 2016-3-2 0:00:0 | SW | No Violations | |
504141417 | 2020-5-6 0:00:0 | SW | No Violations | |
532289267 | 2006-7-26 0:00: | PB | No Violations | |
546468863 | 2006-9-7 0:00:0 | SC | No Violations | |
560004650 | 2008-9-11 0:00: | SW | No Violations | |
584938746 | 2010-3-18 0:00: | SW | No Violations | |
586316528 | 2008-4-21 0:00: | SW | No Violations | |
606662405 | 2007-10-22 0:00 | SW | No Violations | |
612619482 | 2006-7-18 0:00: | PB | No Violations | |
644379105 | 2015-10-23 0:00 | SW | No Violations | 0.70 |
734557798 | 2013-6-6 0:00:0 | SW | No Violations | 0.70 |
780271050 | 2012-6-25 0:00: | SW | No Violations | 0.30 |
7890950 | 2003-12-4 0:00: | SW | No Violations | |
790260950 | 2020-1-2 0:00:0 | SW | No Violations | 2.00 |
876056634 | 2015-9-21 0:00: | SW | No Violations | 1.50 |
888527465 | 2020-7-30 0:00: | SW | No Violations | 2.20 |
905121282 | 2004-10-8 0:00: | SW | No Violations | |
908607114 | 2009-8-18 0:00: | SW | No Violations | |
915878355 | 2008-11-6 0:00: | SW | No Violations | |
935681809 | 2013-11-26 0:00 | SW | No Violations | 0.50 |
9544259201 | 2006-07-14 | Plug / Plug Back | No Violations | No one onsite. |
994581678 | 2011-10-25 0:00 | SW | No Violations | |
UIC119 | 1987-3-9 0:00:0 | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0266102610 | US-OH-122748 | 2004-08-19 | Pollution/Contamination | |
0760721356 | US-OH-128651 | 2008-03-11 | Failure to monitor annulus pressure | |
0895875091 | US-OH-130224 | 2006-04-16 | Pollution/Contamination | |
0895875091 | US-OH-130225 | 2006-04-16 | Violation of injection tubing/fitting requirements | |
0935681809 | US-OH-130710 | 2014-09-29 | Pits not liquid tight/Improper construction or use | |
0966095518 | US-OH-131069 | 2005-05-11 | Pollution/Contamination | |
0966095518 | US-OH-131070 | 2005-05-11 | Violation of injection tubing/fitting requirements | |
0966095518 | US-OH-131071 | 2005-05-16 | Failure to perform Mechanical Integrity Test | |
0985386220 | US-OH-131321 | 2003-07-15 | No SPCC dike/or failure to keep dike free of water or oil | |
0985386220 | US-OH-131322 | 2003-07-15 | Dike or pit not able to prevent escape of brine or other wastes | |
0985386220 | US-OH-131323 | 2003-07-15 | Violation of injection tubing/fitting requirements | |
0985386220 | US-OH-131324 | 2003-07-15 | Contamination at surface facility (permit after 6-1-82) | |
0985386220 | US-OH-131325 | 2003-07-15 | Tanks not liquid tight/Improper burial | |
1058282884 | US-OH-101101 | 2003-07-15 | No SPCC dike/or failure to keep dike free of water or oil | |
1058282884 | US-OH-101102 | 2003-07-15 | Dike or pit not able to prevent escape of brine or other wastes | |
1058282884 | US-OH-101103 | 2003-07-15 | Violation of injection tubing/fitting requirements | |
1058282884 | US-OH-101104 | 2003-07-15 | Contamination at surface facility (permit after 6-1-82) | |
1058282884 | US-OH-101105 | 2003-07-15 | Tanks not liquid tight/Improper burial | |
1132155442 | US-OH-103361 | 2005-11-16 | Violation of injection tubing/fitting requirements | |
1233436912 | US-OH-106260 | 2017-07-13 | 9-3-04B | Failure to file salt water injection annual report |
1274758837 | US-OH-107633 | 2014-10-31 | Failure to file salt water injection annual report | |
1279819432 | US-OH-107767 | 2010-07-22 | Mechanical failure/contamination | |
1313315948 | US-OH-108912 | 2010-09-28 | Mechanical failure/contamination | |
1390711440 | US-OH-111558 | 2015-02-03 | Contamination at surface facility (permit after 6-1-82) | |
1525438829 | US-OH-114359 | 2018-08-03 | Failure to file salt water injection annual report | |
1618094538 | US-OH-115897 | 2013-06-06 | Pits not liquid tight/Improper construction or use | |
1618102059 | US-OH-115898 | 2019-05-09 | Failure to file salt water injection annual report | |
1745430411 | US-OH-117344 | 2018-08-03 | NONE | Failure to report disposal fees |
1783769261 | US-OH-117765 | 2017-07-13 | 9-3-04B | Failure to file salt water injection annual report |
2025019888 | US-OH-120593 | 2004-05-06 | Violation of injection tubing/fitting requirements | |
2025019888 | US-OH-120594 | 2004-05-06 | Failure to monitor annulus pressure |
For data sources see[5]