Well Details

Well ID: 34-103-24094
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Sharon Township
Operator Name: RANDELL OIL CO
Well Pad ID:
Farm/Lease Name: BURDETT KEITH B& ELLEN M
License Status: Producing
License Date: 1985-05-13
Spud Date: 1985-05-22
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1985-05-27
Well Total Depth: 3709.00 ft
Configuration: Vertical
Latitude: 41.090000
Longitude: -81.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1985-05-13 Issued Date 5/13/85 Expired Date 5/13/86 Acres 0060590 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03709 Proposed Drill Depth 03709
Original Spud 1985-05-22 ACRES=58.1404
Completed 1985-05-27 ACRES=58.1404
Reached Total Depth 1985-05-27 ACRES=58.1404
CO 1985-06-21 289 ALL STATES OIL & PROD GeoDate 5/13/85
Completion Report Received 1985-06-24 ACRES=58.1404
Construction Permit Expires 1986-05-13 ACRES=58.1404
Change of Owner 1999-03-30 Operator changed from 289, ALL STATES OIL & PROD to 2409, RANDELL OIL CO
Record Last Modified 2017-02-15 ACRES=58.1404

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3506 3610 2
3506 3610 2
3506 3610 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 30000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1998 ALL STATES OIL & PRODUCING CO 0.00 30.00 0
1999 RANDELL OIL CO 0.00 0.00 0
2000 RANDELL OIL CO 0.00 0.00 0
2001 RANDELL OIL CO 0.00 0.00 0
2002 RANDELL OIL CO 0.00 107.00 365
2003 RANDELL OIL CO 0.00 80.00 365
2004 RANDELL OIL CO 0.00 70.00 365
2005 RANDELL OIL CO 0.00 38.00 365
2006 RANDELL OIL CO 0.00 33.00 365
2007 RANDELL OIL CO 0.00 32.00 365
2008 RANDELL OIL CO 0.00 0.00 0
2009 RANDELL OIL CO 0.00 33.00 365
2011 RANDELL OIL CO 0.00 35.00 0
2012 RANDELL OIL CO 0.00 0.00 0
2013 RANDELL OIL CO 0.00 0.00 0
2014 RANDELL OIL CO 0.00 28.00 365
2015 RANDELL OIL CO 0.00 0.00 0
2016 RANDELL OIL CO 0.00 0.00 0
2017 RANDELL OIL CO 0.00 0.00 0
2018 RANDELL OIL CO 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1998 ALL STATES OIL & PRODUCING CO Brine 0
1999 RANDELL OIL CO Brine 0 0
2000 RANDELL OIL CO Brine 0 0
2001 RANDELL OIL CO Brine 0 0
2002 RANDELL OIL CO Brine 23 365
2003 RANDELL OIL CO Brine 0 365
2004 RANDELL OIL CO Brine 0 365
2005 RANDELL OIL CO Brine 40 365
2006 RANDELL OIL CO Brine 0 365
2007 RANDELL OIL CO Brine 40 365
2008 RANDELL OIL CO Brine 0 0
2009 RANDELL OIL CO Brine 0 365
2011 RANDELL OIL CO Brine 0
2012 RANDELL OIL CO Brine 0 0
2013 RANDELL OIL CO Brine 0 0
2014 RANDELL OIL CO Brine 8 365
2015 RANDELL OIL CO Brine 0 0
2016 RANDELL OIL CO Brine 0 0
2017 RANDELL OIL CO Brine 0 0
2018 RANDELL OIL CO Brine 22 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
000PL11464 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0957973144 2014-06-26 Production Wells No Violations Inspected production well on 06/26/2014. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank (buried and serving as an underground brine vault), and 1-vertical separator located within an earthen dike. A very small leak was noted from the plug at the bottom of the 100 bbl tank; the leak is contained to the area immediately underneath the plug. The tank battery is used by multiple wells (2); identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. A stuffing box leak affecting the area immediately around the wellhead was noted at the time of the inspection. Well identification is posted at the wellhead as required. Randell Oil was notified of these issues and will address them as soon as possible. No other problems were noted at the time of the inspection.
1139943893 2006-02-14 Production Wells No Violations Well in production. Equipped with pump jack,rods and tubing. 1-100 barrel tank and 1-100 barrel tank underground not being used. Sun, 35 degrees.
1358970899 2013-01-23 Production Wells No Violations I inspected this well and found one pump jack with electric motor on the wellhead. The pressure on the tubing was 60 psi. and I could not determine the pressure on the casing due to the gauge being broken. No leaks were detected on the wellhead or on the piping around the wellhead. The area around the pump jack and wellhead was nicely maintained. The tank battery contained one 100 bbl. steel oil storage tank, one in ground steel brine storage tank, one vertical oil and gas separator unit and one drip assembly. The proper identification sign was posted on the steel tank and no leaks were detected on the steel tank or piping within the tank battery. The area within and around the tank battery was well maintained. The dike was eroded and insufficient in height to contain any substantial amount of fluid should there be a spill. The entire south side of the dike was eroded away and non existent. It was determined that this tank battery also handles the production for the Burdett #2 well. I contacted John Davis, production mgr. for Randell Oil (330)-621-1483, about the eroded dike and advised him that he will need to repair it within the next sixty days.
2006448222 2015-09-21 Production Wells No Violations Inspected production well on 09/21/2015. The tank battery consists of 1-100 bbl steel tank, 1-partially-buried 50 bbl steel tank (used as an underground brine vault), and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (2); no well identification is posted at the tank battery. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead, but it does not reflect the current operator and needs updated. John Davis with Randell Oil was notified of this issue and will address it promptly. No other problems were noted at the time of the inspection.
957973144 2014-6-26 0:00: PW No Violations
PL11464 PL No Violations

For data sources see[9]