X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-23057

Well Details

Well ID: 34-103-23057
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Granger Township
Operator Name: VANGUARD OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: MCDONALD AJ
License Status: Producing
License Date: 1982-11-01
Spud Date: 1982-11-04
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1982-11-08
Well Total Depth: 3662.00 ft
Configuration: Vertical
Latitude: 41.180000
Longitude: -81.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1982-04-09 182 BELDEN & BLAKE CO GeoDate 4/9/82
Oil and Gas 1982-04-09 Issued Date 4/9/82 Expired Date 4/9/82 Acres 0024147 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1982-11-01 182 BELDEN & BLAKE CO GeoDate 11/1/82
Oil and Gas 1982-11-01 Issued Date 11/1/82 Expired Date 4/30/83 Acres 0024147 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03662 Proposed Drill Depth 03662
Original Spud 1982-11-04 RI 11-6-82
Completed 1982-11-08 RI 11-6-82
Reached Total Depth 1982-11-08 RI 11-6-82
Completion Report Received 1983-01-25 RI 11-6-82
Construction Permit Expires 1983-04-30 RI 11-6-82
Change of Owner 2001-04-05 Operator changed from 457, ALSID OIL & GAS to 6970, VANGUARD OIL & GAS LLC
Record Last Modified 2017-02-15 RI 11-6-82

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3497 3536 13
3497 3536 13
3497 3536 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 74960 Gal 50000 FRAC: 75MG H2O, 50M SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION 5852.00 834.00 0
1985 BELDEN & BLAKE CORPORATION 3999.00 278.00 0
1986 BELDEN & BLAKE CORPORATION 2617.00 125.00 365
1987 BELDEN & BLAKE CORPORATION 1078.00 87.00 365
1988 BELDEN & BLAKE CORPORATION 2093.00 280.00 150
1990 BELDEN & BLAKE CORPORATION 2402.00 386.00 355
1991 BELDEN & BLAKE CORPORATION 1842.00 256.00 365
1992 BELDEN & BLAKE CORPORATION 1652.00 139.00 366
1993 BELDEN & BLAKE CORPORATION 1058.00 155.00 358
1994 BELDEN & BLAKE CORPORATION 816.00 137.00 81
1995 BELDEN & BLAKE CORPORATION 508.00 0.00 365
1996 BELDEN & BLAKE CORPORATION 257.00 0.00 366
1997 BELDEN & BLAKE CORPORATION 0.00 102.00 120
1998 ALSID OIL & GAS 820.00 162.00 365
1999 ALSID OIL & GAS 526.00 112.00 365
2000 VANGUARD OIL & GAS LLC 122.00 113.00 365
2001 VANGUARD OIL & GAS LLC 651.00 97.00 365
2002 VANGUARD OIL & GAS LLC 61.00 0.00 365
2003 VANGUARD OIL & GAS LLC 211.00 0.00 365
2005 VANGUARD OIL & GAS LLC 0.00 0.00 0
2006 VANGUARD OIL & GAS LLC 0.00 0.00 0
2007 VANGUARD OIL & GAS LLC 0.00 0.00 0
2009 VANGUARD OIL & GAS LLC 0.00 0.00 365
2010 VANGUARD OIL & GAS LLC 0.00 0.00 365
2011 VANGUARD OIL & GAS LLC 0.00 0.00 0
2012 VANGUARD OIL & GAS LLC 0.00 0.00 366
2013 VANGUARD OIL & GAS LLC 0.00 0.00 365
2014 VANGUARD OIL & GAS LLC 0.00 0.00 365
2015 VANGUARD OIL & GAS LLC 0.00 0.00 365
2016 VANGUARD OIL & GAS LLC 0.00 0.00 365
2017 VANGUARD OIL & GAS LLC 0.00 0.00 365
2018 VANGUARD OIL & GAS LLC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION Brine 0 0
1985 BELDEN & BLAKE CORPORATION Brine 143 0
1986 BELDEN & BLAKE CORPORATION Brine 3 365
1987 BELDEN & BLAKE CORPORATION Brine 11 365
1988 BELDEN & BLAKE CORPORATION Brine 53 150
1990 BELDEN & BLAKE CORPORATION Brine 82 355
1991 BELDEN & BLAKE CORPORATION Brine 42 365
1992 BELDEN & BLAKE CORPORATION Brine 59 366
1993 BELDEN & BLAKE CORPORATION Brine 4 358
1994 BELDEN & BLAKE CORPORATION Brine 53 81
1995 BELDEN & BLAKE CORPORATION Brine 0 365
1996 BELDEN & BLAKE CORPORATION Brine 0 366
1997 BELDEN & BLAKE CORPORATION Brine 14 120
1998 ALSID OIL & GAS Brine 0 365
1999 ALSID OIL & GAS Brine 0 365
2000 VANGUARD OIL & GAS LLC Brine 28 365
2001 VANGUARD OIL & GAS LLC Brine 0 365
2002 VANGUARD OIL & GAS LLC Brine 0 365
2003 VANGUARD OIL & GAS LLC Brine 0 365
2005 VANGUARD OIL & GAS LLC Brine 0 0
2006 VANGUARD OIL & GAS LLC Brine 0 0
2007 VANGUARD OIL & GAS LLC Brine 0 0
2009 VANGUARD OIL & GAS LLC Brine 0 365
2010 VANGUARD OIL & GAS LLC Brine 0 365
2011 VANGUARD OIL & GAS LLC Brine 0
2012 VANGUARD OIL & GAS LLC Brine 0 366
2013 VANGUARD OIL & GAS LLC Brine 0 365
2014 VANGUARD OIL & GAS LLC Brine 0 365
2015 VANGUARD OIL & GAS LLC Brine 0 365
2016 VANGUARD OIL & GAS LLC Brine 0 365
2017 VANGUARD OIL & GAS LLC Brine 0 365
2018 VANGUARD OIL & GAS LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1362458425 2015-6-22 0:00: PW No Violations
-1855630918 2014-10-1 0:00: PW No Violations
-70255482 2013-5-22 0:00: PW No Violations 0.50
000PL11943 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0070255482 2013-05-22 Production Wells No Violations The pump jack is overgrown with brush and small trees. The tanks are located at the lease road entry on the east side of Allard Rd. The oil tank has a leak from a fitting on the rear side of the tank. The ground around the tank was saturated with fluid; fluid was contained within the dike area. There is also a concrete brine tank buried in the dike which was full of debris. The operator advised that they had no pipeline access for gas, one landowner is using house gas from the well and the well has not been pumped in a while. The operator stated they would check the tank, correct the leak issue and possibly apply for a plug permit on the well.
1362458425 2015-06-22 Production Wells No Violations Inspected production well on 06/22/2015 to follow-up on a previously-issued compliance notice. The tank battery consists of 1-210 bbl steel tank, 1-vertical separator, and 1-underground brine vault located within an overgrown earthen dike. Well identification is posted, but it is almost too faded to read. The well is equipped with a pump jack with a hitmiss motor. The area around the well is very overgrown. Spoke to Russell Miller with Vanguard. He was unaware there was a compliance notice open on the well. He will speak to office staff to determine their plan forward and keep me posted. Will continue to monitor the situation.
1855630918 2014-10-01 Production Wells Violations Noted Inspected production well on 10/01/2014. The tank battery consists of 1-210 bbl steel tank, 1-vertical separator and an underground brine vault located within an earthen dike. A small oil leak was noted from the connections at the back of the tank, affecting an area approximately 3 x 5 within the earthen dike, that will need to be cleaned up. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with a gas-powered motor, however the motor does not appear to be hooked-up. Research into the production history of the well showed that it has not produced since 2003, therefore the well must be plugged.
PL11943 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1855630918 US-OH-118565 2014-11-12 Well shall be plugged

For data sources see[9]

References