X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-21543

Well Details

Well ID: 34-103-21543
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Sharon Township
Operator Name: KING DRILLING CO
Well Pad ID:
Farm/Lease Name: SULLIVAN TW
License Status: Producing
License Date: 1965-04-23
Spud Date: 1965-04-22
Spud Drilling Contractor:
Final Drill Date: 1965-05-31
Well Total Depth: 3551.00 ft
Configuration: Vertical
Latitude: 41.090000
Longitude: -81.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1965-04-22 ?=10 ACRE UNIT
Completed 1965-05-31 ?=10 ACRE UNIT
Reached Total Depth 1965-05-31 ?=10 ACRE UNIT
Record Last Modified 2013-10-03 ?=10 ACRE UNIT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3466 3482 32
3466 3482 32
3466 3482 32

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 900 Bbl 29000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 KING DRILLING CO 17.00 0.00 0
1985 KING DRILLING CO 5.00 0.00 0
1986 KING DRILLING CO 0.00 62.00 365
1993 KING DRILLING CO 0.00 36.00 365
1995 KING DRILLING CO 759.00 30.00 365
1996 KING DRILLING CO 717.00 34.00 365
1997 KING DRILLING CO 525.00 15.00 365
1998 KING DRILLING CO 517.00 15.00 365
1999 KING DRILLING CO 702.00 45.00 365
2000 KING DRILLING CO 625.00 44.00 365
2001 KING DRILLING CO 471.00 29.00 365
2002 KING DRILLING CO 509.00 30.00 365
2003 KING DRILLING CO 634.00 43.00 365
2004 KING DRILLING CO 606.00 39.00 365
2005 KING DRILLING CO 553.00 39.00 365
2006 KING DRILLING CO 509.00 20.00 365
2007 KING DRILLING CO 475.00 15.00 365
2008 KING DRILLING CO 408.00 33.00 365
2009 KING DRILLING CO 282.00 26.00 365
2010 KING DRILLING CO 252.00 30.00 365
2011 KING DRILLING CO 306.00 31.00 365
2012 KING DRILLING CO 297.00 9.00 366
2013 KING DRILLING CO 234.00 24.00 365
2014 KING DRILLING CO 389.00 23.00 365
2015 KING DRILLING CO 658.00 62.00 365
2016 KING DRILLING CO 577.00 42.00 365
2017 KING DRILLING CO 583.00 43.00 365
2018 KING DRILLING CO 476.00 35.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 KING DRILLING CO Brine 0 0
1985 KING DRILLING CO Brine 0 0
1986 KING DRILLING CO Brine 0 365
1993 KING DRILLING CO Brine 0 365
1995 KING DRILLING CO Brine 0 365
1996 KING DRILLING CO Brine 12 365
1997 KING DRILLING CO Brine 12 365
1998 KING DRILLING CO Brine 0 365
1999 KING DRILLING CO Brine 0 365
2000 KING DRILLING CO Brine 0 365
2001 KING DRILLING CO Brine 0 365
2002 KING DRILLING CO Brine 0 365
2003 KING DRILLING CO Brine 0 365
2004 KING DRILLING CO Brine 0 365
2005 KING DRILLING CO Brine 0 365
2006 KING DRILLING CO Brine 0 365
2007 KING DRILLING CO Brine 0 365
2008 KING DRILLING CO Brine 0 365
2009 KING DRILLING CO Brine 0 365
2010 KING DRILLING CO Brine 0 365
2011 KING DRILLING CO Brine 0 365
2012 KING DRILLING CO Brine 0 366
2013 KING DRILLING CO Brine 0 365
2014 KING DRILLING CO Brine 0 365
2015 KING DRILLING CO Brine 12 365
2016 KING DRILLING CO Brine 0 365
2017 KING DRILLING CO Brine 0 365
2018 KING DRILLING CO Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1487871541 2015-9-21 0:00: PW No Violations
-1954068010 2014-11-20 0:00 PW No Violations
-728781789 2014-9-3 0:00:0 PW No Violations
0611623797 2007-03-12 Production Wells No Violations Met with Andrew King on site. Due to melting snow and rain the oil in wetland is contained and crews are still mopping up oil in water under supervision of OEPA. Discussed construction of new tank battery location at NE corner of park, parking lot. 210 barrel tank removed and new 100 barrel brought in. Cloudy, 45 degrees.
0728781789 2014-09-03 Production Wells No Violations Inspected production well on 09/03/2014. The tank battery, which is shared with multiple wells, was inspected previously. The well is equipped with a pump jack with a gas-powered motor. No well identification is posted at the wellhead as required. Andrew King with King Drilling was notified of this issue and will address it directly. No other problems were noted at the time of the inspection.
1170784101 2007-02-05 Production Wells Violations Noted Called by Andrew King to report an oil spill in a wetland west of Sharon Community Park in Sharon Center. A two inch flow line split outside the dike and approximately two barrels of oil spilled in marsh area. King notified the OEPA and contractors were on site within two hours. I arrived and assessed the contamination. Spill was contained for the evening. 2-6-2007 began removal of trees in oil. Peatsorb was applied to the oil on the water. Trees and contaminated soil will be removed from site after oil is absorbed. Tank battery will be removed and built at a higher elevation. Kurt Kollar of the OEPA arrived to instruct King on the water cleanup issue. ODNR and OEPA will work together to bring this in compliance. Cloudy, -5 degrees.
1171988948 2007-02-20 Production Wells No Violations Well remains shut down due to oil spill clean up. Removing 210 barrel storage tank and built siphon dams to collect oil. 35 degrees12 snow.
1176403000 2007-04-12 Production Wells No Violations Oil contaminated soil has been removed and hauled to Petro Enviromental in Lodi. Seven tons removed. Kurt Kollert of OEPA advised me all water contamination is in compliance. King Drilling has set a new tank battery and dike. Area needs final graded and seeded. Due to weather conditions I gave another extension for final grade.
1179761777 2007-05-21 Production Wells No Violations Case# 07-002. OEPA has released their responsibility on complaint. Tank battery has been replaced and ground is dry. Met with Sharon Township trustee on site to discuss final grading of site. Production oil line is still exposed and needs protected before grading over line. Andrew King and township will notify me when area is reclaimed. Sun, 60 degrees.
1186679610 2007-08-09 Production Wells No Violations NOV in compliance. All oil contamination removed new tank battery instaled and are graded and vegetation growing. Rain, 88 degrees.
1361476132 2013-02-21 Production Wells No Violations I inspected this well and found one pump jack with a natural gas powered motor on the wellhead. The pressure on the tubing was 12 psi. and the pressure on the casing was 20 psi. There was a small steel tank used for injecting well treating chemicals plumbed into the tubing. No leaks were observed on the wellhead or piping around the well. The area around the well was nicely maintained and the wellhead and pump jack unit were enclosed with a three sided tall wooden privacy fence. The wellhead, pump jack and wooden fence were surrounded by tall pine trees concealing the presence of the well. The tank battery contained one 100 bbl. steel oil storage tank and no other production equipment. The proper identification sign was posted on the tank and no leaks were observed on the tank or pipimg within the tank battery. The dike was in good shape and the area within and around the dike was nicely maintained. The tank battery was enclosed on three sides with a tall wooden privacy fence. It was determined that this tank battery also handles production for the Sullivan #1, #2 and #3 wells.
1487871541 2015-09-21 Production Wells No Violations Inspected production well on 09/21/2015. Previous inspections attributed to this well are incorrect; they actually refer to 103-21514, the location of which is incorrect in RBDMS. The tank battery consists of 1-100 bbl steel tank located within an earthen dike and 3/4 of a wooden privacy fence. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with a hitmiss motor located within an unlocked metal fence. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1954068010 2014-11-20 Production Wells No Violations Visited location on 11/20/2014 to ensure that proper well identification had been posted at the wellhead as requested after a previous inspection. The well is equipped with a pump jack with a gas-powered motor located within 3/4 of a wooden fence. Proper well identification is clearly displayed at the wellhead as required. No problems were noted at the time of the inspection.
611623797 2007-3-12 0:00: PW No Violations 1.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1170784101 US-OH-104515 2007-02-06 Inadequate pipeline strength
1170784101 US-OH-104516 2007-02-06 Well insufficiently equipped to prevent escape of oil and gas

For data sources see[9]

References