X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-22538

Well Details

Well ID: 34-099-22538
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Canfield Township
Operator Name: EVERFLOW EASTERN PARTNERS LP
Well Pad ID:
Farm/Lease Name: JOHNSON K UNIT
License Status: Producing
License Date: 1992-07-13
Spud Date: 1992-07-21
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]]
Final Drill Date: 1992-07-31
Well Total Depth: 6237.00 ft
Configuration: Directional
Latitude: 41.010000
Longitude: -80.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1992-07-13 84 EVERFLOW EASTERN PTNS L P GeoDate 7/13/92
Oil and Gas 1992-07-13 Issued Date 7/13/92 Expired Date 7/13/93 Acres 0043610 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 06237 Proposed Drill Depth 06237
Original Spud 1992-07-21 CORRECTED PRODUCTION RECORDS: DELETED 1990-1992; CORRECTED YEARS 1995-1996.
Completed 1992-07-31 CORRECTED PRODUCTION RECORDS: DELETED 1990-1992; CORRECTED YEARS 1995-1996.
Reached Total Depth 1992-07-31 CORRECTED PRODUCTION RECORDS: DELETED 1990-1992; CORRECTED YEARS 1995-1996.
Completion Report Received 1992-08-17 CORRECTED PRODUCTION RECORDS: DELETED 1990-1992; CORRECTED YEARS 1995-1996.
Construction Permit Expires 1993-07-13 CORRECTED PRODUCTION RECORDS: DELETED 1990-1992; CORRECTED YEARS 1995-1996.
Record Last Modified 2017-02-15 CORRECTED PRODUCTION RECORDS: DELETED 1990-1992; CORRECTED YEARS 1995-1996.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-10-01 5956 6011 73
5956 6011 73
5956 6011 73

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 120000 Gal 80000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 DORFMAN PRODUCTION COMPANY 6901.00 586.00 365
1993 EVERFLOW EASTERN PARTNERS LP 33063.00 75.00 344
1994 EVERFLOW EASTERN PARTNERS LP 17864.00 60.00 365
1995 DORFMAN PRODUCTION COMPANY 12512.00 0.00 365
1996 DORFMAN PRODUCTION COMPANY 10689.00 0.00 366
1997 EVERFLOW EASTERN PARTNERS LP 10129.00 48.00 365
1998 EVERFLOW EASTERN PARTNERS LP 10305.00 0.00 365
1999 EVERFLOW EASTERN PARTNERS LP 9407.00 0.00 365
2000 EVERFLOW EASTERN PARTNERS LP 6282.00 0.00 365
2001 EVERFLOW EASTERN PARTNERS LP 6065.00 0.00 365
2002 EVERFLOW EASTERN PARTNERS LP 8026.00 0.00 365
2003 EVERFLOW EASTERN PARTNERS LP 8105.00 0.00 365
2004 EVERFLOW EASTERN PARTNERS LP 6328.00 0.00 365
2005 EVERFLOW EASTERN PARTNERS LP 4851.00 0.00 365
2006 EVERFLOW EASTERN PARTNERS LP 2060.00 0.00 365
2007 EVERFLOW EASTERN PARTNERS LP 1982.00 0.00 365
2008 EVERFLOW EASTERN PARTNERS LP 1854.00 0.00 365
2009 EVERFLOW EASTERN PARTNERS LP 999.00 0.00 365
2010 EVERFLOW EASTERN PARTNERS LP 1585.00 53.00 365
2011 EVERFLOW EASTERN PARTNERS LP 863.00 0.00 197
2012 EVERFLOW EASTERN PARTNERS LP 930.00 0.00 156
2013 EVERFLOW EASTERN PARTNERS LP 1799.00 0.00 185
2014 EVERFLOW EASTERN PARTNERS LP 9097.00 0.00 305
2015 EVERFLOW EASTERN PARTNERS LP 5582.00 20.00 365
2016 EVERFLOW EASTERN PARTNERS LP 5930.00 0.00 365
2017 EVERFLOW EASTERN PARTNERS LP 4001.00 0.00 365
2018 EVERFLOW EASTERN PARTNERS LP 3159.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 DORFMAN PRODUCTION COMPANY Brine 2562 365
1993 EVERFLOW EASTERN PARTNERS LP Brine 240 344
1994 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1995 DORFMAN PRODUCTION COMPANY Brine 1900 365
1996 DORFMAN PRODUCTION COMPANY Brine 1800 366
1997 EVERFLOW EASTERN PARTNERS LP Brine 50 365
1998 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1999 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2000 EVERFLOW EASTERN PARTNERS LP Brine 65 365
2001 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2002 EVERFLOW EASTERN PARTNERS LP Brine 30 365
2003 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2004 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2005 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2006 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2007 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2008 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2009 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2010 EVERFLOW EASTERN PARTNERS LP Brine 35 365
2011 EVERFLOW EASTERN PARTNERS LP Brine 0 197
2012 EVERFLOW EASTERN PARTNERS LP Brine 0 156
2013 EVERFLOW EASTERN PARTNERS LP Brine 0 185
2014 EVERFLOW EASTERN PARTNERS LP Brine 0 305
2015 EVERFLOW EASTERN PARTNERS LP Brine 67 365
2016 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2017 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2018 EVERFLOW EASTERN PARTNERS LP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000014344 Preliminary Restoration No Violations PASSED Y WITNESSED 5/12/93 INSPECTOR BRETT FARNSWORTH DATE 05/1219/93 DATA FROM OLD VAX INFO
14344 PL No Violations
2092312357 2018-05-23 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-2538. ODNR-DOGRM Northeast District Supervisor Stephen Ochs was present during the inspection. Access to the well was on foot due to wet conditions. Correct identification was present at the well head. The 8.625 well head was below grade, with the annulus plumbed into the flow line. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. The horizontal separator was located along the lease road and remained in good repair and contained correct identification. A current 7 day production chart was in the meter box. A stable earthen dike that was contained meteoric water was present around the production tanks. Tanks within the dike consisted of one (1) 100 bbl steel production tank and one (1) 50 bbl steel brine tank. The production tank remained in good repair and contained correct identification. Valves were closed, locked and plugged. The brine tank remained in good repair. The inlet valve was closed. No violations were observed during this inspection

For data sources see[9]

References