X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-20230

Well Details

Well ID: 34-099-20230
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Knox Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: RITCHIE GRETA COMMUNITY
License Status: Producing
License Date: 1966-04-28
Spud Date: 1966-05-26
Spud Drilling Contractor:
Final Drill Date: 1966-06-06
Well Total Depth: 5464.00 ft
Configuration: Vertical
Latitude: 40.900000
Longitude: -80.990000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1801-01-02 240 EAST OHIO GAS CO
Oil and Gas 1802-01-01
Original Spud 1966-05-26 CHG. FTG LOCATION 8-3-85 / GL=1178.5, 1184.5
Completed 1966-06-06 CHG. FTG LOCATION 8-3-85 / GL=1178.5, 1184.5
Reached Total Depth 1966-06-06 CHG. FTG LOCATION 8-3-85 / GL=1178.5, 1184.5
CO 1995-04-20 182 BELDEN & BLAKE CO GeoDate
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
Record Last Modified 2013-10-03 CHG. FTG LOCATION 8-3-85 / GL=1178.5, 1184.5

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5353 5357 8
2006-09-11 5362 5366 8
5353 5357 8
5353 5357 8
2006-09-11 5375 5381 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 150 Gal 0
0 15351 Gal 23000 SEL.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DOMINION EAST OHIO 0.00 424.00 0
1985 DOMINION EAST OHIO 1752.00 928.00 365
1986 DOMINION EAST OHIO 2551.00 929.00 365
1987 DOMINION EAST OHIO 1759.00 457.00 352
1988 DOMINION EAST OHIO 2664.00 707.00 319
1989 DOMINION EAST OHIO 2778.00 502.00 358
1990 DOMINION EAST OHIO 1951.00 387.00 365
1991 DOMINION EAST OHIO 1424.00 592.00 365
1992 DOMINION EAST OHIO 1309.00 280.00 365
1993 DOMINION EAST OHIO 1677.00 449.00 365
1994 DOMINION EAST OHIO 1677.00 449.00 365
1995 BELDEN & BLAKE CORPORATION 1090.00 87.00 151
1996 BELDEN & BLAKE CORPORATION 739.00 215.00 366
1997 BELDEN & BLAKE CORPORATION 797.00 326.00 330
1998 BELDEN & BLAKE CORPORATION 821.00 229.00 365
1999 BELDEN & BLAKE CORPORATION 994.00 251.00 365
2000 BELDEN & BLAKE CORPORATION 792.00 206.00 366
2001 BELDEN & BLAKE CORPORATION 985.00 228.00 358
2002 BELDEN & BLAKE CORPORATION 1022.00 275.00 358
2003 BELDEN & BLAKE CORPORATION 645.00 294.00 365
2004 BELDEN & BLAKE CORPORATION 1432.00 379.00 363
2005 BELDEN & BLAKE CORPORATION 1015.00 280.00 365
2006 BELDEN & BLAKE CORPORATION 973.00 244.00 365
2007 ENERVEST OPERATING LLC 1021.00 139.00 365
2008 ENERVEST OPERATING LLC 1122.00 215.00 365
2009 ENERVEST OPERATING LLC 1211.00 140.00 365
2010 ENERVEST OPERATING LLC 1448.00 169.00 365
2011 ENERVEST OPERATING LLC 1218.00 165.00 0
2012 ENERVEST OPERATING LLC 738.00 161.00 366
2013 ENERVEST OPERATING LLC 197.00 75.00 365
2014 ENERVEST OPERATING LLC 161.00 206.00 365
2015 ENERVEST OPERATING LLC 73.00 126.00 365
2016 ENERVEST OPERATING LLC 274.00 106.00 366
2017 ENERVEST OPERATING LLC 575.00 143.00 365
2018 ENERVEST OPERATING LLC 396.00 113.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DOMINION EAST OHIO Brine 0 0
1985 DOMINION EAST OHIO Brine 60 365
1986 DOMINION EAST OHIO Brine 40 365
1987 DOMINION EAST OHIO Brine 240 352
1988 DOMINION EAST OHIO Brine 203 319
1989 DOMINION EAST OHIO Brine 230 358
1990 DOMINION EAST OHIO Brine 126 365
1991 DOMINION EAST OHIO Brine 0 365
1992 DOMINION EAST OHIO Brine 0 365
1993 DOMINION EAST OHIO Brine 0 365
1994 DOMINION EAST OHIO Brine 0 365
1995 BELDEN & BLAKE CORPORATION Brine 0 151
1996 BELDEN & BLAKE CORPORATION Brine 2 366
1997 BELDEN & BLAKE CORPORATION Brine 0 330
1998 BELDEN & BLAKE CORPORATION Brine 10 365
1999 BELDEN & BLAKE CORPORATION Brine 12 365
2000 BELDEN & BLAKE CORPORATION Brine 44 366
2001 BELDEN & BLAKE CORPORATION Brine 9 358
2002 BELDEN & BLAKE CORPORATION Brine 8 358
2003 BELDEN & BLAKE CORPORATION Brine 33 365
2004 BELDEN & BLAKE CORPORATION Brine 110 363
2005 BELDEN & BLAKE CORPORATION Brine 33 365
2006 BELDEN & BLAKE CORPORATION Brine 43 365
2007 ENERVEST OPERATING LLC Brine 49 365
2008 ENERVEST OPERATING LLC Brine 40 365
2009 ENERVEST OPERATING LLC Brine 52 365
2010 ENERVEST OPERATING LLC Brine 29 365
2011 ENERVEST OPERATING LLC Brine 38
2012 ENERVEST OPERATING LLC Brine 38 366
2013 ENERVEST OPERATING LLC Brine 12 365
2014 ENERVEST OPERATING LLC Brine 2 365
2015 ENERVEST OPERATING LLC Brine 0 365
2016 ENERVEST OPERATING LLC Brine 0 366
2017 ENERVEST OPERATING LLC Brine 0 365
2018 ENERVEST OPERATING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1481477206 2007-12-4 0:00: PW No Violations
1135864010 2005-12-28 Production Wells No Violations The tank battery consists of 3-100 bbl storage tanks. One of which is not in use. And a dike.
1343066844 2012-07-16 Production Wells No Violations I performed an inspection on the above site and found the tank battery consists of three 100 barrel tanks and one vertical separator. The well is equipped with a pumping unit and an electric motor. Identification signs are posted. No violations at this time.
1481477206 2007-12-04 Production Wells No Violations I preformed a random field inspection. GPSd the well and the tank battery. ID sign was posted. The tank battery was in good shape. There were no violations at this time.
1534871312 2018-08-20 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-0230. RBDMS indicated reported production was current. Access to the location remained drivable and stable. The 8.625 well head was below grade. The 4.5 production casing was equipped with an electric pump jack that was operating at the time of inspection. No leaks were observed. A domestic supply connection was present. A stable earthen dike that was free of fluid was present around the production equipment. Equipment on location consisted of one (1) vertical separator and three (3) fluid tanks. The separator remained in good repair. The meter house was outside of the dike and contained a current 31 day chart. The tanks remained in good repair. Correct identification was present. Valves were plugged and closed. Staining consistent with a legacy operation was present. No violations were observed during this inspection.

For data sources see[9]

References