Well ID: 34-089-26082 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.21,"lon":-82.6,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Licking | |
Municipality: Bennington Township | |
Operator Name: KNOX ENERGY INC. | |
Well Pad ID: | |
Farm/Lease Name: RUNYON J | |
License Status: Producing | |
License Date: 2011-12-15 | |
Spud Date: 2012-03-28 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2012-04-22 | |
Well Total Depth: 2240.00 ft | |
Configuration: Vertical | |
Latitude: 40.210000 | |
Longitude: -82.600000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-12-15 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:12/15/2011, Expired Date:12/14/2013 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2012-04-22 | |
Completion Report Received | 2012-07-16 | |
Construction Permit Expires | 2013-12-14 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2012-07-23 | 2110 | 2118 | 17 |
2110 | 2118 | 17 | |
2110 | 2118 | 17 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-06-05 | H2O | 15 | 56083 Gal | 10000 | Producers Service Corporation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | KNOX ENERGY INC. | 1994.00 | 0.00 | 104 |
2013 | KNOX ENERGY INC. | 5347.00 | 0.00 | 365 |
2014 | KNOX ENERGY INC. | 4641.00 | 0.00 | 365 |
2015 | KNOX ENERGY INC. | 3876.00 | 0.00 | 365 |
2016 | KNOX ENERGY INC. | 3143.00 | 0.00 | 365 |
2017 | KNOX ENERGY INC. | 3328.00 | 0.00 | 365 |
2018 | KNOX ENERGY INC. | 3251.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | KNOX ENERGY INC. | Brine | 70 | 104 |
2013 | KNOX ENERGY INC. | Brine | 42 | 365 |
2014 | KNOX ENERGY INC. | Brine | 0 | 365 |
2015 | KNOX ENERGY INC. | Brine | 0 | 365 |
2016 | KNOX ENERGY INC. | Brine | 0 | 365 |
2017 | KNOX ENERGY INC. | Brine | 0 | 365 |
2018 | KNOX ENERGY INC. | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1502641419 | 2012-8-14 0:00: | PL | No Violations | |
-180708594 | 2018-6-25 0:00: | PW | No Violations | |
-557354555 | 2012-4-20 0:00: | DD | No Violations | |
0180708594 | 2018-06-25 | Production Wells | No Violations | The operator assisted in the collection of a water sample TSB211 for analysis from the storage tank. The specific gravity of the water was field measured at 1.14 units. |
0557354555 | 2012-04-20 | Drill / Deepen / Reopen | No Violations | I witnessed the cementing of the surface casing today. |
1502641419 | 2012-08-14 | Preliminary Restoration | No Violations | An inspection revealed that the Preliminary Restoration meets ORC 1509.072. The well is situated on a location designated as an agricultural field. A GPS reading was obtained for the well and tank locations. The well was equipped and pumping at time of inspection. The tank battery location contained an earthen dike surrounding (1) 100bbl, horizontal separator, drip and gas meter. Identification was displayed at the tank. |
For data sources see[9]